XWR series
2Pages

{{requestButtons}}

Catalog excerpts

XWR series - 1

Twin Box Matsusada Prcision High power X-ray module XWR Series 01.163.011 17-1 umwn» IttTO»»» ■ FEATURES Wide lineup, 60kV to 130kV / 120W to 260W 镕 Continuous operation is available. Stable X-ray output Օ User-friendly operation ■SUMMARY XWR series is the 2-unit type X-ray module with high-stability power supply and X-ray tube.Compatible high power and compactness by our original thermal design technologies. Suitable for integration to the measurement equipment. *This picture is XTR-120-60. Other models have different appearance and dimensions. Please contact the nearest sales office for details. LINEUP Anode voltage MAX 60kV 80kV 100kV 130kV MIN 10kV 30kV 30kV 30kV Beam current 2mA 3mA 2mA 2mA Max Power 120W 240W 200W 260W Focal spot size 1mm 1mm 1mm 1mm Radiation angle 20° 60° 60° 60° Window material Glass Operation Continuous Dimension WxDxH (mm) Controller unit 8.35x12.99x5.51 (212x330x140) 18.98x24.02x5.24 (482x610x133) 18.98x24.02x5.24 (482x610x133) 18.98x24.02x6.97 (482x610x177) X-ray unit 5.12x10.75x6.97 (130x273x177) 8.11x18.90x8.86 (206x480x225) 8.11x18.90x8.86 (206x480x225) 8.11x18.90x8.86 (206x480x225) Weight (kg approx) Controller unit 10 15 15 20 X-ray unit 6 20 20 20 Model XWR120-60 XWR240-80 XWR200-100 XWR260-130 ■ SPECIFICATIONS Input voltage 100VAC to 120VAC 50/60Hz single phase 200VAC to 240VAC 50/60Hz single phase (-L(200V)option) Output control Voltage Local : 10-turn potentiometer on front panel Remote : External control voltage 0 to 10Vdc (Input impedance more than 1MQ) or by external 5kQ potentiometer Current Local : 10-turn potentiometer on front panel Remote : External control voltage 0 to 10Vdc (Input impedance more than 1MQ) or by external 5kQ potentiometer Display Output voltage : 3%-digit digital meter Output current : 3%-digit digital meter LED display of the status of X-ray ON/OFF, STNDBY, INTERLOCK and AGING Monitor output Output voltage monitor : 10V/Maximum output voltage (Output impedance 1kQ) Output current monitor : 10V/Maximum output current (Output impedance 1kQ) Protections Over voltage protection Over current protection Protection against output short-circuit and arc discharge Filament protection Blackout protection Over temperature protection Remote switch ON/OFF Interlock by door switch Output status signal output 0 to +40°C 0 to +50°C 30% to 80%RH (no condensation) AC line input cable 2.5m (1) Shielded HV output cable 2.5m (1) Instruction manual (1) Other functions Operating temp. Storage temp. Humidity Accessories

Open the catalog to page 1
XWR series - 2

XWR Series ■ OPTION 063.0H 172 -L(200V) 200VAC to 200VAC single phase input Warranty We warrant that products contained in this catalog (hereinafter, the "Products") are free from defects in material and workmanship under normal use for a period of one (1) year from the date of shipment thereof. However, the warranty period for X-ray detectors and X-ray source shall be either one (1) year from the date of shipment or 1,000 hours, whichever shorter.The above warranty shall not apply to any Product which, at our sole judgment, has been:i)Repaired or altered by persons unauthorized by us; or...

Open the catalog to page 2

All Matsusada catalogs and technical brochures

  1. W series

    3 Pages

  2. RC series

    2 Pages

  3. TP series

    1 Pages

  4. TZ series

    2 Pages

  5. TG series

    2 Pages

  6. TF series

    1 Pages

  7. PZJ series

    2 Pages

  8. X series

    1 Pages

  9. XR series

    1 Pages

  10. Xg Series

    4 Pages

  11. AMP series

    4 Pages

  12. DRA series

    5 Pages

  13. DOS series

    8 Pages

  14. VOL Series

    12 Pages

  15. ECA series

    2 Pages

  16. KA-R series

    3 Pages

  17. EJC series

    2 Pages

  18. TA/TC Series

    2 Pages