Group: Matsushita Electric Works
Catalog excerpts
Automation Controls Catalog Solid State Relays AQ1 RELAYS High capacity up to 10 A PC board terminal type FEATURES 10 A high capacity realized for PC board terminal (when using heat sink) Vertical types with SIL terminal arrangement and flat types are available. Built-in snubber circuit prevents malfunction due to noise. Safety standards • C-UL (UL508) certified • VDE (EN60950-1) reinforced insulation certified TYPICAL APPLICATIONS Printing machines Terminal equipment of data processing NC machines Packing machines Automatic ticket punchers ORDERING INFORMATION (PART NO.) AQ 1 Type 2: Zero-cross AC output (Vertical type) 3: Zero-cross AC output (Flat type) 6: Random AC output (Vertical type)* 7: Random AC output (Flat type)* Load current/Load voltage Control voltage * Random types are available by custom order. ORDERING INFORMATION (TYPE NO.) Load voltage 2: 75 to 250 Vrms Type ZT: Zero-cross AC output T: Random AC output* Shape Nil: Vertical type J: Flat type * Random types are available by custom order.
Open the catalog to page 1■ AQ1 Solid State Relays
Open the catalog to page 2Solid State Relays AQ1 RELAYS 1-2.Load current vs. ambient temperature characteristics (10A Type) Part No.: AQ1208 1-1.Load current vs. ambient temperature characteristics (3A Type) Part No.: AQ1298 and AQ1398 Allowable ambient temperature: -30 to +80°C Teated condition: When attached to a heat sink, use a heat conductive compound. (Ex. Momentive Performance Materials Inc. YG6111 or TSK5303) of similar coating to improve cooling. 2.Non-repetitive surge current vs. carrying time* (3A and 10A Types) Part No.: AQ1298, AQ1398 and AQ1208 3.Input current vs. input voltage characteristics (3 A and...
Open the catalog to page 3Solid State Relays AQ1 RELAYS DIMENSIONS CAD The CAD data of the products with a “CAD” mark can be downloaded from our Website. Mounting hole location (Copper-side view) 3A Type: Flat External dimensions Mounting hole location (Copper-side view) 4 - 1.2 dia. 10A Type: Vertical External dimensions * There 2 holes are not necessary when not using heat sink (AQ-HS-5A) Mounting hole location (Copper-side view) Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/
Open the catalog to page 4Solid State Relays AQ1 RELAYS Heat sink (for AQ1801) External dimensions Heat sink attached to AQ1 relay 5.2 Note: hen using heat sink, W please refer to “Thermal design” of NOTES. Knurl surface SCHEMATIC AND WIRING DIAGRAMS Output configuration Wiring diagram Vertical type Input circuit Zero-cross circuit Load power Operation supply power Load power supply − Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ Input circuit Operation power
Open the catalog to page 5I Cautions for use AQ1 relays ► When using bent output terminals To avoid applying mechanical stress on the main unit and molded section of the solid state relay, radio pliers should be used to grasp the terminals between the point of bending and the molded case when making the bends. • Thermal design When a heat sink is mounted on the 10 A type The heat sink (AQ1801) or a radiator which can make good contact should be used. If a heat sink is used in which the contact condition is bad, a heat conducting compound should be used to improve the heat radiation. (Ex. Momentive Performance...
Open the catalog to page 6Control voltage - -source T SAFETY WARNINGS • Do not use the product under conditions that exceed the range of its specifications. It may cause overheating, smoke, or fire. • Do not touch the recharging unit while the power is on. There is a danger of electrical shock. Be sure to turn off the power when performing mounting, maintenance, or repair operations on the relay (including connecting parts such as the terminal socket and socket). 1. Derating design Derating is a significant factor for reliable design and product life. Even if the conditions of use (temperature, current, voltage,...
Open the catalog to page 7Load power supply 9. Ripple in the input power supply If ripple is present in the input power supply, observe the following: 1) Current-sensitive type (Phototriac Coupler, AQ-H) (1) For LED forward current at Emin, please maintain the value mentioned at “Recommended input current.” (2) Please make sure the LED forward current for Emax. is no higher than 50 mA. 2) Voltage-sensitive type (AQ-G, AQ1, AQ8, AQ-J, AQ-A) (1) The Emin. should exceed the minimum rated control voltage (2) The Emax. should not exceed the maximum rated control voltage 10. When the input terminals are connected with...
Open the catalog to page 8Cautions for Use of Solid State Relays Cautions for Use of Solid State Relays 14. Soldering 1) When soldering surface-mount terminals, the following conditions are recommended. (1) IR (Infrared reflow) soldering method (Recommended condition reflow: Max. 2 times, measurement point: soldering lead) (2) Other soldering methods Other soldering methods (VPS, hot-air, hot plate, laser heating, pulse heater, etc.) affect the relay characteristics differently, please evaluate the device under the actual usage. (3) Soldering iron method Tip temperature: 350 to 400°C 662 to 752°F Wattage: 30 to 60 W...
Open the catalog to page 9Cautions for Use of Solid State Relays 18. The following shows the packaging format 1) Tape and reel (Phototriac coupler) Type Tape dimensions (Unit: mm inch) Dimensions of paper tape reel (Unit: mm inch) 21±0.8 .827±.031 Tractor feed holes 1.55±0.05 dia. .061±.002 dia. Device mounted on tape 2.8±0.3 .110±.012 ±0.1 (1) When picked from 1/2-pin side: Part No. APT❍❍❍❍SX (Shown above) (2) When picked from 3/4-pin side: Part No. APT❍❍❍❍SZ Tractor feed holes 1.5 ±0.1 dia. −0 .059±.004 dia. −0 Device mounted on tape 12±0.1 .472±.004 (1) When picked from 1/2-pin side: Part No. APT❍❍❍❍AX (2) When...
Open the catalog to page 10Cautions for Use of Solid State Relays 2) Tape and reel (AQ-H) Type Tape dimensions (Unit: mm inch) Dimensions of paper tape reel (Unit: mm inch) 21±0.8 .827±.031 80±1 dia. 3.150±.039 dia. Device mounted on tape 12±0.1 .472±.004 (1) When picked from 1/2/3/4-pin side: Part No. AQH❍❍❍❍AX (Shown above) (2) When picked from 5/6/8-pin side: Part No. AQH❍❍❍❍AZ 3) Tube Phototriac coupler and AQ-H SSR are packaged in a tube as pin No. 1 is on the stopper B side. Observe correct orientation when mounting them on PC boards. Snubber Circuit 1. Reduce dv/dt An SSR used with an inductive load can...
Open the catalog to page 11All Matsushita Electric Works catalogs and technical brochures
-
Narrow pitch RF connectors
12 Pages
-
High Current Connectors
12 Pages
-
Ultra-slim Photoelectric Sensor
16 Pages
-
Laser Distance Sensor
16 Pages
-
CA RELAYS
8 Pages
-
AQ-J RELAYS
19 Pages
-
AQ-H RELAYS
14 Pages
-
AQ-G RELAYS
14 Pages
-
AQ-A RELAYS (DC output type)
15 Pages
-
AQ-A RELAYS (AC output type)
17 Pages
-
AQ8 RELAYS
17 Pages
-
HG-S series
18 Pages
-
HE
6 Pages
-
SFD-WL3
2 Pages
-
SF4D
42 Pages
-
ELC500
8 Pages
-
AC Fan Motor 80×38t
1 Pages
-
GT707
2 Pages
-
GT SERIES
24 Pages
-
GT32-R
2 Pages
-
Shin-G Series
293 Pages
-
MINAS-BL KV Series
52 Pages
-
LP-GS series
12 Pages
-
LP- V SERIES, LP- W SERIES
16 Pages
-
LP-M
12 Pages
-
ER-VW
8 Pages
-
ER-TF SERIES
6 Pages
-
ER-X001
4 Pages
-
EWA2
8 Pages
-
RJ RELAYS (ARJ)
5 Pages
-
SF Relays
4 Pages
-
mechDE Relays (ADE)
4 Pages
-
EX-L200
12 Pages
-
gtseries_e_cata
24 Pages
-
ce_up50_1
6 Pages
-
digest_e_cata
32 Pages
-
fx-100
20 Pages
-
uj30
12 Pages
-
Power relay selector chart
8 Pages
-
NEW & KEY PRODUCTS 2012
32 Pages
-
Aicure UJ30/35 Catalog
12 Pages
-
KW2G-H
4 Pages
-
LP-S series
12 Pages
-
LP-S500W
12 Pages
-
SC-GU3
8 Pages
-
SL-PK01
2 Pages
-
DPC-L100/DPH-L100
12 Pages
-
FP-X0
8 Pages
-
FPOR
20 Pages
-
PM 2
6 Pages
-
PM-24
6 Pages
-
LP-Z Series
4 Pages
-
LP-V/W Series
16 Pages
-
FP2SH
24 Pages
-
LP-300 Series
12 Pages
-
SF4B Ver.2
48 Pages
-
SL-VGU1-485
2 Pages
-
PM-44/PM-54
10 Pages
-
PV200
22 Pages
-
FX-500
20 Pages
-
Flat Type Fiber
2 Pages
-
LP-400 Series
16 Pages
-
MIPTEC catalog
8 Pages
-
PM-64
8 Pages
Archived catalogs
-
Lighting Control Catalog
42 Pages
-
Time Switches
2 Pages
-
Time & Synchronization VIC100
1 Pages
-
GPS Products Antennas
2 Pages
-
Phototriac Coupler
4 Pages
-
Signal Relays
31 Pages