cad

DPC-L100/DPH-L100
12Pages

{{requestButtons}}

Catalog excerpts

DPC-L100/DPH-L100 - 1

Head-separated·Dual display For gas & liquid DIGITAL PRESSURE SENSOR Controller DPC-L100 SERIES Sensor head DPH-L100 SERIES Conforming to EMC Directive Powerful and Simple High-precision detection of uid and air pressure 2011.01 panasonic-electric-works.net/sunx Panasonic Electric Works SUNX

Open the catalog to page 1
DPC-L100/DPH-L100 - 2

Featuring exceptional resistance to… Interference The DPC-L100 and DPH-L100 comply with EMC directives, ensuring they won’t succumb to external interference. Pressure surges An integrated throttle prevents damage from sudden bursts of high pressure. Vibrations and mechanical shock The DPC-L100 and DPH-L100 are easy to use with devices that are subject to high levels of vibration. Water and dust The DPC-L100 and DPH-L100 feature an IP67compliant protective enclosure. (IEC) Fluid heat The DPC-L100 and DPH-L100 can accommodate media at temperatures of up to 125°C (10 MPa and 50 MPa models)....

Open the catalog to page 2
DPC-L100/DPH-L100 - 3

Simple Introducing a controller that’s as simple to operate as it is compact Buttons generate a distinct “click” that can be felt through gloves. Dual display Direct setting Current value Direct setting of threshold value “Current value” and “Threshold value” can be checked at the he same time. The threshold value can be changed in RUN mode directly. y. Threshold value 3-color display (Red, Green, Orange) The main display changes color in line with changes in the status of output ON / OFF operation, and it also changes color while setting is in progress. The sensor status can therefore be...

Open the catalog to page 3
DPC-L100/DPH-L100 - 4

Full range of performance and functions in a compact body 1 model to suit a wide variety of applications Inputs Outputs Comparative output 1 Remote zero-adjustment input Auto-reference input Comparative output 2 Selection Current value hold input Analog voltage output 1 to 5 V Selection Analog current output 4 to 20 mA Equipped with independent dual output Equipped with auto-reference / remote zero-adjustment functions Equipped with two independent comparative outputs, and separate sensing modes can be selected for each of them. Since there are two comparative outputs, one of the...

Open the catalog to page 4
DPC-L100/DPH-L100 - 5

Copy function reduces man-hours and human error Copy of the setting details for the master sensor can be transmitted as data to the other sensors. If making the same settings for multiple sensors, this prevents setting errors from occurring with the other sensors and also reduces the number of changes required to instruction manuals when equipment designs are changed. Setting details can be understood at a glance The setting details (output, response time and external input, etc.) appear in the digital display. Because the settings are in numeric form that can be easily understood. What are...

Open the catalog to page 5
DPC-L100/DPH-L100 - 6

PRODUCT CONFIGURATION Connector (e-CON) Sensor head Power supply connector Controller Connector attached cable ORDER GUIDE Sensor heads Type Appearance Rated pressure range -0.1 to +1.0 MPa DPH-L113V 0 to +1.0 MPa DPH-L113 0 to +3.5 MPa DPH-L133 0 to +10 MPa DPH-L114 0 to +50 MPa Compound pressure Model No. DPH-L154 Positive pressure Controllers Appearance Model No. Comparative output DPC-L101 * CN-66A-C2 (Connector attached cable 2 m 6.562 ft) is attached. NPN open-collector transistor DPC-L101-P PNP open-collector transistor Type without connector attached cable Type without connector...

Open the catalog to page 6
DPC-L100/DPH-L100 - 7

OPTIONS Sensor head connector (e-CON) Designation Sensor head connector (e-CON) Connector attached cable Power supply connector Model No. CN-EP2 (Note 1) 5 pcs. per set Description • CN-EP2 Connector for connecting sensor head controller CN-66A-C2 (Note 2) Length 2 m 6.562 ft Controller power supply / I-O cable. CN-66A-C5 CN-66A 5 pcs. per set 0.2 mm² 6-core oil-resistant cabtyre Length 5 m 16.404 ft cable with connector Note: One is attached to each sensor head according to standard. Connector for controller power supply / I-O cable. Connector attached cable • CN-66A-C2 • CN-66A-C5...

Open the catalog to page 7
DPC-L100/DPH-L100 - 8

SPECIFICATIONS Sensor heads Type Item Model No. Compound pressure Positive pressure -0.1 to 1 MPa type 1 MPa type 3.5 MPa type 10 MPa type 50 MPa type DPH-L113V DPH-L113 DPH-L133 DPH-L114 DPH-L154 -0.1 to +1 MPa 0 to +1 MPa 0 to +3.5 MPa 0 to +10 MPa 0 to +50 MPa 2 MPa 7 MPa 20 MPa 75 MPa Type of pressure Rated pressure range Pressure withstandability Sealed gauge pressure (Note 4) 2 MPa Applicable uid Gases and uids that do not corrode SUS630, SUS304, or SUSXM7 Supply voltage 9 to 36 V DC [9 to 32 V DC when using the attached connector (e-CON)] Analog voltage output Output voltage: 1 to 5...

Open the catalog to page 8
DPC-L100/DPH-L100 - 9

SPECIFICATIONS Item Model No. Controllers NPN output DPC-L101 PNP output Applicable sensor head Rated pressure range DPC-L101-P DPH-L113V DPH-L113 DPH-L133 DPH-L114 DPH-L154 -0.1 to +1 MPa 0 to +1 MPa 0 to +3.5 MPa 0 to +10 MPa 0 to +50 MPa -1.177 to +1.177 MPa -12.00 to +12.00 kgf/cm² -11.77 to +11.77 bar -170.6 to +170.6 psi -1.070 to +1.070 MPa -10.91 to +10.91 kgf/cm² -10.70 to +10.70 bar -155.2 to +155.2 psi -3.74 to +3.74 MPa -38.1 to +38.1 kgf/cm² -37.4 to +37.4 bar -542 to +542 psi -10.70 to +10.70 MPa -109.1 to +109.1 kgf/cm² -107.0 to +107.0 bar -1552 to +1552 psi -53.5 to +53.5...

Open the catalog to page 9
DPC-L100/DPH-L100 - 10

I/O CIRCUIT AND WIRING DIAGRAMS DPH-L1□ For independent use of sensor head Terminal No. Color code Sensor head main circuit (Brown) +V (Black) Analog voltage output (1 to 5 V) + 9 to 36 V DC – (Blue) 0 V Sensor head internal circuit User’s circuit Notes: 1) When the sensor head is used independently, devices connected to the analog output must have an input impedance set at 10 kΩ or more and load capacity 1,000 pF or less. 2) No short-circuit protection circuit is provided for analog voltage output. Do not connect directly to a power supply. 3) The pressure port and internal circuitry are...

Open the catalog to page 10
DPC-L100/DPH-L100 - 11

PRECAUTIONS FOR PROPER USE Disclaimer • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. • The DPH-L100 series is designed for use with air and non-corrosive gas. It cannot be used with liquid or corrosive and inammable gases. The applications described in the catalog are all intended for examples only. The purchase of our products described in the catalog shall not be...

Open the catalog to page 11

All Matsushita Electric Works catalogs and technical brochures

  1. CA RELAYS

    8 Pages

  2. AQ-J RELAYS

    19 Pages

  3. AQ-H RELAYS

    14 Pages

  4. AQ-G RELAYS

    14 Pages

  5. AQ8 RELAYS

    17 Pages

  6. AQ1 RELAYS

    16 Pages

  7. HG-S series

    18 Pages

  8. HE

    6 Pages

  9. SFD-WL3

    2 Pages

  10. SF4D

    42 Pages

  11. ELC500

    8 Pages

  12. GT707

    2 Pages

  13. GT SERIES

    24 Pages

  14. GT32-R

    2 Pages

  15. Shin-G Series

    293 Pages

  16. LP-GS series

    12 Pages

  17. LP-M

    12 Pages

  18. ER-VW

    8 Pages

  19. ER-TF SERIES

    6 Pages

  20. ER-X001

    4 Pages

  21. EWA2

    8 Pages

  22. SF Relays

    4 Pages

  23. EX-L200

    12 Pages

  24. ce_up50_1

    6 Pages

  25. digest_e_cata

    32 Pages

  26. fx-100

    20 Pages

  27. uj30

    12 Pages

  28. KW2G-H

    4 Pages

  29. LP-S series

    12 Pages

  30. LP-S500W

    12 Pages

  31. SC-GU3

    8 Pages

  32. SL-PK01

    2 Pages

  33. FP-X0

    8 Pages

  34. FPOR

    20 Pages

  35. PM 2

    6 Pages

  36. PM-24

    6 Pages

  37. LP-Z Series

    4 Pages

  38. LP-V/W Series

    16 Pages

  39. FP2SH

    24 Pages

  40. LP-300 Series

    12 Pages

  41. SF4B Ver.2

    48 Pages

  42. SL-VGU1-485

    2 Pages

  43. PM-44/PM-54

    10 Pages

  44. PV200

    22 Pages

  45. FX-500

    20 Pages

  46. LP-400 Series

    16 Pages

  47. PM-64

    8 Pages

Archived catalogs

  1. Signal Relays

    31 Pages