XR series
1Pages

{{requestButtons}}

Catalog excerpts

XR series - 1

aMc Matsusada Prcision X-ray Power Supplies XR Sries 30kV, 50kV, 65kV 50W to 100W 1016-07Pa ■ FEATURES 驕 For grounded Cathode X-ray Tubes. Compact High Power 50W to 100W. Օ 0.05% Emission current regulation. Remote and local emission control. Օ Adjustable filament current. Safety interlock. Օ Overvoltage and short circuit protection. CE certified for 50W and 75W of 50kV model. ■ APPLICATIONS This compact module incorporates adjustable beam, bias and filament supplies for low power X-ray applications. High voltage and filament current ramp up linearly for fast starts. Constant emission current is adjustable from 0 to full output for precise emission control. Output Voltage (kVdc) Output Current (mA) Model* Input Current (A max) Filament Supply 0 to +30 1.67 XR-305-50-## 4 0.3 to 3.5Adc,adjustable. Compliance Voltage 4.5V (9W max) 0 to +50 1 XR-505-50- ## 4 1.5 XR-505-75- ## 6 2 XR-505-100- ## 8 0 to +60 1 XR-605-60- ## 4.8 0 to +65 0.77 XR-655-50- ## 4 ■ SPECIFICATIONS OPTION LB Bias Supply 0V to -300V adjustable, output current 0.25mA LGH LGH-3I connector Please ask for CE marked models Input Voltage Voltage control 24V ±10% Local : via internal multi-turn trimmer Remote : via external voltage source 0 to 10V (Accuracy ±1%, Input impedance 10MQ) Local : via internal multi-turn trimmer Remote : via external voltage source 0 to 10V (Accuracy ±1%, Input impedance 10MQ) Line : ±0.01% Load : ±0.01% 0.2%p-p 0.05% / 8Hr for Voltage and Current 0.01% / °C 0°C to + 50°C Voltage monitor : 0 to 10V, ±1% accuracy, output impedance 1kQ Current monitor : 0 to 10V, ±1% accuracy, output impedance 1kQ Three Phoenix screw terminals and one 9pin mini D-type connector for INPUT, remote control, monitor output, filament and bias output. Short to GND through a 12V lamp : HV/ON OPEN : HV/OFF Over voltage, Over current protection. Arc, Short circuit Emission Control Add " -L " to the model number when ordering. (i.e.) XR-505-50-01-LBGH Regulation Ripple Stability Temperature Coef. Operating Temperature Monitor Output I/O connectors Interlock Protection Shielded HV output cable Pdart# CN-XR(1.5) 58.5"(1.5m)flying lea ( Whe n a co nnecto r of t h e s u i tab l e X- ray ) tube is required, please contact us. / ■ DIMENSIONS inch(mm) 9.5" x 3.3" x 5.5"(240 x 83.5 x 140) Note : These specifications are at the maximum rated output after a YzHr warm-up period unless otherwise specified. aMc Matsusada Prթcision Inc. For products) www.matsusada.com/product For contacta www.matsusada.com/contact San Jose Office : 2570 N.First Street Suite 200 San Jose, CA 95131 Dallas Office : 5430 LBJ Freeway, Suite 1200 Dallas, TX 75240 Headquarters : 745 Aoji-cho Kusatsu Shiga 525-0041 Japan Tel: +1-408-273-4573 Fax: +1-408-273-4673 Tel: +1-972-663-9336 Fax: +1-972-663-9337 Tel: +81-77-561-2111 Fax: +81-77-561-2112 New York Office : 80 Orville Drive Suite 100 Bohemia, NY 11716 Chicago Office : 2275 Half Day Road, Suite 350 Bannockburn, IL 60015 Tel: +1-631-244-1407 Fax: +1-631-244-1496 Tel: +1-847-821-2788 Fax: +1-847-821-2789

Open the catalog to page 1

All Matsusada catalogs and technical brochures

  1. W series

    3 Pages

  2. RC series

    2 Pages

  3. TP series

    1 Pages

  4. TZ series

    2 Pages

  5. TG series

    2 Pages

  6. TF series

    1 Pages

  7. PZJ series

    2 Pages

  8. XWR series

    2 Pages

  9. X series

    1 Pages

  10. Xg Series

    4 Pages

  11. AMP series

    4 Pages

  12. DRA series

    5 Pages

  13. DOS series

    8 Pages

  14. VOL Series

    12 Pages

  15. ECA series

    2 Pages

  16. KA-R series

    3 Pages

  17. EJC series

    2 Pages

  18. TA/TC Series

    2 Pages