cad

FPOR
20Pages

{{requestButtons}}

Catalog excerpts

FPOR - 1

Programmable Controller FP0R SERIES Conforming to EMC Directive Recognition (Some models only) Listing (Some models only) The New Standard of Ultra-compact PLCs NEW Equipped with RS485 Port Largest in its class *1 Large Capacity Program and Data Memory Fastest in its class *1 Ultra-high Speed Processing Multi-axis Control available without Expansion Industry’s First *2 Battery-less Automatic Backup of All Data *1. Among compact PLCs with up to 128 I/O points based on our research as of July 1, 2011 *2. Based on our research as of July 1, 2011 2011.08 panasonic-electric-works.net/sunx

Open the catalog to page 1
FPOR - 2

Our Mission is to Maximize Customer Benefits with Enhancing Advanced Functionality and Performance. The Answer is , Superior to Basic Ultra- Smallest in its class *1 The control unit is small at 90 mm 3.54 in in height and 25 mm 0.98 in in width. Even when expanded with three expansion units, the total width only 100 mm The ultra-compact space-saving body size facilitates the miniaturization of target machines, equipment, and control panels. Ultra 100 mm 3.94 in I/O points compact Min. 10 points Max. 128 points The number of I/O points is expandable up to 128 by adding three expansion units...

Open the catalog to page 2
FPOR - 3

Outstanding Products Worldwide simultaneous launch of the 3-year warranty For details, visit the following website: panasonic-denko.co.jp/ac/e/fasys/warranty compact Models. 3.94 in. Industry’s First * Battery-less automatic backup of all data The F type (FP0R-F32) has a built-in FeRAM, which is a cutting-edge device that allows the automatic saving of all data without a backup battery. ● There is no need to worry about data loss after a long vacation. ● Battery replacement is no longer necessary when shipping or transferring the unit overseas. ● Replacement of equipment and restoration of...

Open the catalog to page 3
FPOR - 4

POSITIONING ■ Jog positioning control (F171 instruction) The motion can be started without a preset target value. When a stop signal is input, the target value is set, and the motion is slowed to a stop. The jog operation (without a preset target value) The positioning operation is continued until the stop signal is input. slows to a stop. ■ Individual settings for acceleration and deceleration (available for F171, F172, and F174 instructions) The acceleration time and deceleration time can be individually set. Acceleration time Deceleration time The speed can be changed during the jog...

Open the catalog to page 4
FPOR - 5

NETWORK ■ PLC link (MEWNET-W0) ■ FP Web-Server2 Contact data can be shared among up to 16 PLC units, including FP0R, FPΣ, FP-X, FP2/FP2SH, and a mixture of them, without the need for programs. The FP0R operation status can be monitored on a Web browser. RS232C / 2 stations / 115.2 kbps / 15 m 49.2 ft RS232C 1-to-1 link available Connectable with FPΣ, FP-X, FP2/FP2SH as well as FP0R The FP0R operation status can be monitored on a Web browser by connecting FP Web-Server2 and FP0R via RS232C and making required settings using dedicated software (FP Web Configurator Tool 2). FP Web-Server 2...

Open the catalog to page 5
FPOR - 6

OTHER USEFUL FUNCTIONS ■ Program protection ■ Analog I/O ● Program upload protection setting The lineup includes a compact analog I/O unit with one analog output and two analog input channels, an A/D converter unit with eight analog input channels, and a D/A converter unit with four analog output channels. Communication using up to 24 channels is possible. Both the compact body size and the high input/output resolution of 1/4,000 (12 bits) have been achieved. The DIP switches in the unit cover a variety of input/output ranges and are user-friendly. User programs can be protected from...

Open the catalog to page 6
FPOR - 7

PROGRAMMING SOFTWARE ■ Control FPWIN Pro (IEC61131-3 compliant Windows version software) Compliant with international standard IEC61131-3 Programming software approved by PLC Open LD SFC Ladder Diagram Features Sequential Function Chart 1. Five programming languages can be used. IL 2. Easy to reuse well-proven programs FBD Function Block Diagram Instruction List ST Programming can be done using the language most familiar to the developer or using the language most suited to the process to be performed. High-level (structured text) languages that allow structuring, such as C, are supported....

Open the catalog to page 7
FPOR - 8

PART NUMBER LIST ■ Control units 10 points Input: 6, Relay output: 4 10 points Input: 6, Relay output: 4 Terminal block type 14 points Input: 8, Relay output: 6 Connector type 14 points Input: 8, Relay output: 6 Connector type Terminal block type AFP0RC10RS AFP0RC10RM AFP0RC14RS AFP0RC14RM with RS232C AFP0RC10CRS with RS232C AFP0RC10CRM with RS232C AFP0RC14CRS with RS232C AFP0RC14CRM with RS485 AFP0RC10MRS with RS485 AFP0RC14MRS 16 points Input: 8, Transistor output: 8 32 points Input: 16, Transistor output: 16 32 points Input: 16, Transistor output: 16 MIL connector type MIL connector type...

Open the catalog to page 8
FPOR - 9

INSTALLATION AND OPTIONS ■ Installation The control unit width is only 25 mm 0.98 in*. Even when expanded to allow for 128 I/O points, the total width is only 105 mm 4.13 in. The control unit is pocket-sized: W 25 x H 90 x D 60 mm W 0.98 x H 3.54 x D 2.36 in. The number of I/O points can be expanded up to 128. Even with the maximum expansion, the size is only W 105 x H 90 x D 60 mm W 4.13 x H 3.54 x D 2.36 in. The ultra-compact body size and installation area facilitate the miniaturization of target machines, equipment, and control panels. Up to three expansion units can be directly...

Open the catalog to page 9
FPOR - 10

OPTIONS ■ OPTIONS ● RT-3 unit relays (Power PhotoMOS relay type) RT-3 unit relay Contact arrangement 1 Form A × 4 Type DC only (equipped with AQZ102) AC / DC dual use (equipped with AQZ204) Rated input voltage 12 V DC 24 V DC 12 V DC 24 V DC Product No. RT3SP1-12V RT3SP1-24V RT3SP2-12V RT3SP2-24V RT-3 Unit relay Part No. Packing quantity AY34001 AY34002 Inner carton: 1 piece Outer case: 20 pieces AY35001 AY35002 Notes: 1) Only for use with Power PhotoMOS relays. Cannot be equipped with PA relays. 2) Please consult us other contact arrangement. ● RT-3 unit relays (PA relay type) RT-3 unit...

Open the catalog to page 10
FPOR - 11

■ OPTIONS ● Cables Connecting cables for FP series and Interface terminal Interface terminal Product name and shape RT-2 relay terminal RT-1 PC relay terminal − − AY15013 AY15014 AY15015 AY15016 AY15017 − − AY15913 AY15914 AY15915 AY15916 AY15917 − − AY15023 AY15024 AY15025 AY15026 AY15027 − 20-pin Input side: 10-pin × 2 For FP0 and FP0R 8-point input Connecting cable Length (Part number) 500 mm 1,000 mm 1,500 mm 2,000 mm 3,000 mm 5,000 mm 19.69 in 39.37 in 59.06 in 78.74 in 118.11 in 196.85 in − AY15923 AY15924 AY15925 AY15926 AY15927 For FP0, FP0R and FPΣ 16-point input 10-pin RT-2 relay...

Open the catalog to page 11

All Matsushita Electric Works catalogs and technical brochures

  1. CA RELAYS

    8 Pages

  2. AQ-J RELAYS

    19 Pages

  3. AQ-H RELAYS

    14 Pages

  4. AQ-G RELAYS

    14 Pages

  5. AQ8 RELAYS

    17 Pages

  6. AQ1 RELAYS

    16 Pages

  7. HG-S series

    18 Pages

  8. HE

    6 Pages

  9. SFD-WL3

    2 Pages

  10. SF4D

    42 Pages

  11. ELC500

    8 Pages

  12. GT707

    2 Pages

  13. GT SERIES

    24 Pages

  14. GT32-R

    2 Pages

  15. Shin-G Series

    293 Pages

  16. LP-GS series

    12 Pages

  17. LP-M

    12 Pages

  18. ER-VW

    8 Pages

  19. ER-TF SERIES

    6 Pages

  20. ER-X001

    4 Pages

  21. EWA2

    8 Pages

  22. SF Relays

    4 Pages

  23. EX-L200

    12 Pages

  24. ce_up50_1

    6 Pages

  25. digest_e_cata

    32 Pages

  26. fx-100

    20 Pages

  27. uj30

    12 Pages

  28. KW2G-H

    4 Pages

  29. LP-S series

    12 Pages

  30. LP-S500W

    12 Pages

  31. SC-GU3

    8 Pages

  32. SL-PK01

    2 Pages

  33. FP-X0

    8 Pages

  34. PM 2

    6 Pages

  35. PM-24

    6 Pages

  36. LP-Z Series

    4 Pages

  37. LP-V/W Series

    16 Pages

  38. FP2SH

    24 Pages

  39. LP-300 Series

    12 Pages

  40. SF4B Ver.2

    48 Pages

  41. SL-VGU1-485

    2 Pages

  42. PM-44/PM-54

    10 Pages

  43. PV200

    22 Pages

  44. FX-500

    20 Pages

  45. LP-400 Series

    16 Pages

  46. PM-64

    8 Pages

Archived catalogs

  1. Signal Relays

    31 Pages