Catalog excerpts
Datasheet_KSQ332EJD1 (rev 1.0... - pdfMachine from Broadgun Software, http://pdfmachine.com, a great PDF writer utility! table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:10.00pt "Arial", sans-serif; } .font4 { font:17.00pt "Arial", sans-serif; } .font5 { font:24.00pt "Arial", sans-serif; } .font6 { font:8.60pt "Arial Black", sans-serif; } .font7 { font:11.00pt "Arial Black", sans-serif; } KSQ332EJD1 CHECK SYNCHRONISER RELAY & BUS/GENERATOR COUPLER Prcision check synchroniser, sector principle Bus & Generator coupler, Dead-bus AND/OR dead generatorfacility Bi-directional synchronising Integral voltage differential protection, adjustable "Easy view" status presentation ■ Spcifications Description KSQ332EJD1 provides both visual speed rotation, phase angel relationship and relay signal necessary to permit check synchronising of two different system voltages or as bus/generator coupler. When used as a bus/generator coupler, the CB close relay will energise when either the bus and/orthe generator is "dead" AND the enable signal is closed. The synchronising relay will close when the voltage and phase angle has been within the set limits for the set retention time. Agreen lamp will indicate the close command to the breaker. There is lamp indication for reference source present (BUS PWR) and incomer status (GEN PWR). And an additional lamp for the voltage comporator (Voltage OK), green LED is lit when gen. voltage is within voltage set limits. KSQ332EJD1 is only available with separate AC or DC auxiliary supply. Applications KSQ332EJD1 can be used both for single and three phase systems. Any two phases (also neutral) can be used for synchronising as long as it is the same two phases on both side of the breaker. The unit is meant for manual and semi-automatic synchronising only since there is no compensation for the breaker closing time. For automatic synchronising then the KSQ104 "SPOT ON" principle should be used to get compensation for the breaker closing delay. Monitored Voltage Input: 100-120,200-240, 380-415, or440-460VAC,40^70Hz Aux.Supply: AC: 100-120,200-240,380-415, or 440-460VAC 40-70Hz DC: 24Vnom(18-36VDC) or 36-160VDC Contact Rating: Adjustments: AC: 100VA-250V/2Amax. DC:50W-100V/1Amax._ High voltage limit : 2-15% of net voltage Low voltage limit : 2-15% of net voltage Phase angle :4-30degrees Retention time : 100-600mS Temperature: -20to+70°C Weight: 0.7kgs Front protection: IP54 (IP65 optional) Unit meets IEC60092-504 and relevant environmental and EMC tests specified in IEC60068/60092 and IEC61000/60533 respectively, to comply with Classification Societies requirements. Megacon is the inventor of the original, now industry standard "rotating" LED display, and a trendsetter in modern synchronisation control. User settable limits and retention time. mCQQCOn Norway - UK
Open the catalog to page 1Datasheet_KSQ332EJD1 (rev 1.0... - pdfMachine from Broadgun Software, http://pdfmachine.com, a great PDF writer utility! table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:8.00pt "Arial", sans-serif; } .font4 { font:10.00pt "Arial", sans-serif; } .font5 { font:13.20pt "Arial", sans-serif; } .font6 { font:17.00pt "Arial", sans-serif; } .font7 { font:22.00pt "Arial", sans-serif; } .font8 { font:24.00pt "Arial", sans-serif; } .font9 {...
Open the catalog to page 2All Meagacon AS catalogs and technical brochures
-
MT-VA
2 Pages
-
MT-VF
2 Pages
-
MT-AW-R
3 Pages
-
MT-FP
2 Pages
-
MT-FW/R
3 Pages
-
MXG105 LOAD UNIT
1 Pages
-
MEVx Series
1 Pages
-
MCVBx Series
1 Pages
-
MEVx-0,2 Series
1 Pages
-
MCVBx-0,2 Series
1 Pages
-
MSA11B Series
1 Pages
-
MSA11E Series
1 Pages
-
MSA12B Series
1 Pages
-
KPM30x Series
2 Pages
-
KPM303x Series
2 Pages
-
KCT3x Series
1 Pages
-
FA Frequency Meter Series
5 Pages
-
Integra Series
4 Pages
-
PQ Voltmeter Series
6 Pages
-
SADPminiEx Series
3 Pages
-
SADPmini Series
4 Pages
-
Switches F1Pxx Series
2 Pages
-
D.C. DIN Shunts
2 Pages
-
KCM165K
3 Pages
-
KPM465x
3 Pages
-
KPM26x
4 Pages
-
KPM163FQ
2 Pages
-
KPM161FQ
2 Pages
-
K R M 1 6 1 - D C
1 Pages
-
KPM 16xM
3 Pages
-
K P M 1 6 x
5 Pages
-
DC SIGNAL ISOLATOR
1 Pages
-
Voltage Comparator
1 Pages
-
SECTOR SYNCHRONISING RELAY
2 Pages
-
GENERATOR CONTROLLER
2 Pages