Group: Matsushita Electric Works
Catalog excerpts
Area Ionizer Wide Area Charge Removal
Open the catalog to page 1Three charge removal modes for diverse application coverage The ER-X series offers an airless charge removal capability to eliminate the need for compressed air in addition to low pressure and high speed compressed air based modes. Furthermore, it supports dual-head configurations for expanded application coverage. ▪Head 1 ▪Head 2 Airless or LowPressure Fast Charge Removal Massive ion discharge when using air reduces charge removal time. By applying a compressed air source, the ion volume increases providing an improved tact time for substrate ionization. This makes the ER-X suitable for...
Open the catalog to page 2Dual Head Configuration for Enhanced Charge Area and Layout Expansion Compressed air is supplied through a port opposite that of the power cable. This allows for the use of a single air line (using a T-branch) to supply multiple ionizers, while a single controller powers and manages two heads. The ER-X series allows for a combination of varied heads sizes for enhanced charge removal area and layout expansion. ▪Controller * he two head units can be set to the same discharge T frequency for synchronization or alternating frequencies between the two heads. LowPressure (Air pressure: Less than...
Open the catalog to page 3Head variations The ER-X series offers four head sizes so you can choose one that best fits your work piece. Compact heads with a 360-degree angle adjustment mechanism The ER-X series heads are compact in size (30 × 22 mm 1.181 × 0.866 in) and installable even in a narrow space. The heads can be rotated 360 degrees to enable charge removal area adjustment after installation. Approx. 160 mm 6.299 in Approx. 320 mm 12.598 in Angle adjustment screw 30 mm (1.181 in) 360degree angle adjustment Approx. 480 mm 18.898 in Approx. 640 mm 25.197 in Effective charge removal width Flat discharge...
Open the catalog to page 4Pulse AC method for faster charge removal* The ER-X series has adopted the pulse AC method that alternately applies positive and negative voltages to each discharge needle. This enables generation and discharge of a large amount of ions, resulting in faster charge removal. In addition, the method offers variable discharge frequency/ion balance (between the positive (+) and negative (-) widths) and is useful for charge removal on different types of workpieces. * Compared with conventional Panasonic models High-speed charge removal on FPCs Example of variable discharge frequency/ ion balance...
Open the catalog to page 5ER-X ORDER GUIDE Heads Head connection cable is not supplied with the head. Please order it separately. Ion balance (±1,000 V→±100 V) Bar type ±30 V or less (Note 1, 2) 1 sec. approx. (Note 1) Model No. ER-X016 320 mm 12.598 in approx. ER-X032 480 mm 18.898 in approx. ER-X048 640mm 25.197 in approx. Charge removal time Appearance Effective charge removal width 160 mm 6.299 in approx. Type ER-X064 Notes: 1) In condition of discharge distance 100 mm 3.937 in, center of the product, discharge wavelength 50 Hz and no air supply. 2) on balance is average of plus and minus. Also, the...
Open the catalog to page 6ER-X SPECIFICATIONS Heads Type Item Model No. Effective charge removal width Head ER-X016 ER-X032 160 mm 6.299 in approx. ER-X048 ER-X064 320 mm 12.598 in approx. 480 mm 18.898 in approx. 640 mm 25.197 in approx. Charge removal time 1 second or less (Note 1) Ion balance ±30 V or less (Note 1, 2) Discharge method Pulse AC method Discharge output voltage 7,000 V approx. Ozone generation 0.01 ppm or less Maximum air pressure 0.5 MPa Applicable fluid Air (dried clean air) (Note 3) Ambient temperature 0 to +50 °C +32 to +122 °F (No dew condensation), Storage: -10 to +65 °C +14 to +149 °F Ambient...
Open the catalog to page 7ER-X I/O CIRCUIT AND WIRING DIAGRAMS When connecting the output to negative common 6 7 COM (+) (Orange) Alarm output Main circuit 9 Housing: 5569-10A [Manufactured by Molex Inc.] Terminal No. 1 2 3 4 5 6 7 8 9 10 Terminal name 10 3 + ─ (Black) Error output Load (Pink) Discharge control input 24 V DC ±10 % 9 10 (Blue) 0 V 1 5 Internal circuit (Green/Yellow) F.G. (Pink) Discharge control input (Orange) Alarm output (Black) Error output (Violet) COM (OUT) + 24 V DC ─ *2 Load ±10 % Load (Blue) 0V 2 COM (─) 2 COM (─) Color code Note: Wire colors are colors of power supply cable of option. 3 4 1...
Open the catalog to page 10ER-X PRECAUTIONS FOR PROPER USE PIPING Controller installation • Air supplied to this product will reduce contamination of the discharge needle and improve the charge removal speed. • The outer diameter of the air tube to fit to the air inlet portion of this product should be ø6 mm ø0.236 in. • Make sure that clean air (air containing no water, no oil and no dust) should be supplied. • Since the pressure will drop when the air piping from the main pressure supply is extended or pneumatic components (e.g., needle valve, speed controller, mini filter) are added, keep an eye on the pressure...
Open the catalog to page 11All Matsushita Electric Works catalogs and technical brochures
-
CA RELAYS
8 Pages
-
AQ-J RELAYS
19 Pages
-
AQ-H RELAYS
14 Pages
-
AQ-G RELAYS
14 Pages
-
AQ-A RELAYS (DC output type)
15 Pages
-
AQ-A RELAYS (AC output type)
17 Pages
-
AQ8 RELAYS
17 Pages
-
AQ1 RELAYS
16 Pages
-
HG-S series
18 Pages
-
HE
6 Pages
-
SFD-WL3
2 Pages
-
SF4D
42 Pages
-
ELC500
8 Pages
-
AC Fan Motor 80×38t
1 Pages
-
GT707
2 Pages
-
GT SERIES
24 Pages
-
GT32-R
2 Pages
-
Shin-G Series
293 Pages
-
MINAS-BL KV Series
52 Pages
-
LP-GS series
12 Pages
-
LP- V SERIES, LP- W SERIES
16 Pages
-
LP-M
12 Pages
-
ER-VW
8 Pages
-
ER-TF SERIES
6 Pages
-
ER-X001
4 Pages
-
EWA2
8 Pages
-
RJ RELAYS (ARJ)
5 Pages
-
SF Relays
4 Pages
-
mechDE Relays (ADE)
4 Pages
-
EX-L200
12 Pages
-
gtseries_e_cata
24 Pages
-
ce_up50_1
6 Pages
-
digest_e_cata
32 Pages
-
fx-100
20 Pages
-
uj30
12 Pages
-
Power relay selector chart
8 Pages
-
NEW & KEY PRODUCTS 2012
32 Pages
-
Aicure UJ30/35 Catalog
12 Pages
-
KW2G-H
4 Pages
-
LP-S series
12 Pages
-
LP-S500W
12 Pages
-
SC-GU3
8 Pages
-
SL-PK01
2 Pages
-
DPC-L100/DPH-L100
12 Pages
-
FP-X0
8 Pages
-
FPOR
20 Pages
-
PM 2
6 Pages
-
PM-24
6 Pages
-
LP-Z Series
4 Pages
-
LP-V/W Series
16 Pages
-
FP2SH
24 Pages
-
LP-300 Series
12 Pages
-
SF4B Ver.2
48 Pages
-
SL-VGU1-485
2 Pages
-
PM-44/PM-54
10 Pages
-
PV200
22 Pages
-
FX-500
20 Pages
-
Flat Type Fiber
2 Pages
-
LP-400 Series
16 Pages
-
MIPTEC catalog
8 Pages
-
PM-64
8 Pages
Archived catalogs
-
Lighting Control Catalog
42 Pages
-
Time Switches
2 Pages
-
Time & Synchronization VIC100
1 Pages
-
GPS Products Antennas
2 Pages
-
Phototriac Coupler
4 Pages
-
Signal Relays
31 Pages