CHARGE REMOVAL CHARACTERISTICS (TYPICAL) Please contact our office for details on data that is not listed here. Measured using a 150 × 150 mm 5.906 × 5.906 in CPM (charge plate monitor). (At center of CPM) Charge removal time (sec.) Correlation between charge removal distance and charge removal time (50 Hz) Charge removal distance L (mm in) Spot Type Head ER-X001 Correlation between charge removal distance and charge removal time (20 Hz) Charge removal time (sec.) Charge removal distance L (mm in) Charge removal distance L (mm in) Charge removal distance L (mm in) Charge removal distance L (mm in) Charge removal distance L (mm in) *Based on research conducted by our company as of October 2014. DSC CHECK ERROR HEAD The front panel design is changed. CHECK ERROR HEAD Charge removal distance L (mm in) 8 0.315 Discharge needle unit Head mounting bracket (removable) Clean air outlet (4 points) 18 0.709 Discharge needle unit Panasonic Industrial Devices SUNX Co., Ltd. Global Sales Department 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan 0.3 sec. or less* fastest charge removal achieved with pulse AC method spot type ionizer. Air supply port angle can be adjusted. The pulse AC method enables the ER-X001 to generate and discharge a large amount of ions, which makes charge removal faster. Furthermore, as a spot type ionizer, it achieves the fastest charge removal of 0.3 sec. or less* (±1,000 V → ±100 V). *Based on research conducted by our company as of October 2014. Points of discharge needle ion air outlet Mountable range 24 0.945 of head mounting bracket 6 0.236 ø6.9 ø0.272 high-voltage cable 500 mm 19.685 in long Fastest charge removal* in the industry with ER-X area ionizer with spot type head When using the ER-X001 and ER-X008, use the new controller ER-XC02. The new controller ER-XC02 is compatible with existing heads of the ER-X series. The new controller can be distinguished as follows: Charge removal distance L (mm in) Read the "instruction manual" carefully and thoroughly for the correct and optimum use of this product. (20.5) (0.807) Joint for ø6 ø0.236 air tube (360° rotatable) The CAD data can be downloaded from our website. For more information about controllers, refer to the ER-X series catalog or our website. ø10.5 ø0.413 high-voltage cable 1.2 m 3.937 ft long (internal air tube) Charge removal field (horizontal direction, 0.005 MPa, 10 Hz) Charge removal width W (mm in) Charge removal width W (mm in) Charge removal width W (mm in) Charge removal field (0.5 MPa, 20 Hz) Charge removal field (0.5 MPa, 50 Hz) Charge removal distance L (mm in) Pulse AC method Ultra-compact bar type head Charge removal field (0.005 MPa, 20 Hz) Charge removal width W (mm in) Charge removal field (0.005 MPa, 50 Hz) Charge removal width W (mm in) Charge removal field (airless, 20 Hz) Charge removal width W (mm in) Charge removal width W (mm in) Charge removal field (airless, 50 Hz) Supports airless and low-pressure charge removal, which means charge removal is possible without blowing away tiny work pieces. Free head placement is possible thanks to flexible cable with internal air tube. All Rights Reserved © Panasonic Industrial Devices SUNX Co., Ltd. 2014 Joint for ø6 mm ø0.236 in air tube 360° angle adjustment Simultaneous spot and area charge removal is possible. The new ER-XC02 controller allows simultaneous connection to spot type and bar type heads. Effective charge removal width 50 mm 1.969 in approx. 80 mm 3.150 in approx. 160 mm 6.299 in approx. 320 mm 12.598 in approx. 480 mm 18.898 in approx. 640 mm 25.197 in approx.
Open the catalog to page 1Applications of ER-X series compact heads Here are some examples of how the ER-X001 (spot type head) and ER-X008 (ultra-compact bar type head) can be used. ORDER GUIDE Designation The fastest in the industry*, the spot type achieves airless operation for tiny work pieces with high-speed charge removal. Head connection cable Description Spot type Effective charge removal width: 50 mm 1.969 in approx. Ultra-compact bar type Effective charge removal width: 80 mm 3.150 in approx. Number of heads connected: Max. 2 units PhotoMOS relay output Length: 2 m 6.562 ft Cabtyre cable with Length: 5 m...
Open the catalog to page 2Applications of ER-X series compact heads Here are some examples of how the ER-X001 (spot type head) and ER-X008 (ultra-compact bar type head) can be used. ORDER GUIDE Designation The fastest in the industry*, the spot type achieves airless operation for tiny work pieces with high-speed charge removal. Head connection cable Description Spot type Effective charge removal width: 50 mm 1.969 in approx. Ultra-compact bar type Effective charge removal width: 80 mm 3.150 in approx. Number of heads connected: Max. 2 units PhotoMOS relay output Length: 2 m 6.562 ft Cabtyre cable with Length: 5 m...
Open the catalog to page 3CHARGE REMOVAL CHARACTERISTICS (TYPICAL) Please contact our office for details on data that is not listed here. Measured using a 150 × 150 mm 5.906 × 5.906 in CPM (charge plate monitor). (At center of CPM) Charge removal time (sec.) Correlation between charge removal distance and charge removal time (50 Hz) Charge removal distance L (mm in) Spot Type Head ER-X001 Correlation between charge removal distance and charge removal time (20 Hz) Charge removal time (sec.) Charge removal distance L (mm in) Charge removal distance L (mm in) Charge removal distance L (mm in) Charge removal distance L...
Open the catalog to page 4All Matsushita Electric Works catalogs and technical brochures
-
Narrow pitch RF connectors
12 Pages
-
High Current Connectors
12 Pages
-
Ultra-slim Photoelectric Sensor
16 Pages
-
Laser Distance Sensor
16 Pages
-
CA RELAYS
8 Pages
-
AQ-J RELAYS
19 Pages
-
AQ-H RELAYS
14 Pages
-
AQ-G RELAYS
14 Pages
-
AQ-A RELAYS (DC output type)
15 Pages
-
AQ-A RELAYS (AC output type)
17 Pages
-
AQ8 RELAYS
17 Pages
-
AQ1 RELAYS
16 Pages
-
HG-S series
18 Pages
-
HE
6 Pages
-
SFD-WL3
2 Pages
-
SF4D
42 Pages
-
ELC500
8 Pages
-
AC Fan Motor 80×38t
1 Pages
-
GT707
2 Pages
-
GT SERIES
24 Pages
-
GT32-R
2 Pages
-
Shin-G Series
293 Pages
-
MINAS-BL KV Series
52 Pages
-
LP-GS series
12 Pages
-
LP- V SERIES, LP- W SERIES
16 Pages
-
LP-M
12 Pages
-
ER-VW
8 Pages
-
ER-TF SERIES
6 Pages
-
EWA2
8 Pages
-
RJ RELAYS (ARJ)
5 Pages
-
SF Relays
4 Pages
-
mechDE Relays (ADE)
4 Pages
-
EX-L200
12 Pages
-
gtseries_e_cata
24 Pages
-
ce_up50_1
6 Pages
-
digest_e_cata
32 Pages
-
fx-100
20 Pages
-
uj30
12 Pages
-
Power relay selector chart
8 Pages
-
NEW & KEY PRODUCTS 2012
32 Pages
-
Aicure UJ30/35 Catalog
12 Pages
-
KW2G-H
4 Pages
-
LP-S series
12 Pages
-
LP-S500W
12 Pages
-
SC-GU3
8 Pages
-
SL-PK01
2 Pages
-
DPC-L100/DPH-L100
12 Pages
-
FP-X0
8 Pages
-
FPOR
20 Pages
-
PM 2
6 Pages
-
PM-24
6 Pages
-
LP-Z Series
4 Pages
-
LP-V/W Series
16 Pages
-
FP2SH
24 Pages
-
LP-300 Series
12 Pages
-
SF4B Ver.2
48 Pages
-
SL-VGU1-485
2 Pages
-
PM-44/PM-54
10 Pages
-
PV200
22 Pages
-
FX-500
20 Pages
-
Flat Type Fiber
2 Pages
-
LP-400 Series
16 Pages
-
MIPTEC catalog
8 Pages
-
PM-64
8 Pages
Archived catalogs
-
Lighting Control Catalog
42 Pages
-
Time Switches
2 Pages
-
Time & Synchronization VIC100
1 Pages
-
GPS Products Antennas
2 Pages
-
Phototriac Coupler
4 Pages
-
Signal Relays
31 Pages