CO series: Digital controller
8Pages

{{requestButtons}}

Catalog excerpts

CO series: Digital controller - 1

^ Matsusada Prcision DIGITAL CONTROLLER CO Sries CO s驩ries Ehternet supported modules makes possible the construction of large-scale system

Open the catalog to page 1
CO series: Digital controller - 2

The CO sries is a line of adapters used to digitally control Matsusada's High Voltage, DC, and AC power supplies via personal computer. In addition to enabling manufacturing line automation and speeding up R&D, the CO series is ideallysuited to building safe, stable, varsatile and highly accurate automatic inspection and measurement systems, saving your time and cutting labor costs. The addition of an ethernet supported module to our product lineup makes large-scale systems and remote location control possible. The CO series utilizes fiber optic cables for the digital communication,...

Open the catalog to page 2
CO series: Digital controller - 3

* Please contact near by sales office for AC power supplies, Electric Load, and the others which is not listed below. Power Supply RE series RG series AU,AF,AE,ES,EQ, W,K12-R,XR series* type Power supply integrated interface Optical communication Optical communication Optical communication with USB -LUsl option CO-U32 CO-U32 CO-U32 with RS-232C CO-OPT2-25 CO-OPT2-9 CO-OPT2-25 CO-OPT2-9 CO-OPT2-25 CO-OPT2-9 Adapters1 with RS-485 -LGb option CO-OPT4-25 CO-OPT4-25 CO-OPT4-25 with GPIB CO-G32 CO-G32 CO-G32 with Ethernet -LEt option CO-E32 CO-E32 CO-E32 Adapters2 (Combine with Adapters 1) -LGob...

Open the catalog to page 3
CO series: Digital controller - 4

Constitution Combination with power supplies refer to section of the accessories for A to D Configuration example of DC power supplies(RK-80, R4K-80, R4K-36, RK,REK) RK, REK option -LEt -LUsl RK-80, R4K-80, R4K-36,RK and REK opti Ethernet JE3 RK,REK Power supply System when controls RK and REK with Ethernet. A hub will be required between computer and RK and REK when control several RK and REK units. Full-controll type with control features and status features. It enables you to configure the system with many units at low cost. System when control RK-80, R4K-80, R4K-36, RK and REK with USB....

Open the catalog to page 4
CO series: Digital controller - 5

AC power supplies, Electrical loads can be connected. Please contact near by sales office for dtail. Connection with DC power supplies / HV power supplies Ethernet Adapter 1 Adapter 2 (up to 32 units) DCPS option: -LGob RE DC power supplies / HV power supplies CO-E32 A |Application| Ideal system for application controlling one or several RE with Ethernet, USB, GPIB, RS-232C, or RS-485. | Connection Adapter 1 is to be connected to RE with dedicated optical fiber cable. |Number of uniq Up to 32 units of RE series can be connected with 1 Adapter 1. In case of GPIB maximum 448 units (14 address...

Open the catalog to page 5
CO series: Digital controller - 6

Accessories / Interface spcifications | Accessories CO-G32,CO-G32m,CO-RG,CO-HV CO-U32,CO-U32m,CO-E32,CO-E32m , . .. .. , ,,, .-, , , , . ... 1 Ruber foot will be glued on depending on \ Instruction ManLJa1 (1), Rubber feet (4) installation method. J -LGmb Modular cable(Case © ) CO-M cable (1) Opt cable(Case ®) Standard : CO-OPT cable 1 (2m length) -L(Fc#) option : CO-OPT cable 1 (#m length)---See page3. CO-RG Control cable(Case(B)) Standard: CO-RG cable (1) Option -LH: CO-RGH cable (1) ! Option -LH is required for CO-RG unit when combined with RG series of over 120V voltage. | 1 When...

Open the catalog to page 6
CO series: Digital controller - 7

Dimensions inch(mm) CO-G32.CO-U32,CO-E32,CO-G32m,CO-U32m,CO-E32m,CO-RG,CO-HV CO-G32,CO-U32,CO-E32 CO-G32m,CO-U32m,CO-E32m (Front) CO-G32 <Rear> CO-U32 <Rear> CO-E32 <Rear> OJ co 8. -© ©- B © © l\m\ ® - O ©- ®© o'"(> ® 5.91(150) 1.10 3.94(100) CO t CO-G32m <Rear> CO-U32m <Rear> CO-E32m CO-RG/CO-HV CO-RG/CO-HV <Rear> <Front> <Rear> <0>- O TLK O Le" ®- © © -® screw M3X2 ®- ® -© ©-©- ®© o O- ®© » o- ® - o -o O- ® -o O- CE POWER LED (2 POWER ON/OFF switch (3 ADDRESS switch ® IEEE-488 connector (5 Opt fiber connector(OUT) (6 GROUND terminal (7 AC input (I USB connector (9 Module cable...

Open the catalog to page 7
CO series: Digital controller - 8

USA/canada : + 1-888-652-8651 other countries : +81-6-6150-5089 'usto Please copy this page and above fax number after filling out form below. I would like □ A quotation □ An explanation of product □ A demonststration □ To purchase □ Other ( ) Give us your requirement / comment Please fill in below. Address: Company: Dept.: Title: Name: Tel: Fax: E-mail: We warrant that products contained in this catalog (hereinafter, the "Products") are free from defects in material and workmanship under normal use for a period of one (1) year from the date of shipment thereof. However, the warranty period...

Open the catalog to page 8

All Matsusada catalogs and technical brochures

  1. W series

    3 Pages

  2. RC series

    2 Pages

  3. TP series

    1 Pages

  4. TZ series

    2 Pages

  5. TG series

    2 Pages

  6. TF series

    1 Pages

  7. PZJ series

    2 Pages

  8. XWR series

    2 Pages

  9. X series

    1 Pages

  10. XR series

    1 Pages

  11. Xg Series

    4 Pages

  12. AMP series

    4 Pages

  13. DRA series

    5 Pages

  14. DOS series

    8 Pages

  15. VOL Series

    12 Pages

  16. ECA series

    2 Pages

  17. KA-R series

    3 Pages

  18. EJC series

    2 Pages

  19. TA/TC Series

    2 Pages