CA RELAYS - 1

Automation Controls Catalog Panasonic Small Size, Light Weight Automotive Power Relays FEATURES • Small size and light weight • Since the terminal arrangement complies with JIS • Low operating power (1.4W) type is available (1 Form A, 1 Form B) TYPICAL APPLICATIONS • Motorcycles and automobiles Motorcycle cell motors, car air conditioners, halogen lamps, etc. • Agricultural equipment • Battery equipped devices such as conveyance vehicles RoHS compliant ORDERING INFORMATION CA Contact arrangement 1a: 1 Form A 1b: 1 Form B 1: 1 Form C Protective construction Nil: Sealed F: Dust cover Rated operating power Nil: Standard type (1.8 W) S: Low operating power type (1.4 W) (1 Form A, 1 Form B) Protective element Nil: None R: With resistor inside Rated coil voltage (DC) DC12V : 1 Form C only DC24V : 1 Form C only 12V : 1 Form A or 1 Form B Mounting method A: Rubber bracket A type (1 Form A, 1 Form B) N: Screw mounting type C: Direct coupling type Classification by type Nil: 1 Form C 5: 1 Form A or 1 Form B

Open the catalog to page 1
CA RELAYS - 2

TYPES Contact arrangement Note: Please use “CA**R-*-*-* or CA**SR-*-*-*” with resistor inside type. (Asterisks “ * ” should be filled in from ORDERING INFORMATION.) RATING 1. Coil data Contact arrangement Note: Other operate (set) voltage types are also available. Please inquire our sales representative for details. Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ — 2 —

Open the catalog to page 2
CA RELAYS - 3

Notes: *1. Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you confirm operation under actual conditions. *2. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. For details, please refer to the “Automotive Relay Users Guide”. Please inquire our sales representative if you will be using the relay in a high temperature atmosphere (110°C 230°F) Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ — 3 — © Panasonic Corporation...

Open the catalog to page 3
CA RELAYS - 4

Notes: *1. Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you confirm operation under actual conditions. *2. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. For details, please refer to the “Automotive Relay Users Guide”. Please inquire our sales representative if you will be using the relay in a high temperature atmosphere (110°C 230°F) Electrical life Contact arrangement Panasonic Corporation Electromechanical Control Business Division...

Open the catalog to page 4
CA RELAYS - 5

REFERENCE DATA 1. Coil temperature rise Samples: CA1aS-12V-N-5, 5pcs. Measured portion: Inside the coil Carrying current: 20A Ambient temperature: Room temperature, 80°C 176°F 2. Ambient temperature and usable voltage range 3. Ambient temperature characteristics (Cold start) Samples: CA1bS-12V-N-5 4. Distribution of operate (set) and release (reset) voltage Quantity: 50pcs. 5. Distribution of operate (set) and release (reset) time Sample: CA1a-12V-N-5, 10pcs. Change of operate (set) and release (reset) Change of contact resistance 6.-(1) Electrical life test (Motor load) Sample: CA1a-12V-C,...

Open the catalog to page 5
CA RELAYS - 6

DIMENSIONS (mm nch) The CAD data of the products with a mark can be downloaded from: http://industrial.panasonic.eom/ac/e/ Note: Including resistor type also available. Including resistor (1 Form A) Dimension: Tolerance External dimensions Schematic (Bottom View) _14.4_ .567 Note: Including resistor type also available. Including resistor (1 Form A) Dimension: Tolerance Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ — 6 —

Open the catalog to page 6
CA RELAYS - 7

Schematic (Bottom View) 3.1 Form A / 1 Form B Direct coupling type External dimensions Dimension: Tolerance 4.1 Form C Screw-mounting type External dimensions Schematic (Bottom View) Including resistor Dimension: Tolerance 5.1 Form C Direct coupling type External dimensions Schematic (Bottom View) Dimension: Tolerance Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ — 7 —

Open the catalog to page 7
CA RELAYS - 8

Panasonic Corporation Electromechanical Control Business Division ■ 1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan industrial.panasonic.com/ac/e/ ■ ® Panasonic ©Panasonic Corporation 2019 ASCTB219E 201908 Specifications are subject to changewithoutnotice.

Open the catalog to page 8

All Matsushita Electric Works catalogs and technical brochures

  1. AQ-J RELAYS

    19 Pages

  2. AQ-H RELAYS

    14 Pages

  3. AQ-G RELAYS

    14 Pages

  4. AQ8 RELAYS

    17 Pages

  5. AQ1 RELAYS

    16 Pages

  6. HG-S series

    18 Pages

  7. HE

    6 Pages

  8. SFD-WL3

    2 Pages

  9. SF4D

    42 Pages

  10. ELC500

    8 Pages

  11. GT707

    2 Pages

  12. GT SERIES

    24 Pages

  13. GT32-R

    2 Pages

  14. Shin-G Series

    293 Pages

  15. LP-GS series

    12 Pages

  16. LP-M

    12 Pages

  17. ER-VW

    8 Pages

  18. ER-TF SERIES

    6 Pages

  19. ER-X001

    4 Pages

  20. EWA2

    8 Pages

  21. SF Relays

    4 Pages

  22. EX-L200

    12 Pages

  23. ce_up50_1

    6 Pages

  24. digest_e_cata

    32 Pages

  25. fx-100

    20 Pages

  26. uj30

    12 Pages

  27. KW2G-H

    4 Pages

  28. LP-S series

    12 Pages

  29. LP-S500W

    12 Pages

  30. SC-GU3

    8 Pages

  31. SL-PK01

    2 Pages

  32. FP-X0

    8 Pages

  33. FPOR

    20 Pages

  34. PM 2

    6 Pages

  35. PM-24

    6 Pages

  36. LP-Z Series

    4 Pages

  37. LP-V/W Series

    16 Pages

  38. FP2SH

    24 Pages

  39. LP-300 Series

    12 Pages

  40. SF4B Ver.2

    48 Pages

  41. SL-VGU1-485

    2 Pages

  42. PM-44/PM-54

    10 Pages

  43. PV200

    22 Pages

  44. FX-500

    20 Pages

  45. LP-400 Series

    16 Pages

  46. PM-64

    8 Pages

Archived catalogs

  1. Signal Relays

    31 Pages