LVS-301

LVS-301

LVS-301

Product catalog summary
Introduction
The LVS-301 is a linearized velocity sensor designed by MC-monitoring SA for low-frequency vibration monitoring in rotating machines, particularly suitable for low-speed hydroelectric machines. It features a frequency response down to 0.5Hz and includes built-in linearization micro-electronics for amplitude and phase compensation.

Features
  • Frequency response down to 0.5Hz.
  • Built-in linearization for low-frequency compensation.
  • Models available for horizontal and vertical mounting.
  • Stainless steel body with dynamic signal carried on DC bias voltage.
  • Available with push-pull connector or integral cable.

Operation
  • Sensitivity: 100mV/mm/s ±5% (Vertical).
  • Transverse sensitivity: < 7% max.
  • Horizontal vs Vertical sensitivity: 0.5-28Hz < +10%, 28-1500 Hz < +2%.
  • Maximum displacement: 1.52mm peak-peak.
  • Natural frequency: 28Hz typ., Resonance Frequency: >4kHz.
  • Output: Linearized and raw with impedance of 100Ω.
  • Output bias voltage: +12V or +6V for +24VDC / -12V or -6V for -24VDC.
  • Temperature coefficient: 0.1%/°C.
  • Power: +24VDC ±10% or -24VDC ±10% (approx. 15mA).

Environmental Specifications
  • Operating temperature: -20° to +80°C.
  • Storage temperature: -40° to +80°C.
  • Humidity: Resistant to 100% RH.
  • Shock limit: 50g, Continuous vibration: 5g.
  • EMC: Compliant with EN 61326-2-3:2006.
  • Ingress Protection: IP68 as per DIN 40 050.

Physical Specifications
  • Dimensions: ø42 x 84 mm.
  • Body material: Stainless steel 1.4313.
  • Weight: 450g.
  • Output cable: ø5mm cable with top radial exit via push-pull connector or cable gland with ø10mm flexible metal conduit covered by PVC IP68.
  • Mounting stud: M10x1.5, length 20mm, stainless steel or adapter in option.

Field Wiring
  • Termination color coding for +24VDC and -24VDC versions.

Ordering Information
  • Ordering code: 05.301.028 C Y L.
  • C - Cable Options: 1 for Integral cable, 3 for Push-pull connector.
  • Y - Power supply options: 0 for +24V / +12V Bias, 1 for -24V / -12V Bias, 2 for +24V / +6V Bias, 3 for -24V / -6V Bias.
  • L - Extension cable length: 5m or 10m.

Contact Information
MC-monitoring SA, Route André Piller 19, CH-1762 Givisiez, Switzerland. Phone: +41 58 411 54 00, Email: [email protected], Web: mc-monitoring.com.
See more

Catalog excerpts

LVS-301-1

Linearized Velocity Sensor LVS-301 Omnidirectional Monitoring solution Frequency response down to 0.5Hz Built-in linearization micro-electronics circuit for low fre- Shaft & bearing vibration absolute quency amplitude and phase compensation • Models for horizontal and vertical mounting positon Stainless steel body Dynamic signal carried on DC bias voltage Push-Pull Connector or integral cable Typical applications Hydrogenerators Pumps, fan, cooling towers... Gas & steam turbines DESCRIPTION The LVS-301 velocity sensors have been designed for low frequency vibration monitoring applications of rotating machines. More specifically, the sensors fulfil the special low frequency requirements of very low speed hydroelectric machines. The LVS sensors operate in accordance with the electrodynamic principle and are used for measuring the bearing absolute vibration of the machines. The sensing element of the sensor is a coil supported by high precision springs moving around a permanent magnet which produces a voltage directly proportional to the vibration velocity. By design, the sensor has an excellent sensitivity and linearity down to very low vibration levels. The built-in electronics allows the sensor to accurately monitor vibration frequency down to 0.5Hz. The sensor provides two voltage outputs proportional to the vibration velocity : • A raw output corresponding to buffered non-linearized signal • The low frequency linearized vibration signal for monitoring purposes down to 0.5 Hz • The sensor can be powered with +24VDC or -24VDC depending on the ordered version. The sensor can be wired by push-pull connector (C3), so the extension cable can be detached during installation. Or by integral cable (C1).

 Open the catalog to page 1
LVS-301-2

GLOBAL SPECIFICATIONS OPERATION Sensitivity Transverse sensitivity Horizontal vs Vertical sensitivity Maximum displacement Natural frequency Resonance Frequency Output Impedance Output bias voltage Output bias voltage tolerance Maximum output voltage Temperature coefficient Typical frequency response at 2mm/s Analog band pass filter Power 100mV/mm/s ±5% (Vertical) < 7% max. of nominal 0.5-28Hz < +10%, 28-1500 Hz < +2% 1.52mm peak-peak 28Hz typ. >4kHz Linearized Raw 100Q + 12V or +6V for +24Vdc / -12V or -6V for -24Vdc ±5% of bias voltage 10V peak for 12V bias / 5V peak for 6V bias 0.1%/°C (<0.3%/°C...

 Open the catalog to page 2
LVS-301-3

MECHANICAL DRAWING

 Open the catalog to page 3
LVS-301-4

ORDERING INFORMATION Ordering code 05.301.028 C Y L C - Cable Options 1 Integral cable 3 Push-pull connector L - extension cable length 5m 10m Part Stud M10 to M8 Stud M10 to M6 Temporary mounting magnet : See PMH-140 MC-monitoring Quality certifications LOCAL REPRESENTATIVE MC-monitoring SA Route Andre Piller 19 CH-1762 Givisiez | Switzerland Phone : +41 58 411 54 00 Mail : [email protected]

 Open the catalog to page 4

All MC-monitoring SA catalogs and technical brochures

  1. SPS Datasheet

    11  Pages

  2. PMM-300P Rhino

    10  Pages

  3. CPP

    4  Pages

  4. RTM-200

    4  Pages

  5. MFT-100

    4  Pages

  6. SPP-201

    3  Pages

  7. RCP-004

    3  Pages

  8. PAS-138

    3  Pages

  9. FAS M2

    3  Pages

  10. FAS M5

    3  Pages

  11. FAS-200

    3  Pages

  12. CMS-500P Orca

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.