AQ-A RELAYS (AC output type) - 1

Automation Controls Catalog Solid State Relays AQ-A RELAYS (AC output type) Load current 15 to 40 A Small Screw Terminal SSR us • Compact size: W 40 x L 58 x H 25.5 mm • With terminal cover for safety (output side only) Note: Cover on input side available as option. • Mounting pitch: 47.5 mm • Built in varistor for excellent surge absorption • With LED indication for operation status verification • Safety standards • C-UL (UL508, UL60950-1) certified • VDE (EN60950-1) reinforced insulation certified TYPICAL APPLICATIONS • Heater control • Business use: Cooking machine, Vending machine, Freezer and Refrigerator • Industrial use: Molding machine, Temperature controlled bath, Printing machine and Packing machine ORDERING INFORMATION (PART NO.) ^Control voltage Functions 1: 4 to 32 V DC VL: Built-in varistor and LED indication * Random type is available by custom order. ■ AQ-ASolid State Relays

Open the catalog to page 1
AQ-A RELAYS (AC output type) - 2

■ Ratings (Measurement condition: at 20°C, Input ripple: 1% or less) Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ 2

Open the catalog to page 2
AQ-A RELAYS (AC output type) - 3

Solid State Relays AQ-A RELAYS (AC output type) Tested condition: Without external heat sink With external heat sink If the mounting surface is not metallic and a heat sink is not used, When using standard heat sink (AQF-HS-J25A, AQP-HS-30/40A, AQP-HS-)10A, AQP-HS-S)20A) expose the bottom surface and plate surface to improve heat dissipation. 1) If attached to a heat sink, use a heat conductive compound (Ex. Momentive Performance Materials Inc. YG6111 or TSK5303) of similar coating to improve cooling. 2.Non-repetitive surge current vs. carrying 3.Input current vs. input voltage...

Open the catalog to page 3
AQ-A RELAYS (AC output type) - 4

Solid State Relays AQ-A RELAYS (AC output type) OPTION Slim heat sink (AQP812) Mounting hole pattern External dimensions (Effective screw depth: 6 mm) “A” part Note: When using on a DIN rail, please install so that the “A” part is on top. Standard heat sink (AQP811) Mounting hole pattern External dimensions Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/

Open the catalog to page 4
AQ-A RELAYS (AC output type) - 5

Solid State Relays AQ-A RELAYS (AC output type) Standard heat sink (AQP804) Mounting hole pattern External dimensions Standard heat sink (AQP808) Mounting hole pattern External dimensions Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/

Open the catalog to page 5
AQ-A RELAYS (AC output type) - 6

External dimensions ■ Mounting rail (ATA48011) ■ Fastening plate (ATA4806) ^Terminal cover (AQA801) CN SCHEMATIC AND WIRING DIAGRAMS 4 O- Output configuration Wiring diagram INPUT LOAD Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ 6

Open the catalog to page 6
AQ-A RELAYS (AC output type) - 7

Solid State Relays AQ-A RELAYS (AC output type) Solid State Relays AQ-A RELAYS (AC output type) Space saving requiring only a depth of 56 mm Recommended Temperature Controllers ■ KT4H Temperature Controller • Data collection possible through a PLC using RS485 communication • Tool port is standard for easy data setting • Inverted LCD + backlight for good legibility with large characters • Excellent operability and rich optional control functions [Substitute part numbers] Note: For detailed product information about temperature controllers, please refer to our website: URL...

Open the catalog to page 7
AQ-A RELAYS (AC output type) - 8

Control voltage - -source T SAFETY WARNINGS • Do not use the product under conditions that exceed the range of its specifications. It may cause overheating, smoke, or fire. • Do not touch the recharging unit while the power is on. There is a danger of electrical shock. Be sure to turn off the power when performing mounting, maintenance, or repair operations on the relay (including connecting parts such as the terminal socket and socket). 1. Derating design Derating is a significant factor for reliable design and product life. Even if the conditions of use (temperature, current, voltage,...

Open the catalog to page 8
AQ-A RELAYS (AC output type) - 9

Load power supply 9. Ripple in the input power supply If ripple is present in the input power supply, observe the following: 1) Current-sensitive type (Phototriac Coupler, AQ-H) (1) For LED forward current at Emin, please maintain the value mentioned at “Recommended input current.” (2) Please make sure the LED forward current for Emax. is no higher than 50 mA. 2) Voltage-sensitive type (AQ-G, AQ1, AQ8, AQ-J, AQ-A) (1) The Emin. should exceed the minimum rated control voltage (2) The Emax. should not exceed the maximum rated control voltage 10. When the input terminals are connected with...

Open the catalog to page 9
AQ-A RELAYS (AC output type) - 10

Cautions for Use of Solid State Relays Cautions for Use of Solid State Relays 14. Soldering 1) When soldering surface-mount terminals, the following conditions are recommended. (1) IR (Infrared reflow) soldering method (Recommended condition reflow: Max. 2 times, measurement point: soldering lead) (2) Other soldering methods Other soldering methods (VPS, hot-air, hot plate, laser heating, pulse heater, etc.) affect the relay characteristics differently, please evaluate the device under the actual usage. (3) Soldering iron method Tip temperature: 350 to 400°C 662 to 752°F Wattage: 30 to 60 W...

Open the catalog to page 10
AQ-A RELAYS (AC output type) - 11

Cautions for Use of Solid State Relays 18. The following shows the packaging format 1) Tape and reel (Phototriac coupler) Type Tape dimensions (Unit: mm inch) Dimensions of paper tape reel (Unit: mm inch) 21±0.8 .827±.031 Tractor feed holes 1.55±0.05 dia. .061±.002 dia. Device mounted on tape 2.8±0.3 .110±.012 ±0.1 (1) When picked from 1/2-pin side: Part No. APT❍❍❍❍SX (Shown above) (2) When picked from 3/4-pin side: Part No. APT❍❍❍❍SZ Tractor feed holes 1.5 ±0.1 dia. −0 .059±.004 dia. −0 Device mounted on tape 12±0.1 .472±.004 (1) When picked from 1/2-pin side: Part No. APT❍❍❍❍AX (2) When...

Open the catalog to page 11
AQ-A RELAYS (AC output type) - 12

Cautions for Use of Solid State Relays 2) Tape and reel (AQ-H) Type Tape dimensions (Unit: mm inch) Dimensions of paper tape reel (Unit: mm inch) 21±0.8 .827±.031 80±1 dia. 3.150±.039 dia. Device mounted on tape 12±0.1 .472±.004 (1) When picked from 1/2/3/4-pin side: Part No. AQH❍❍❍❍AX (Shown above) (2) When picked from 5/6/8-pin side: Part No. AQH❍❍❍❍AZ 3) Tube Phototriac coupler and AQ-H SSR are packaged in a tube as pin No. 1 is on the stopper B side. Observe correct orientation when mounting them on PC boards. Snubber Circuit 1. Reduce dv/dt An SSR used with an inductive load can...

Open the catalog to page 12

All Matsushita Electric Works catalogs and technical brochures

  1. CA RELAYS

    8 Pages

  2. AQ-J RELAYS

    19 Pages

  3. AQ-H RELAYS

    14 Pages

  4. AQ-G RELAYS

    14 Pages

  5. AQ8 RELAYS

    17 Pages

  6. AQ1 RELAYS

    16 Pages

  7. HG-S series

    18 Pages

  8. HE

    6 Pages

  9. SFD-WL3

    2 Pages

  10. SF4D

    42 Pages

  11. ELC500

    8 Pages

  12. GT707

    2 Pages

  13. GT SERIES

    24 Pages

  14. GT32-R

    2 Pages

  15. Shin-G Series

    293 Pages

  16. LP-GS series

    12 Pages

  17. LP-M

    12 Pages

  18. ER-VW

    8 Pages

  19. ER-TF SERIES

    6 Pages

  20. ER-X001

    4 Pages

  21. EWA2

    8 Pages

  22. SF Relays

    4 Pages

  23. EX-L200

    12 Pages

  24. ce_up50_1

    6 Pages

  25. digest_e_cata

    32 Pages

  26. fx-100

    20 Pages

  27. uj30

    12 Pages

  28. KW2G-H

    4 Pages

  29. LP-S series

    12 Pages

  30. LP-S500W

    12 Pages

  31. SC-GU3

    8 Pages

  32. SL-PK01

    2 Pages

  33. FP-X0

    8 Pages

  34. FPOR

    20 Pages

  35. PM 2

    6 Pages

  36. PM-24

    6 Pages

  37. LP-Z Series

    4 Pages

  38. LP-V/W Series

    16 Pages

  39. FP2SH

    24 Pages

  40. LP-300 Series

    12 Pages

  41. SF4B Ver.2

    48 Pages

  42. SL-VGU1-485

    2 Pages

  43. PM-44/PM-54

    10 Pages

  44. PV200

    22 Pages

  45. FX-500

    20 Pages

  46. LP-400 Series

    16 Pages

  47. PM-64

    8 Pages

Archived catalogs

  1. Signal Relays

    31 Pages