AC GENERATOR CURRENT DIFFERENTIAL GUARD KCC112x • Generator stator earth fault protection • Winding insulation protection • ”Pathfinder” function eases faultfinding • For use with 1A or 5A current transformers • Very fast analogue output (<50mS), (F-version) • Optional slave indicator scaled 0-40%In Specifications Standard Auxiliary Voltage: Optional Auxiliary Voltage: Current Input:: Contact rating: Adjustments: Warning: Alarm: Analogue outputs: F-versions 100-120, 200-240, 380-415 or 440-460VAC, 40-70Hz (Fuse 2A) 1 or 5A C.T. (Class 0,5 or better) AC: 100VA - 250V/2A max. DC: 50W - 100V/1A max. Trip level: Delay: 0-100% of alarm level 0-30 sec. 0-40% of I nom. 0-3 sec. Up to 20mA, max 500ohm Up to 10V, min 10kohm KCC112E protects against phase-, earth- and winding faults within the protected area (the stator) of large AC generators. It detects even minute insulation punctures, flash-over carbon deposits and contamination. The unit measures highest up differential current from antiparallelled CTs in a Merz-Price configuration, by comparing current levels at the end of each phase winding. R1 is used for early warning. R2 or R3 (fail safe) is to be used for generator breaker trip, the "other" alarm relay can be used for local indication input to PMS, alarm system etc. Alarm trip must be set sufficiently high to ensure that generator magnetisation current does not cause tripping. The alarm delay is to be set so that the initial inrush current have returned to normal level before the delay period elapses. The warning trip level and delay can be set as required to give early warning. Temperature: Weight: Front protection: User settable trip levels and delays. Colour of LEDs indicates alarm status. LEDs flash during count-down. The meter and the triple-zone status LEDs at a glance gives the clear safety message: ALARM/ WARNING/NORMAL The F-versions have an fast response mAoutput signal proportional to highest up current. The "Pathfinder" function identifies the phase(s) causing the trip by the flashing pattern of the relevant LED(s). The unit meets IEC60092-504 and the relevant environmental and EMC tests specified in IEC60068/60092 and IEC61000/60533 respectively, to comply with the requirements of the major Classification Societies. Generator stator Merz - Price configuration Fail safe Relay Reset Any latched relay is reset by linking terminals 12 and 13. KCC112x Cabel with RJ12 plug Megacon reserves the right to make any changes to the information at any time Relays shown de-energised, a fail-safe relay energises when the unit is powered. Optional slave indicator with LEDs (DIN96)
Open the catalog to page 1All Meagacon AS catalogs and technical brochures
-
MT-VA
2 Pages
-
MT-VF
2 Pages
-
MT-AW-R
3 Pages
-
MT-FP
2 Pages
-
MT-FW/R
3 Pages
-
MXG105 LOAD UNIT
1 Pages
-
MEVx Series
1 Pages
-
MCVBx Series
1 Pages
-
MEVx-0,2 Series
1 Pages
-
MCVBx-0,2 Series
1 Pages
-
MSA11B Series
1 Pages
-
MSA11E Series
1 Pages
-
MSA12B Series
1 Pages
-
KPM30x Series
2 Pages
-
KPM303x Series
2 Pages
-
KCT3x Series
1 Pages
-
FA Frequency Meter Series
5 Pages
-
Integra Series
4 Pages
-
PQ Voltmeter Series
6 Pages
-
SADPminiEx Series
3 Pages
-
SADPmini Series
4 Pages
-
Switches F1Pxx Series
2 Pages
-
D.C. DIN Shunts
2 Pages
-
KCM165K
3 Pages
-
KPM465x
3 Pages
-
KPM26x
4 Pages
-
KPM163FQ
2 Pages
-
KPM161FQ
2 Pages
-
K R M 1 6 1 - D C
1 Pages
-
KPM 16xM
3 Pages
-
K P M 1 6 x
5 Pages
-
DC SIGNAL ISOLATOR
1 Pages
-
Voltage Comparator
1 Pages
-
SECTOR SYNCHRONISING RELAY
2 Pages
-
GENERATOR CONTROLLER
2 Pages