cad

ER-X001
4Pages

{{requestButtons}}

Catalog excerpts

ER-X001 - 1

CHARGE REMOVAL CHARACTERISTICS (TYPICAL) Please contact our office for details on data that is not listed here. Measured using a 150 × 150 mm 5.906 × 5.906 in CPM (charge plate monitor). (At center of CPM) Charge removal time (sec.) Correlation between charge removal distance and charge removal time (50 Hz) Charge removal distance L (mm in) Spot Type Head ER-X001 Correlation between charge removal distance and charge removal time (20 Hz) Charge removal time (sec.) Charge removal distance L (mm in) Charge removal distance L (mm in) Charge removal distance L (mm in) Charge removal distance L (mm in) Charge removal distance L (mm in) *Based on research conducted by our company as of October 2014. DSC CHECK ERROR HEAD The front panel design is changed. CHECK ERROR HEAD Charge removal distance L (mm in) 8 0.315 Discharge needle unit Head mounting bracket (removable) Clean air outlet (4 points) 18 0.709 Discharge needle unit Panasonic Industrial Devices SUNX Co., Ltd. Global Sales Department 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan 0.3 sec. or less* fastest charge removal achieved with pulse AC method spot type ionizer. Air supply port angle can be adjusted. The pulse AC method enables the ER-X001 to generate and discharge a large amount of ions, which makes charge removal faster. Furthermore, as a spot type ionizer, it achieves the fastest charge removal of 0.3 sec. or less* (±1,000 V → ±100 V). *Based on research conducted by our company as of October 2014. Points of discharge needle ion air outlet Mountable range 24 0.945 of head mounting bracket 6 0.236 ø6.9 ø0.272 high-voltage cable 500 mm 19.685 in long Fastest charge removal* in the industry with ER-X area ionizer with spot type head When using the ER-X001 and ER-X008, use the new controller ER-XC02. The new controller ER-XC02 is compatible with existing heads of the ER-X series. The new controller can be distinguished as follows: Charge removal distance L (mm in) Read the "instruction manual" carefully and thoroughly for the correct and optimum use of this product. (20.5) (0.807) Joint for ø6 ø0.236 air tube (360° rotatable) The CAD data can be downloaded from our website. For more information about controllers, refer to the ER-X series catalog or our website. ø10.5 ø0.413 high-voltage cable 1.2 m 3.937 ft long (internal air tube) Charge removal field (horizontal direction, 0.005 MPa, 10 Hz) Charge removal width W (mm in) Charge removal width W (mm in) Charge removal width W (mm in) Charge removal field (0.5 MPa, 20 Hz) Charge removal field (0.5 MPa, 50 Hz) Charge removal distance L (mm in) Pulse AC method Ultra-compact bar type head Charge removal field (0.005 MPa, 20 Hz) Charge removal width W (mm in) Charge removal field (0.005 MPa, 50 Hz) Charge removal width W (mm in) Charge removal field (airless, 20 Hz) Charge removal width W (mm in) Charge removal width W (mm in) Charge removal field (airless, 50 Hz) Supports airless and low-pressure charge removal, which means charge removal is possible without blowing away tiny work pieces. Free head placement is possible thanks to flexible cable with internal air tube. All Rights Reserved © Panasonic Industrial Devices SUNX Co., Ltd. 2014 Joint for ø6 mm ø0.236 in air tube 360° angle adjustment Simultaneous spot and area charge removal is possible. The new ER-XC02 controller allows simultaneous connection to spot type and bar type heads. Effective charge removal width 50 mm 1.969 in approx. 80 mm 3.150 in approx. 160 mm 6.299 in approx. 320 mm 12.598 in approx. 480 mm 18.898 in approx. 640 mm 25.197 in approx.

Open the catalog to page 1
ER-X001 - 2

Applications of ER-X series compact heads Here are some examples of how the ER-X001 (spot type head) and ER-X008 (ultra-compact bar type head) can be used. ORDER GUIDE Designation The fastest in the industry*, the spot type achieves airless operation for tiny work pieces with high-speed charge removal. Head connection cable Description Spot type Effective charge removal width: 50 mm 1.969 in approx. Ultra-compact bar type Effective charge removal width: 80 mm 3.150 in approx. Number of heads connected: Max. 2 units PhotoMOS relay output Length: 2 m 6.562 ft Cabtyre cable with Length: 5 m...

Open the catalog to page 2
ER-X001 - 3

Applications of ER-X series compact heads Here are some examples of how the ER-X001 (spot type head) and ER-X008 (ultra-compact bar type head) can be used. ORDER GUIDE Designation The fastest in the industry*, the spot type achieves airless operation for tiny work pieces with high-speed charge removal. Head connection cable Description Spot type Effective charge removal width: 50 mm 1.969 in approx. Ultra-compact bar type Effective charge removal width: 80 mm 3.150 in approx. Number of heads connected: Max. 2 units PhotoMOS relay output Length: 2 m 6.562 ft Cabtyre cable with Length: 5 m...

Open the catalog to page 3
ER-X001 - 4

CHARGE REMOVAL CHARACTERISTICS (TYPICAL) Please contact our office for details on data that is not listed here. Measured using a 150 × 150 mm 5.906 × 5.906 in CPM (charge plate monitor). (At center of CPM) Charge removal time (sec.) Correlation between charge removal distance and charge removal time (50 Hz) Charge removal distance L (mm in) Spot Type Head ER-X001 Correlation between charge removal distance and charge removal time (20 Hz) Charge removal time (sec.) Charge removal distance L (mm in) Charge removal distance L (mm in) Charge removal distance L (mm in) Charge removal distance L...

Open the catalog to page 4

All Matsushita Electric Works catalogs and technical brochures

  1. CA RELAYS

    8 Pages

  2. AQ-J RELAYS

    19 Pages

  3. AQ-H RELAYS

    14 Pages

  4. AQ-G RELAYS

    14 Pages

  5. AQ8 RELAYS

    17 Pages

  6. AQ1 RELAYS

    16 Pages

  7. HG-S series

    18 Pages

  8. HE

    6 Pages

  9. SFD-WL3

    2 Pages

  10. SF4D

    42 Pages

  11. ELC500

    8 Pages

  12. GT707

    2 Pages

  13. GT SERIES

    24 Pages

  14. GT32-R

    2 Pages

  15. Shin-G Series

    293 Pages

  16. LP-GS series

    12 Pages

  17. LP-M

    12 Pages

  18. ER-VW

    8 Pages

  19. ER-TF SERIES

    6 Pages

  20. EWA2

    8 Pages

  21. SF Relays

    4 Pages

  22. EX-L200

    12 Pages

  23. ce_up50_1

    6 Pages

  24. digest_e_cata

    32 Pages

  25. fx-100

    20 Pages

  26. uj30

    12 Pages

  27. KW2G-H

    4 Pages

  28. LP-S series

    12 Pages

  29. LP-S500W

    12 Pages

  30. SC-GU3

    8 Pages

  31. SL-PK01

    2 Pages

  32. FP-X0

    8 Pages

  33. FPOR

    20 Pages

  34. PM 2

    6 Pages

  35. PM-24

    6 Pages

  36. LP-Z Series

    4 Pages

  37. LP-V/W Series

    16 Pages

  38. FP2SH

    24 Pages

  39. LP-300 Series

    12 Pages

  40. SF4B Ver.2

    48 Pages

  41. SL-VGU1-485

    2 Pages

  42. PM-44/PM-54

    10 Pages

  43. PV200

    22 Pages

  44. FX-500

    20 Pages

  45. LP-400 Series

    16 Pages

  46. PM-64

    8 Pages

Archived catalogs

  1. Signal Relays

    31 Pages