1. Catalogs
  2. Maximator GmbH
  3. Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5
video corpo

Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5

Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5
1 / 52 PagesView full catalog

Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5

Product catalog summary
General Information
This manual provides comprehensive instructions for the installation and operation of MAXIMATOR air amplifiers, specifically models MPLV4, MPLV7, SPLV3, SPLV10, and GPLV5. It emphasizes the importance of adhering to the manual for safe and effective use, detailing order codes, rating plates, and symbols used throughout the document.
Safety and Protection Measures
Essential safety measures are outlined, including the use of personal protective equipment (PPE) and maintaining clear labels on the equipment. The manual stresses that only qualified personnel should handle the equipment to prevent hazards.
Product Description
The air amplifiers are designed for transporting and compressing pressurized air and nitrogen. The manual specifies intended use and warns against misuse, providing technical specifications such as operating conditions, dimensions, and performance values.
Installation
Detailed instructions for installing the air amplifier and connecting lines are provided, including the connection of drive air, control air, inlet and outlet lines, and the installation of an exhaust silencer.
Operation
The manual describes prerequisites for operation, normal and safe operation procedures, and handling abnormal situations. It also guides recognizing signs indicating the product is no longer safe to use.
Maintenance
Maintenance intervals and tasks are outlined, including system inspection, leak testing, and cleaning. Information on spare parts, consumables, and customer service is also provided.
Troubleshooting
Common issues on the drive and high-pressure sides are addressed with troubleshooting steps.
Removal and Disposal
Guidelines for the safe removal and disposal of the air amplifier are provided.
Use in Explosion-Prone Zones
Specific instructions for operating and maintaining the air amplifier in potentially explosive environments are included, emphasizing adherence to safety guidelines to prevent ignition hazards.
Specifications and Design
The document outlines the design and function of air amplifiers, which operate similarly to pressure intensifiers. Key components include air pistons, high-pressure pistons, and spool valves, facilitating the compression of operating fluids.
Safety and Risk Assessment
Potential hazards such as asphyxiation, unexpected restarts, noise-induced injuries, and risks from raised particles or ice crystals are identified. Regular risk assessments and corrective actions like ensuring adequate ventilation and regular leak checks are recommended.
Operating Conditions
The air amplifiers are designed to work with compressed air and nitrogen, with specific temperature and pressure limits. Purity requirements for operating and drive fluids adhere to ISO 8573-1 standards.
Installation and Maintenance
Installation prerequisites include ensuring the product is undamaged and accessible. Maintenance involves assessing leakage rates and ensuring the correct operation of seals and valves.
Transport and Storage
Guidelines for packaging and storage are provided to prevent damage and corrosion, advising storage in a dry, dust-free environment away from corrosive fluids and sunlight.
Performance and Service Life
Performance values are detailed on the rating plate and general drawing, with service life dependent on usage conditions. Permissible leakage rates and stroke volumes for different models are provided.
Installation and Connection
Installation procedures emphasize using screws or bolts with a minimum strength of 4.6, with a preferred vertical installation position. Specifications for connections must be followed as per the general drawing.
Commissioning
Before commissioning, ensure the product is undamaged, securely attached, and all connections are correctly installed. Permissible pressures must not exceed the maximum operating pressure.
Operation
For safe operation, the product must be free of damage, securely attached, and not subject to excessive vibrations. A risk assessment should be conducted, and all health and safety requirements met.
Maintenance
Regular maintenance is crucial, with intervals based on 1,300,000 strokes/year. Activities include system inspection, leak-testing, and cleaning.
Troubleshooting
The document provides a troubleshooting guide for common faults, such as the air amplifier not operating at low air pressure due to high friction of O-rings or incorrect lubricant use.
Removal and Disposal
Guidelines for safely removing and disposing of air amplifiers are provided, emphasizing the use of protective gear and ensuring the product is in a safe state before removal.
Use in Explosion-Prone Zones
The document details the use of compressors in explosion-prone areas, highlighting the importance of ATEX labeling and compliance with temperature and equipment protection standards.
Summary of Ignition Hazards
A table summarizes ignition hazards, sources, causes, and protective measures, including temperature class definitions and static electricity management.
Appendix
The appendix includes EU Declarations of Conformity and descriptions of safety requirements, addressing various safety and occupational health standards.
See more

Catalog excerpts

Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5-1

Maximum Pressure. Installation and operating manual

 Open the catalog to page 1
Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5-2

Key information! Follow the manual for safe and proper use. Keep the manual near the machine for later reference. MAXIMATOR GmbH Lange Straße 6 99734 Nordhausen Germany Phone: +49 3631 9533-0 e-mail: [email protected] Internet: www.maximator.de Warranty and liability: As a general rule, the “General Terms and Conditions” of Maximator GmbH shall apply. These terms and conditions are available at http://www.maximator.de. Warranty and liability claims shall not be accepted if they can be attributed to one or more of the causes mentioned in this manual or explicitly stipulated below: – – – – – –...

 Open the catalog to page 2
Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5-3

General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Information regarding this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Order code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rating plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . List of abbreviations and formula signs used . . . . . . . . ....

 Open the catalog to page 3
Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5-4

Prerequisites for installation . . . . . . . . . . Air amplifier installation . . . . . . . . . . . . . Installation of connecting lines. . . . . . . . . Connecting the drive air . . . . . . . . . . . . . Control air connection . . . . . . . . . . . . . . . Connecting the inlet line and outlet line . . Connecting a separate bleed pipe . . . . . . Exhaust silencer installation . . . . . . . . . . . Commissioning . . . . . . . . . . . . . . . . . . . . Prerequisites for commissioning . . . . . . . Commissioning . . . . . . . . . . . . . . . . . . . . Prerequisites for operation . . . . . . . ....

 Open the catalog to page 4
Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5-5

Prerequisites for removal and disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation and maintenance . . . . . . . . . . . . ....

 Open the catalog to page 5
Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5-6

General information Information regarding this manual The pneumatically driven air amplifier manufactured by MAXIMATOR is a selfcontrolling, oscillating pressure booster and is used for transporting and compressing pressurised air and nitrogen. These instructions are applicable for the air amplifier models MPLV4, MPLV7, SPLV3, SPLV10 and GPLV5 (only referred to as "compressor" in other sections and chapters) and with a serial number of greater than 23000001. The general drawing supplied along the models is an integral component of these instructions and must be kept in safe custody along with...

 Open the catalog to page 6
Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5-7

Rating plate The rating plate is located on the pneumatic cylinder of the compressor and contains the following information:1: 1 Max. permitted operating pressure 2 Air amplifier 3 Type (specifications from the order code) 4 Maximum drive pressure 5 Minimum inlet pressure 6 Calendar week/year of manufac ture 7 Article number 8 Serial number 9 Gear ratio 10 Manufacturer contact information 11 Label according to applied guidelines 12 Operating temperature range 1 Individual compressors may have different rating plates, e.g. metal ones

 Open the catalog to page 7
Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5-8

Explanation of symbols DANGER This combination of symbol and signal word indicates a hazardous situation which - if not avoided - may lead to severe injuries or death. WARNING This combination of symbol and signal word indicates a potentially hazardous situation which - if not avoided - may lead to severe injuries or death. CAUTION This combination of symbol and signal word indicates a potentially hazardous situation which - if not avoided - may lead to light or minor injuries. NOTICE This combination of symbol and signal word indicates a potentially hazardous situation which - if not avoided...

 Open the catalog to page 8
Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5-9

List of abbreviations and formula signs used Abbreviation

 Open the catalog to page 9
Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5-10

Qualification of the personnel Only qualified personnel who are specialised and have been trained to do so must work on the air amplifier. Allowing unqualified personnel to work on the compressor or enter the danger zone creates hazards which could lead to death, severe injuries and significant property damage.

 Open the catalog to page 10
Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5-11

Safety and protection measures The following sections stipulate the residual risks associated with the product, even when used as intended. In order to reduce the risk of personal injuries and material damage, and to prevent hazardous situations, you must observe the safety information listed in this section and the warnings in all other sections of this manual. Personal protective equipment Personal protective equipment (in other sections also referred to as PPE) protects personnel from occupational safety and health hazards while at work. Wearing personal protective equipment may be required...

 Open the catalog to page 11
Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5-12

During assessment, check the following leak points: Tab. 2-2 leak point danger zone The hazards are primarily due to the high pressure and extreme temperatures of the conveyed fluid and/or the hazardous substances used. The system designer must determine detailed danger zones as part of his job and can use his special knowledge of high-pressure technology and the hazardous substances used in each case.

 Open the catalog to page 12
Installation and operating manual Air amplifier - MPLV4, MPLV7, SPLV3, SPLV10, GPLV5-13

Safety and protection measures 2.4 Non obvious hazards Using asphyxiant operating fluids can lead to severe injuries or death by asphyxiation. Assess the risk for the equipment in the risk assessment. The following are some potential corrective actions: – – – – Operate the compressor in an adequately ventilated space. Check the compressor for leaks on a regular basis. Ensure that lines are connected in such a way as to remain leak-tight for a long time. If necessary, use connecting lines to remove the escaping operating fluids. Assess the risk for the equipment in the risk assessment. Residual...

 Open the catalog to page 13

Archived catalogs

  1. MO12

    2  Pages

  2. ROB 8-37

    2  Pages

  3. ROB 5-30

    1  Page

  4. GSF60

    3  Pages

  5. GSF10

    3  Pages

  6. GSF100

    3  Pages

  7. ROB 22 (-HL)

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.