Catalog excerpts
POSITIONERS Technical Brochure Series PNY - PET - PES
Open the catalog to page 1PNEUMATIC POSITIONERS DESCRIPTION The pneumatic positioner PNY01 is a double acting & spring return unit with 3-15 PSI input signal for proportional control of rotary actuators. The positioner operates on the force-balance principle by comparing standard pneumatic signal control with the angular rotation of the stem. PNY01 FEATURES • Same unit for double acting and spring return actuators • Easy conversion from between Fail Open & Fail Closed • Easy and precise calibration w/ SPAN & ZERO adjustments • Possibility to prevent hunting w/ orifice to the small size actuators • 1/2 split range...
Open the catalog to page 2POSIZIONATORI PNEUMATICI ELECTRO PNEUMATIC POSITIONERS PNEUMATIC POSITIONERS DESCRIPTION PET series positioners are double acting & spring return units with 4-20 mA input signal for proportional control of rotary and linear actuators. The positioner operates on the force-balance principle by comparing standard control signal transmitted with the angular rotation of the stem. FEATURES • Same unit for double acting & spring return actuators • Easy conversion from Fail Open & Fail Closed • Easy & precise calibration w/ SPAN & ZERO adjustments • Fast response time & excellent stability •...
Open the catalog to page 3POSITION TRANSMITTER AVAILABLE OPTIONS: Input type Input signal Output signal Load resistance ELECTRO PNEUMATIC POSITIONERS • Internal Mechanical switches (not for linear type) • Internal Position transmitter Noise range Hysteresis Sensivity Supply voltage • High and Low temp • Universal NAMUR VDI/VDE3845 Mounting Bracket Included (30x80mm, 20/30/50mm Height) AREA CLASSIFICATION RATINGS: Type Certificate Protection Rating PET Weatherproof Non-hazardous locations 221.8 MECHANICAL SWITCHES (only available for rotary type) Call ATEX, IECEx Switch Type Input signal IMPORTANT SUGGESTION Use of...
Open the catalog to page 4POSIZIONATORI PNEUMATICI SMART POSITIONERS PNEUMATIC POSITIONERS DESCRIPTION PES Series Smart Valve Positioner controls valve stroke accurately according to input signal of 4-20mA being input from controller. In addition, the integrated microprocessor performs various and powerful functions like Auto calibration, Alarm and Hart protocol. PES features • LCD attached outside the product allows to inspect the state of positioner in the field. • Valve system can be stabilized by outputting analog feedback signal. • Various valve characteristics such as linear, quick open, equal percentage are...
Open the catalog to page 5SMART POSITIONERS AREA CLASSIFICATION RATINGS: Type Certificate ITEM Input signal Protection Rating Supply pressure Weatherproof Non-hazardous locations ATEX, IECEx Air connection Gauge connection Conduit Ambient temperature AVAILABLE OPTIONS: • Internal Mechanical or Proximity switches • Internal Position transmitter • Low temp • HART protocol • ATEX & IECEx Exia Air consumption Required air quality Flow capacity IMPORTANT SUGGESTION Use of filter regulator strongly recommended for long life performance!
Open the catalog to page 6POSIZIONATORI PNEUMATICI EXPLOSION PROOF SMART POSITIONERS PNEUMATIC POSITIONERS PES90 -TECHNICAL DATA ITEM AREA CLASSIFICATION RATINGS: Type Certificate Input Signal Protection Rating Supply pressure ATEX, IECEx Gauge connection Ambient temperature AVAILABLE OPTIONS: • HART protocol • Low temp • PST function • ATEX & IECEx Ex db • EAC & NEPSI Required air quality Flow capacity Protection degree AREA CLASSIFICATION RATINGS: • Zone1&2 Groups E, F, G
Open the catalog to page 7PNY/PET SERIES POSITIONER SERIES PNY = Pneumatic, ordinary location, NAMUR Rotary Motion, For safe area/non-hazardous locations Conduit Connections = 1/2”NPT Air = 1/4” NPT ORDERING CODE PET = Electropneumatic, ordinary locations, NAMUR Rotary Motion, For safe area/non-hazardous locations Conduit Connections = 1/2”NPT Air = 1/4” NPT TEMPERATURE (Blank) = Standard -4°F to 158°F (-20°C to 70°C) HT = High Temperture -4°F to 248°F (-20°C to 120°C) (PET Only) LT = Low Temperature -40°F to 158°F (-40°C to 70°C) (PET Only) SPECIAL OPTIONS COMMUNICATION 01 = None 02 = Position transmitter (4~20mA)...
Open the catalog to page 8ORDERING CODE POSITIONER TYPE PES80 = Smart positioners PES90 = Explosion proof smart positioners MOTION TYPE R = Rotary L = Linear EXPLOSION PROOF TYPE N = For safe area/non-hazardous locations (PES80 only) A = ATEX, IECEx - Intrinsically Safe (PES80 only) C = ATEX, IECEx - Explosion Proof (PES90 only) CONNECTION 1 = Conduit = 1/2”GAS Air = 1/4” NPT 2 = Conduit = 1/2”GAS Air = 1/4” NPT 3 = Conduit = M20x1,5 Air = 1/4” NPT 4 = Conduit = 1/2”NPT Air = 1/4” NPT LEVER 5 = 10-80mm 6 = 70-150mm 7 = Adapter (70mm) A = M6X34L N = NAMUR TEMPERATURE S = Standard PES80 -22°F to 185°F (-30°C to 85°C)...
Open the catalog to page 9All Max-Air Technology catalogs and technical brochures
-
AG Series Technical Brochure
48 Pages
-
Engineered Polymer Actuators
16 Pages
-
Special Rotations 0° to 180°
24 Pages