1. Catalogs
  2. Maximator GmbH
  3. Installation and operating manual Air Amplifier - MPLV2, SPLV2, GPLV2

Installation and operating manual Air Amplifier - MPLV2, SPLV2, GPLV2

Installation and operating manual Air Amplifier - MPLV2, SPLV2, GPLV2
1 / 48 PagesView full catalog

Installation and operating manual Air Amplifier - MPLV2, SPLV2, GPLV2

Product catalog summary
General Information
The manual provides guidelines for the safe use of MAXIMATOR's pneumatically driven air amplifier models MPLV2, SPLV2, and GPLV2. These devices are designed to compress air and nitrogen without oil and are applicable to compressors with serial numbers above 23000001. A general drawing accompanies the instructions.

Warranty and Liability
Warranty claims are governed by Maximator GmbH's General Terms and Conditions and are void if the product is misused or maintenance instructions are ignored.

Safety and Protection Measures
Users must follow safety instructions to prevent injury and property damage. Personal protective equipment (PPE) is required, and product labels must remain legible. Users should assess the danger zone around the product due to high pressure and extreme temperatures.

Product Description
The air amplifier is intended for specific uses, and misuse can lead to hazards. It includes various ports and technical specifications, such as operating conditions and performance values.

Installation
Installation requires connecting drive air, control air, and inlet/outlet lines. Proper commissioning is crucial for safe operation.

Operation
Safe operation involves adhering to prerequisites and recognizing signs of abnormal situations. The product must be put in a safe state if it becomes unsafe to use.

Maintenance
Regular maintenance includes system inspections, leak testing, and cleaning. Spare parts and customer service information are provided.

Troubleshooting
Guidance is provided for addressing issues on both the drive and high-pressure sides of the air amplifier.

Removal and Disposal
Instructions for safe removal and disposal of the product are included, ensuring compliance with environmental regulations.

Use in Explosion-Prone Zones
Special instructions are provided for operating the air amplifier in potentially explosive environments, including temperature class and maintenance requirements.

Summary of Ignition Hazards
The manual concludes with a summary of potential ignition hazards associated with the product.
Risk Assessment and Safety Measures
The document outlines potential risks associated with the operation of compressors, including asphyxiation, unexpected restarts, noise, and hazardous operating fluids. It emphasizes the importance of conducting a thorough risk assessment and suggests corrective actions such as ensuring adequate ventilation and regular leak checks.

Residual Risks
Residual risks include the lack of a safe shut-down command device, which could lead to severe injuries or death. The document advises assessing these risks during the risk assessment process.

Product Description
The air amplifier's design and function are described, highlighting its operation similar to a pressure intensifier. The document provides a schematic diagram and explains the role of various components.

Intended Use and Misuse
The air amplifiers are intended for compressing air and nitrogen within technical limits. Misuse includes unauthorized modifications or using the product for sealing containers.

Technical Specifications
The document specifies operating conditions, including ambient temperature ranges and requirements for drive and operating fluids.

Transport, Packaging, and Storage
Guidelines for transport, packaging, and storage are provided to prevent damage and ensure the product's integrity.

Installation
Installation prerequisites include ensuring the product is damage-free and accessible. The document provides instructions for connecting drive air, control air, and inlet/outlet lines.

Commissioning
Before commissioning, all connections and lines should be checked for proper installation and damage.
Operation
  • Prerequisites for Operation: Ensure the product is undamaged, securely attached, and free from excessive vibrations.
  • Normal, Safe Operation: Ensure the product is at ambient temperature to avoid injury from extreme temperatures.
  • Abnormal Situations: Refer to system documentation for measures during abnormal operation.
  • Signs of Unsafe Use: Indicators include leakage through seals, visible damage, and leaking connections.
  • Safe State: Depressurize the air amplifier on both drive and high-pressure sides.
Maintenance
  • Intervals: Regular checks and maintenance are necessary, with intervals adjusted based on usage conditions.
  • Maintenance Work: Includes system inspection, leak testing, cleaning, and checking fasteners and connections.
  • System Inspection: Weekly checks for proper function, including pressure tests and visual inspections.
  • Leak Testing: Weekly checks using leak detection spray.
  • Cleaning: Quarterly cleaning with solvent-free products.
  • Repair: As needed, with specific guidelines for disassembly, cleaning, and reassembly.
  • Spare Parts: Use only Maximator-specified parts to avoid injury.
Troubleshooting
  • Drive Side Issues: Common faults include high O-ring friction, incorrect lubricant use, and inadequate control air pressure.
  • High Pressure Side Issues: Faults include check valve failure and worn O-rings.
Removal and Disposal
  • Prerequisites: Ensure the product is in a safe state and at ambient temperature before removal.
  • Disposal: Return the product to Maximator for proper disposal.
Use in Explosion-Prone Zones
  • General Information: Devices with ATEX labels are intended for use in specific explosive atmospheres, with details provided on the rating plate.
Temperature Class
The temperature of the compressor is influenced by the operating fluid's temperature. The maximum operating fluid temperature for achieving temperature class T4 is 60°C. Insulation of the compressor is not recommended unless the manufacturer determines the temperature class accordingly.
Operation and Maintenance
Static electricity can cause explosions, leading to severe injuries. High-power mechanisms should not be used near the product. Regular monitoring of the air amplifier's function and adherence to specified thresholds is crucial.
Summary of Ignition Hazards
Various ignition hazards are identified, including hot surfaces, mechanically generated sparks, flames, hot gases, static electricity, and chemical reactions. Protective measures include defining temperature classes and ensuring proper maintenance.
Appendix
The appendix includes the EU Declaration of Conformity and Declaration of Incorporation for air amplifiers, outlining compliance with safety standards and maintenance requirements.
See more

Catalog excerpts

Installation and operating manual Air Amplifier - MPLV2, SPLV2, GPLV2-1

Maximum Pressure. Installation and operating manual

 Open the catalog to page 1
Installation and operating manual Air Amplifier - MPLV2, SPLV2, GPLV2-2

Key information! Follow the manual for safe and proper use. Keep the manual near the machine for later reference. MAXIMATOR GmbH Lange Straße 6 99734 Nordhausen Germany Phone: +49 3631 9533-0 e-mail: [email protected] Internet: www.maximator.de Warranty and liability: As a general rule, the “General Terms and Conditions” of Maximator GmbH shall apply. These terms and conditions are available at http://www.maximator.de. Warranty and liability claims shall not be accepted if they can be attributed to one or more of the causes mentioned in this manual or explicitly stipulated below: – – – – – –...

 Open the catalog to page 2
Installation and operating manual Air Amplifier - MPLV2, SPLV2, GPLV2-3

General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Information regarding this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Order code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rating plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . List of abbreviations and formula signs used . . . . . . . . ....

 Open the catalog to page 3
Installation and operating manual Air Amplifier - MPLV2, SPLV2, GPLV2-4

Prerequisites for installation . . . . . . . . . . Air amplifier installation . . . . . . . . . . . . . Installation of connecting lines. . . . . . . . . Connecting the drive air . . . . . . . . . . . . . Control air connection . . . . . . . . . . . . . . . Connecting the inlet line and outlet line . . Exhaust silencer installation . . . . . . . . . . . Commissioning . . . . . . . . . . . . . . . . . . . . Prerequisites for commissioning . . . . . . . Commissioning . . . . . . . . . . . . . . . . . . . . Prerequisites for operation . . . . . . . . . . . . . . . . . . . . Normal, safe operation...

 Open the catalog to page 4
Installation and operating manual Air Amplifier - MPLV2, SPLV2, GPLV2-5

Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Summary of ignition hazards . . . . . . . . . ....

 Open the catalog to page 5
Installation and operating manual Air Amplifier - MPLV2, SPLV2, GPLV2-6

General information Information regarding this manual The pneumatically driven air amplifier from MAXIMATOR is a self-reversing, oscillating pressure intensifier and is used to deliver and compress air and nitrogen without the use of oil. The drive fluid and compressed fluid are fed from the same supply line and are therefore identical in terms of pressure and fluid. These instructions apply to air amplifier models MPLV2/SPLV2/GPLV2 (in the sections below referred to as "compressor") and with a serial number of above 23000001. The provided general drawing is an integral part of these instructions...

 Open the catalog to page 6
Installation and operating manual Air Amplifier - MPLV2, SPLV2, GPLV2-7

Rating plate The rating plate is located on the pneumatic cylinder of the compressor and contains the following information:1: 1 Max. permitted operating pressure 2 Air amplifier 3 Type (specifications from the order code) 4 Maximum drive pressure 5 Minimum inlet pressure 6 Calendar week/year of manufac ture 7 Article number 8 Serial number 9 Gear ratio 10 Manufacturer contact information 11 Label according to applied guidelines 12 Operating temperature range 1 Individual compressors may have different rating plates, e.g. metal ones

 Open the catalog to page 7
Installation and operating manual Air Amplifier - MPLV2, SPLV2, GPLV2-8

Explanation of symbols DANGER This combination of symbol and signal word indicates a hazardous situation which - if not avoided - may lead to severe injuries or death. WARNING This combination of symbol and signal word indicates a potentially hazardous situation which - if not avoided - may lead to severe injuries or death. CAUTION This combination of symbol and signal word indicates a potentially hazardous situation which - if not avoided - may lead to light or minor injuries. NOTICE This combination of symbol and signal word indicates a potentially hazardous situation which - if not avoided...

 Open the catalog to page 8
Installation and operating manual Air Amplifier - MPLV2, SPLV2, GPLV2-9

List of abbreviations and formula signs used Abbreviation Tab. 1-2 Formula symbol Qualification of the personnel Only qualified personnel who are specialised and have been trained to do so must work on the air amplifier. Allowing unqualified personnel to work on the compressor or enter the danger zone creates hazards which could lead to death, severe injuries and significant property damage.

 Open the catalog to page 9
Installation and operating manual Air Amplifier - MPLV2, SPLV2, GPLV2-10

Safety and protection measures The following sections stipulate the residual risks associated with the product, even when used as intended. In order to reduce the risk of personal injuries and material damage, and to prevent hazardous situations, you must observe the safety information listed in this section and the warnings in all other sections of this manual. Personal protective equipment Personal protective equipment (in other sections also referred to as PPE) protects personnel from occupational safety and health hazards while at work. Wearing personal protective equipment may be required...

 Open the catalog to page 10
Installation and operating manual Air Amplifier - MPLV2, SPLV2, GPLV2-11

During assessment, check the following leak points: Tab. 2-2 leak point danger zone The hazards are primarily due to the high pressure and extreme temperatures of the operating fluid and/or the hazardous substances used. The system designer must determine detailed danger zones as part of his job and can use his special knowledge of high-pressure technology and the hazardous substances used in each case. Non obvious hazards Using asphyxiant operating fluids can lead to severe injuries or death by asphyxiation. Assess the risk for the equipment in the risk assessment. The following are some potential...

 Open the catalog to page 11
Installation and operating manual Air Amplifier - MPLV2, SPLV2, GPLV2-12

Residual risks Start-up and shut down There is no command device for safe shut-down (E-stop). This can lead to severe injuries or death. Assess the risk for the equipment in the risk assessment. Unexpected restart When restoring the pneumatic energy supply or in case of changes made to the operating parameters, the compressor may start accidentally. This can lead to severe injuries or death. Assess the risk for the equipment in the risk assessment. Risk of injury posed by noise The noise level emitted in the work area depends on the mounting and application. Assess the risk for the equipment...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.