V-Cone
6Pages

{{requestButtons}}

Catalog excerpts

V-Cone - 1

In Real World Measurement Applications Ideal For Tough Applications Advanced Differential Pressure flow meter Technology T he McCrometer V-Cone flow meter technology accurately measures flow over a wide range of Reynolds numbers, under all kinds of conditions and for a variety of fluids. It operates on the same physical principle as other differential pressure-type flow meters, using the theory of conservation of energy in fluid flow through a pipe. The V-Cone flow meter’s remarkable performance characteristics, however, are the result of its unique design. It features a centrally-located cone inside the tube. The cone interacts with the fluid Advanced DP flow, reshaping the fluid’s flow profile and creating a region of lower pressure immediately Technology: downstream of itself. The pressure difference, Principles of exhibited between the static line pressure and Operation the low pressure created downstream of the cone, can be measured via two pressure sensing taps. One tap is placed slightly upstream of the cone, the other is located in the downstream face of the cone itself. The pressure difference is then incorporated into a derivation of the Bernoulli equation to determine the fluid flow rate. The cone’s central position in the line optimizes the velocity of the flow at the point of measurement, assuring highly accurate, reliable flow measurement regardless of the flow condition upstream of the meter. oil & gas production and delivery • petroleum refining • municipal water & wastewater • chemical/ pharmaceutical processing • power/co-generation • mining • pulp & paper • industrial manufacturing • food & beverage Standard Accuracy: From ± 0.5% of actual flow (certain fluids and Reynolds number applications require special calibrations to achieve this value). Repeatability: Flow Ranges: Standard Beta Ratios: Head Loss: Installation Piping Requirements: ±0.1% or better. 10:1 and greater. 0.45 through 0.80, special betas available. Varies with beta ratio and DP. Typically 0-3 diameters upstream and 0-1 diameters downstream of the cone are required, depending on fittings or valves in the adjacent pipeline. Materials of Construction Include: Duplex, 304, or 316 stainless steel, Hastelloy C-276, 6MO, carbon steels. Other materials on request. Line Sizes: 0.5” to 120” or larger. End Fittings: Flanged, threaded, hub or weld-end standard. Others on request. Configurations: Precision flow tube and wafer-type. • • Approvals for the V-Cone Flow Meter: • • • Performance Verification Testing • Calibrated for customer application. ASME B31.3 construction standard. Canadian custody transfer approved. Meters in compliance with PED97/23/EC are available upon request. ISO 9001:2008 certified quality management system. Tested at an API Registered MPMS Test Facility according to the requirements of API MPMS Chapter 22.2. www.mccrometer.com 3255 West Stetson Avenue, Hemet, California 92545 USA Phone 800-220-2279 | 951-652-6811 | Fax 951-652-3078 © 2009-2012 by McCrometer, Inc. / Printed in USA Lit Number 24509-49 Rev. 2.2 / 06-12 May be covered by one or more patents, including U.S. Patents 5,363,699 and 5,814,738 and counterparts outside the U.S.; other U.S. and foreign patents pending. V-Cone® and Wafer-Cone® are registered trademarks of McCrometer, Inc. For The Real World.

Open the catalog to page 1
V-Cone - 2

The V-Cone® flow meter - A Superior DP Technology Proven Performance - More than 70,000 Meters - 25+ Years Experience The V-Cone Flow meter typically requires only 0-2 pipe diameters even in disturbed flow applications. Centrally-located cone directs flow to the outside wall effectively conditioning disrupted flows. High Performance in “Real World” Applications Accuracy You Can Count On Acts As Own Flow Conditioner Maximum Installation Flexibility cCrometer’s V-Cone® flow meter is an innovative system that takes differential pressure flow measurement to another level. Designed for mild to...

Open the catalog to page 2
V-Cone - 3

The V-Cone® flow meter - A Superior DP Technology Proven Performance - More than 70,000 Meters - 25+ Years Experience The V-Cone Flow meter typically requires only 0-2 pipe diameters even in disturbed flow applications. Centrally-located cone directs flow to the outside wall effectively conditioning disrupted flows. High Performance in “Real World” Applications Accuracy You Can Count On Acts As Own Flow Conditioner Maximum Installation Flexibility cCrometer’s V-Cone® flow meter is an innovative system that takes differential pressure flow measurement to another level. Designed for mild to...

Open the catalog to page 3
V-Cone - 4

The V-Cone® flow meter - A Superior DP Technology Proven Performance - More than 70,000 Meters - 25+ Years Experience The V-Cone Flow meter typically requires only 0-2 pipe diameters even in disturbed flow applications. Centrally-located cone directs flow to the outside wall effectively conditioning disrupted flows. High Performance in “Real World” Applications Accuracy You Can Count On Acts As Own Flow Conditioner Maximum Installation Flexibility cCrometer’s V-Cone® flow meter is an innovative system that takes differential pressure flow measurement to another level. Designed for mild to...

Open the catalog to page 4
V-Cone - 5

In Real World Measurement Applications Ideal For Tough Applications Advanced Differential Pressure flow meter Technology T he McCrometer V-Cone flow meter technology accurately measures flow over a wide range of Reynolds numbers, under all kinds of conditions and for a variety of fluids. It operates on the same physical principle as other differential pressure-type flow meters, using the theory of conservation of energy in fluid flow through a pipe. The V-Cone flow meter’s remarkable performance characteristics, however, are the result of its unique design. It features a centrally-located...

Open the catalog to page 5
V-Cone - 6

In Real World Measurement Applications Ideal For Tough Applications Advanced Differential Pressure flow meter Technology T he McCrometer V-Cone flow meter technology accurately measures flow over a wide range of Reynolds numbers, under all kinds of conditions and for a variety of fluids. It operates on the same physical principle as other differential pressure-type flow meters, using the theory of conservation of energy in fluid flow through a pipe. The V-Cone flow meter’s remarkable performance characteristics, however, are the result of its unique design. It features a centrally-located...

Open the catalog to page 6

All McCrometer catalogs and technical brochures

  1. FPI Mag

    4 Pages

  2. Scotchkot

    4 Pages

  3. Level Sensor

    2 Pages

  4. WHITE PAPER

    5 Pages

  5. Ultra Mag

    4 Pages

  6. Wafer-Cone

    4 Pages

  7. V2

    4 Pages

Archived catalogs