video corpo

OXY-PILOT® Natural Gas Burners
2Pages

{{requestButtons}}

Catalog excerpts

OXY-PILOT® Natural Gas Burners - 1

OXY-THERM® Accessories Page 4675 3/99 Maxon Oxy-pilot Oxy-pilot Specifications Fuel Flow Pressure Capacity Natural Gas 25 CFH 2.25" wc 25,000 Btu/hr Propane 10 CFH 0.83" wc Oxygen 53 CFH 0.5" wc 12.25 (approximate) 1/2" NPT 2.25 Clearance for Removal Oxy Inlet (1/2" NPT) Ignition Transformer Connection Natural Gas Inlet (3/16" O.D. Tube) NOTE: Swagelock fitting can be removed for 1/8" NPT attachment Dimensions (in inches)

Open the catalog to page 1
OXY-PILOT® Natural Gas Burners - 2

Page 4676 OXY-THERM® Accessories Maxon Oxy-pilot Ignition Maxon recommends the use of a 6000 volt fullwave spark ignition transformer for use with the Oxypilot. A standard .250" female spade connector should be used on the ignition transformer connection. The Insulator Block helps reduce stray voltages that may migrate back up the fuel line and/or damage any sensitive electronic equipment and must not be removed. Installation and Start-up • The pilot is shipped “cleaned for oxygen service.” The spark gap is factory-set. Never attempt to disassemble the pilot. • Install the pilot by the NPT...