Head-separated·Dual display For gas & liquid DIGITAL PRESSURE SENSOR Controller DPC-L100 SERIES Sensor head DPH-L100 SERIES Conforming to EMC Directive Powerful and Simple High-precision detection of uid and air pressure 2011.01 panasonic-electric-works.net/sunx Panasonic Electric Works SUNX
Open the catalog to page 1Featuring exceptional resistance to… Interference The DPC-L100 and DPH-L100 comply with EMC directives, ensuring they won’t succumb to external interference. Pressure surges An integrated throttle prevents damage from sudden bursts of high pressure. Vibrations and mechanical shock The DPC-L100 and DPH-L100 are easy to use with devices that are subject to high levels of vibration. Water and dust The DPC-L100 and DPH-L100 feature an IP67compliant protective enclosure. (IEC) Fluid heat The DPC-L100 and DPH-L100 can accommodate media at temperatures of up to 125°C (10 MPa and 50 MPa models)....
Open the catalog to page 2Simple Introducing a controller that’s as simple to operate as it is compact Buttons generate a distinct “click” that can be felt through gloves. Dual display Direct setting Current value Direct setting of threshold value “Current value” and “Threshold value” can be checked at the he same time. The threshold value can be changed in RUN mode directly. y. Threshold value 3-color display (Red, Green, Orange) The main display changes color in line with changes in the status of output ON / OFF operation, and it also changes color while setting is in progress. The sensor status can therefore be...
Open the catalog to page 3Full range of performance and functions in a compact body 1 model to suit a wide variety of applications Inputs Outputs Comparative output 1 Remote zero-adjustment input Auto-reference input Comparative output 2 Selection Current value hold input Analog voltage output 1 to 5 V Selection Analog current output 4 to 20 mA Equipped with independent dual output Equipped with auto-reference / remote zero-adjustment functions Equipped with two independent comparative outputs, and separate sensing modes can be selected for each of them. Since there are two comparative outputs, one of the...
Open the catalog to page 4Copy function reduces man-hours and human error Copy of the setting details for the master sensor can be transmitted as data to the other sensors. If making the same settings for multiple sensors, this prevents setting errors from occurring with the other sensors and also reduces the number of changes required to instruction manuals when equipment designs are changed. Setting details can be understood at a glance The setting details (output, response time and external input, etc.) appear in the digital display. Because the settings are in numeric form that can be easily understood. What are...
Open the catalog to page 5PRODUCT CONFIGURATION Connector (e-CON) Sensor head Power supply connector Controller Connector attached cable ORDER GUIDE Sensor heads Type Appearance Rated pressure range -0.1 to +1.0 MPa DPH-L113V 0 to +1.0 MPa DPH-L113 0 to +3.5 MPa DPH-L133 0 to +10 MPa DPH-L114 0 to +50 MPa Compound pressure Model No. DPH-L154 Positive pressure Controllers Appearance Model No. Comparative output DPC-L101 * CN-66A-C2 (Connector attached cable 2 m 6.562 ft) is attached. NPN open-collector transistor DPC-L101-P PNP open-collector transistor Type without connector attached cable Type without connector...
Open the catalog to page 6OPTIONS Sensor head connector (e-CON) Designation Sensor head connector (e-CON) Connector attached cable Power supply connector Model No. CN-EP2 (Note 1) 5 pcs. per set Description • CN-EP2 Connector for connecting sensor head controller CN-66A-C2 (Note 2) Length 2 m 6.562 ft Controller power supply / I-O cable. CN-66A-C5 CN-66A 5 pcs. per set 0.2 mm² 6-core oil-resistant cabtyre Length 5 m 16.404 ft cable with connector Note: One is attached to each sensor head according to standard. Connector for controller power supply / I-O cable. Connector attached cable • CN-66A-C2 • CN-66A-C5...
Open the catalog to page 7SPECIFICATIONS Sensor heads Type Item Model No. Compound pressure Positive pressure -0.1 to 1 MPa type 1 MPa type 3.5 MPa type 10 MPa type 50 MPa type DPH-L113V DPH-L113 DPH-L133 DPH-L114 DPH-L154 -0.1 to +1 MPa 0 to +1 MPa 0 to +3.5 MPa 0 to +10 MPa 0 to +50 MPa 2 MPa 7 MPa 20 MPa 75 MPa Type of pressure Rated pressure range Pressure withstandability Sealed gauge pressure (Note 4) 2 MPa Applicable uid Gases and uids that do not corrode SUS630, SUS304, or SUSXM7 Supply voltage 9 to 36 V DC [9 to 32 V DC when using the attached connector (e-CON)] Analog voltage output Output voltage: 1 to 5...
Open the catalog to page 8SPECIFICATIONS Item Model No. Controllers NPN output DPC-L101 PNP output Applicable sensor head Rated pressure range DPC-L101-P DPH-L113V DPH-L113 DPH-L133 DPH-L114 DPH-L154 -0.1 to +1 MPa 0 to +1 MPa 0 to +3.5 MPa 0 to +10 MPa 0 to +50 MPa -1.177 to +1.177 MPa -12.00 to +12.00 kgf/cm² -11.77 to +11.77 bar -170.6 to +170.6 psi -1.070 to +1.070 MPa -10.91 to +10.91 kgf/cm² -10.70 to +10.70 bar -155.2 to +155.2 psi -3.74 to +3.74 MPa -38.1 to +38.1 kgf/cm² -37.4 to +37.4 bar -542 to +542 psi -10.70 to +10.70 MPa -109.1 to +109.1 kgf/cm² -107.0 to +107.0 bar -1552 to +1552 psi -53.5 to +53.5...
Open the catalog to page 9I/O CIRCUIT AND WIRING DIAGRAMS DPH-L1□ For independent use of sensor head Terminal No. Color code Sensor head main circuit (Brown) +V (Black) Analog voltage output (1 to 5 V) + 9 to 36 V DC – (Blue) 0 V Sensor head internal circuit User’s circuit Notes: 1) When the sensor head is used independently, devices connected to the analog output must have an input impedance set at 10 kΩ or more and load capacity 1,000 pF or less. 2) No short-circuit protection circuit is provided for analog voltage output. Do not connect directly to a power supply. 3) The pressure port and internal circuitry are...
Open the catalog to page 10PRECAUTIONS FOR PROPER USE Disclaimer • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. • The DPH-L100 series is designed for use with air and non-corrosive gas. It cannot be used with liquid or corrosive and inammable gases. The applications described in the catalog are all intended for examples only. The purchase of our products described in the catalog shall not be...
Open the catalog to page 11All Matsushita Electric Works catalogs and technical brochures
-
Narrow pitch RF connectors
12 Pages
-
High Current Connectors
12 Pages
-
Ultra-slim Photoelectric Sensor
16 Pages
-
Laser Distance Sensor
16 Pages
-
CA RELAYS
8 Pages
-
AQ-J RELAYS
19 Pages
-
AQ-H RELAYS
14 Pages
-
AQ-G RELAYS
14 Pages
-
AQ-A RELAYS (DC output type)
15 Pages
-
AQ-A RELAYS (AC output type)
17 Pages
-
AQ8 RELAYS
17 Pages
-
AQ1 RELAYS
16 Pages
-
HG-S series
18 Pages
-
HE
6 Pages
-
SFD-WL3
2 Pages
-
SF4D
42 Pages
-
ELC500
8 Pages
-
AC Fan Motor 80×38t
1 Pages
-
GT707
2 Pages
-
GT SERIES
24 Pages
-
GT32-R
2 Pages
-
Shin-G Series
293 Pages
-
MINAS-BL KV Series
52 Pages
-
LP-GS series
12 Pages
-
LP- V SERIES, LP- W SERIES
16 Pages
-
LP-M
12 Pages
-
ER-VW
8 Pages
-
ER-TF SERIES
6 Pages
-
ER-X001
4 Pages
-
EWA2
8 Pages
-
RJ RELAYS (ARJ)
5 Pages
-
SF Relays
4 Pages
-
mechDE Relays (ADE)
4 Pages
-
EX-L200
12 Pages
-
gtseries_e_cata
24 Pages
-
ce_up50_1
6 Pages
-
digest_e_cata
32 Pages
-
fx-100
20 Pages
-
uj30
12 Pages
-
Power relay selector chart
8 Pages
-
NEW & KEY PRODUCTS 2012
32 Pages
-
Aicure UJ30/35 Catalog
12 Pages
-
KW2G-H
4 Pages
-
LP-S series
12 Pages
-
LP-S500W
12 Pages
-
SC-GU3
8 Pages
-
SL-PK01
2 Pages
-
FP-X0
8 Pages
-
FPOR
20 Pages
-
PM 2
6 Pages
-
PM-24
6 Pages
-
LP-Z Series
4 Pages
-
LP-V/W Series
16 Pages
-
FP2SH
24 Pages
-
LP-300 Series
12 Pages
-
SF4B Ver.2
48 Pages
-
SL-VGU1-485
2 Pages
-
PM-44/PM-54
10 Pages
-
PV200
22 Pages
-
FX-500
20 Pages
-
Flat Type Fiber
2 Pages
-
LP-400 Series
16 Pages
-
MIPTEC catalog
8 Pages
-
PM-64
8 Pages
Archived catalogs
-
Lighting Control Catalog
42 Pages
-
Time Switches
2 Pages
-
Time & Synchronization VIC100
1 Pages
-
GPS Products Antennas
2 Pages
-
Phototriac Coupler
4 Pages
-
Signal Relays
31 Pages