Air Gap Transducer - 3G technology AGT-3G Monitoring solution Embedded Digital Signal processing High-speed grade FPGA 6x300 MHz. Active Temperature compensation High accuracy and repeatability. Advanced algorithm for noise rejection Increased immunity to electrical disturbances IN/OUT Galvanic separation. Immunity to strong magnetic field Typical applications Hydrogenerators Gearless millsdrives DESCRIPTION The dynamic air gap monitoring of generators consists of the distance measurement between rotor poles and stator while it is in operation. The MCm AGT range of air gap sensors are a non-contact dynamic position transducer utilising a capacitive technique to provide an accurate displacement measurement from the sensor face to a metal target. The advantage of the capacitive technique in generator applications is the high immunity to magnetic fields; the AGT series also provides high resolution and relative insensitivity to different (metal) target materials. Typical contact-free capacitive Air Gap Transducer (AGT) is composed of 3 elements. It features separate Sensor (AGS), the Air Gap Oscillator (AGO) and the Demodulator (AGD). Demodulator The demodulator provides three signal outputs : 1 • MinGap voltage (V) • Pole Profile voltage (V) 1 • Pole Profile or MinGap current (mA) All outputs are galvanically isolated and the current output is factory set on Pole Profile. The digital technology combined with high performance noise rejection filters allow a linearization adjusted with great accuracy and resolution, with stable and repetitive behaviours. Industrial metal housing enables installation in harsh environments. Sensor and Oscillator Designed for long life cycles, harsh environments and strong magnetic fields. The sensor shape is suitable for its installation on the stator wall of generators and motors. 1 See user manual for detailed description
Open the catalog to page 1MEASURING RANGES OVERVIEW
Open the catalog to page 2mcmonitoring AGT-212 3G SPECIFICATIONS AGD-212 M4 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error AGD-212 M5 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error AGD-212 M7 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error AGD-212 M8 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average...
Open the catalog to page 3TRANSDUCER OVERVIEW
Open the catalog to page 4Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error PHYSICAL [mm] Sensor surface 385 x 20 x 3.5 LxWxH Sensor interface MCX coaxial plug Conditioner module dimensions 170 x 63 x 40 LxWxH TRANSDUCER OVERVIEW AirGap Demodulator (AGP) Flexible metal conduit SPR-AS AirGap Oscillator (AGO) AGO grounding wire AGT-3G _Datasheet.pub © MC-monitoring SA / 2024-01-16 / English Page 5
Open the catalog to page 5AGT-525 3G SPECIFICATIONS AGD-525 M1 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error AGD-525 M2 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error PHYSICAL [mm] Sensor surface 221 x 32 x 3.5 LxWxH Sensor interface MCX coaxial plug Conditioner module dimensions 170 x 63 x 40 LxWxH TRANSDUCER OVERVIEW AirGap Demodulator (AGP) Flexible metal conduit SPR-AS
Open the catalog to page 6AGT-530 3G SPECIFICATIONS AGD-530 M3 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error PHYSICAL [mm] Sensor surface Sensor interface AGO-2xx dimensions Conditioner module dimensions 5 to 30mm (0.2 to 1.18 in) 0.32V/mm 0.64mA/mm < 3.5% of reading from 11mm to 29mm < 5.0% of reading from 5mm to 30mm < 0.8% 221 x 32 x 3.5 LxWxH LEMO triaxial plug (AGS-525 M4) 016x100 170 x 63 x 40 LxWxH
Open the catalog to page 7AGD-550 M1 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error AGD-550 M2 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error AGD-550 M3 Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error PHYSICAL [mm] Sensor surface Sensor interface Adapter module dimensions Conditioner module dimensions 5 to 50mm (0.2 to 1.96 in) 0.178V/mm 0.355mA/mm < 4.2% of reading...
Open the catalog to page 8AGT-550MX 3G SPECIFICATIONS AGD-550 MX Linear measuring range Voltage outputs sensitivity Current outputs sensitivity Max. dev. from straight line Average linearity error PHYSICAL [mm] Sensor surface Sensor interface Adapter module dimensions Conditioner module dimensions 263 x 80 x 3.5 LxWxH MCX coaxial plug 120 L x 025 170 x 63 x 40 LxWxH TRANSDUCER OVERVIEW AirGap Demodulator (AGP) Flexible metal conduit SPR-AS
Open the catalog to page 9mcmonitoring AGT 3G HT SPECIFICATIONS (High Temperature applications) AGD-105 M1 Linear measuring range
Open the catalog to page 10AGT 3G HT SPECIFICATIONS (High Temperature applications)TRANSDUCER OVERVIEW AirGap Demodulator (AGD1 F exib e meta conduit SPR-AS Flexible metal conduit SPR-AS
Open the catalog to page 11OPERATION Output function Output range Loop resistance (current output) Output resistance (voltage outputs) AGD-xxx Mx temperature coefficient AGO-xxx M3 temperature deviation max. Typical frequency response (-3dB) Output noise Interchangeability tolerance Power Voltage Current consumption Sensor (AGS) triaxial cable length AGS-212 M4, M5, M6: AGS-520 M2: AGS-525 M3, M4: AGS-550 M3: AGS-550 MX: ENVIRONMENTAL Temperature range : Operation Temperature range (HT models) : Operation Long term storage (all models) : Ingress protection (acc. to EN60529) Relative humidity (non-condensing) Intended...
Open the catalog to page 12ORDERING INFORMATION List Of Parts Numbers: Output range
Open the catalog to page 13ORDERING INFORMATION Standardized CoMPREHENSiVE Systems MC-monitoring Quality certifications LOCAL REPRESENTATIVE MC-monitoring SA Route Andre Piller 19 | PO BOX 97 CH-1762 Givisiez | Switzerland Phone : +41 58 411 54 00 Mail : info@mc-monitoring.com
Open the catalog to page 14All MC-monitoring SA catalogs and technical brochures
-
PMM-300P Rhino
10 Pages
-
PMM-305
7 Pages
-
CPP
4 Pages
-
RTM-200
4 Pages
-
MFT-100
4 Pages
-
SPP-201
3 Pages
-
RCP-004
3 Pages
-
RCP-008 & RCP-010
3 Pages
-
LVS-301
4 Pages
-
LVS-101 / LVS-201
4 Pages
-
PAS/PVS Cable Assembly
8 Pages
-
PAS-138
3 Pages
-
FAS Cable Assembly
5 Pages
-
FAS M2
3 Pages
-
FAS M5
3 Pages
-
FAS-200
3 Pages
-
PPT-120
3 Pages
-
PPT-280 - Eagle
4 Pages
-
PPT-080 & PPT-110
5 Pages
-
PPT-380 - Eagle
4 Pages
-
PPT-480 - Eagle
3 Pages
-
PMS-300P Rhino
13 Pages
-
CMS-500P Orca
5 Pages
-
SCD-200
3 Pages
-
DRS-020
3 Pages
-
PMS-391
3 Pages