1. Catalogs
  2. Marzocchi Pompe
  3. ALP_GHP aluminium and aluminium/cast iron multiples modular pumps

ALP_GHP aluminium and aluminium/cast iron multiples modular pumps

ALP_GHP aluminium and aluminium/cast iron multiples modular pumps
1 / 52 PagesView full catalog

ALP_GHP aluminium and aluminium/cast iron multiples modular pumps

Product catalog summary
General Information
Marzocchi Pompe, established in 1961, is a prominent manufacturer of external gear hydraulic pumps and motors, part of the Marzocchi Group with over 400 employees. The company specializes in hydraulic pumps, motors, and suspension systems.
Basic Design
Marzocchi's external gear pumps are available in single or multiple stages, known for their versatility, durability, and cost-effectiveness due to simple construction. Made from high-quality materials like aluminum and special steel, they minimize deformation under high pressure and reduce internal leakage for efficient operation.
Product Range
The company offers five families of modular gear pumps with various displacements by altering gear width. Different flanges, shafts, and ports are available, with specific needs advised to be discussed with the technical department.
Special Versions
Special pump versions are available for high-temperature, low-temperature, and high-pressure applications, identified by specific codes and requiring consultation with the technical department for suitability.
Technical Information and Recommendations
Optimal performance and longevity require adherence to installation and usage guidelines, including proper hydraulic system design, filtration, and contamination avoidance. Power absorption of the pump's front element should be greater than or equal to that of the rear or intermediate elements in multi-stage pumps. Maximum rotational speed and operating pressures are determined by the weakest system element.
Overview
The document provides guidelines for optimal operation and longevity of Marzocchi modular pumps, emphasizing proper hydraulic system design, assembly, and maintenance, focusing on components like intake, delivery, and return pipes, and system parts such as valves, filters, tanks, heat exchangers, and accumulators.
Recommendations for Correct Use
Ensure the power absorbed by the front stage is greater than or equal to that of subsequent stages, adhere to maximum rotation speed, and limit operating pressures based on maximum torque values. Refer to specific catalogues for torque values for different pump series.
Installation Notes
Before starting the system, ensure the pump's rotation direction matches the drive shaft, align pump and motor shafts properly, protect the drive shaft seal during painting, keep intake and return pipes below fluid level, fill the pump with fluid manually, and bleed air from the circuit during startup.
Cleaning and Filtering the System
Preventive and corrective measures should be taken to maintain fluid cleanliness, including proper system cleaning during assembly, pre-filtering fluids, and using filters with appropriate absolute filtering power and β filtering ratio.
Hydraulic Fluids
Use mineral oil-based hydraulic fluids with anti-wear, anti-foaming, antioxidant, anti-corrosion, and lubricating properties, complying with DIN 51525 and VDMA 24317 standards. Fluid temperature should range between -10°C and +80°C, with kinematic viscosity within specified limits.
Inlet Pressure and Lines
Maintain inlet pressure between 0.7 and 3 bars (absolute), avoid sudden changes in pipe direction, sharp bends, and disproportionate lengths, and ensure fluid velocity does not exceed recommended values.
Minimum Rotation Speed
Marzocchi pumps offer flexibility in rotation speeds, with minimum rotation speeds varying by model and specified in product tables.
Pressure Definition
Product tables define three maximum pressure levels (P1, P2, P3) for pump operation, with P3 being the peak maximum pressure.
Specifications
The document describes external gear modular pumps, detailing specifications and selection criteria, including tables for modular single stages of micropumps and ALP and GHP series.
Procedures
To connect the pump to the motor, use a flexible coupling to avoid transmitting radial or axial forces to the pump shaft, which could lead to early wear. Regular lubrication is necessary to prevent wear.
Standards and Recommendations
Marzocchi modular multiple pumps are monodirectional, with rotation direction defined by the driving shaft position. Middle stages depend on assembly for direction.
Formulas
Formulas are provided for calculating fluid velocity, delivered flow rate, absorbed torque, and absorbed power, depending on factors like flow rate, displacement, rotation speed, and efficiency values.
Performance and Efficiency
Efficiency values depend on pressure differential, rotation speed, fluid characteristics, and filtration degree. Contact the technical department for precise efficiency data.
Ordering Information
Examples are provided for ordering modular elements, specifying rotation, displacement, shaft type, port type, and seals, with options for reinforced shaft seals and high-pressure applications.
Specifications
The document outlines specifications for different pump models, including displacement, flow rate, maximum pressures, maximum speed, and dimensions, with detailed tables for each pump type.
Accessories
Standard pumps come with accessories like a woodruff key, hexagonal nut, and washer, with specified thread depths for standard ports.
Ordering Information
Examples of ordering different pump elements are provided, specifying series, group, rotation direction, displacement, shaft type, port type, and seals.
Recommendations
For more detailed information on availability and delivery terms, contact the sales and technical department, and refer to specific catalogues for additional configurations.
Specifications
Detailed specifications for various pump models in the GHPP3 and ALP series are provided, including displacement, flow rate, maximum pressure, maximum speed, and dimensions.
Ordering Instructions
Examples of ordering different pump elements are included, specifying series, group, rotation direction, displacement, shaft type, port type, and seals.
Assembly Guidelines
Modular multiple pumps can be assembled using kits or pre-assembled, with assembly rules stating that the preceding stage must be equal to or larger than the following stage in terms of group and displacement.
Assembly Kits and Spare Parts
Components of assembly kits are listed, including coupling, adjustment ring, gasket, screw, and nut, with torque settings and part numbers for standard and special version kits.
Separate and Common Inlets
Standard pumps have communicating input areas, but the AS option allows for separate inlets for different stages, and the AC option allows for a common inlet among elements.
Additional Information
For more details on availability and delivery terms, contact the sales and technical department. Different configurations of flanges, shafts, and ports are available beyond the standard options listed.
Overview
The document describes specifications and ordering information for Marzocchi's modular multiple pumps, specifically the GHPA2-D-25-AC+GHPP2-D-16-AC model, a two-stage pump with a common inlet port.
Specifications
The pumps are part of the GHP series, available for families 1, 2, and 3, with each stage having an output port and two or more adjoining stages sharing a single input port.
Ordering Information
The AC option allows for a common input port shared among stages, specified in the ordering process.
Limitations
Models have a limited number of available sizes and port types. Special applications requiring high reliability must be specified in the order and receive written approval from Marzocchi.
Disclaimer
Marzocchi disclaims responsibility for errors in the catalog and reserves the right to change technical specifications without notice. Data provided is for informational purposes only.
Contact Information
Contact details for Marzocchi in Italy and the USA are provided for further inquiries.
See more

Catalog excerpts

ALP_GHP aluminium and aluminium/cast iron multiples modular pumps-1

HIGH PRESSURE GEAR PUMPS POMPE MULTIPLE MODULARI ad INGRANAGGI MULTIPLE MODULAR GEAR PUMPS

 Open the catalog to page 1
ALP_GHP aluminium and aluminium/cast iron multiples modular pumps-2

Marzocchi Pompe fu fondata nel 1961 da Guglielmo e Stefano Marzocchi a Casalecchio di Reno, nelle vicinanze di Bologna. Oggi, Marzocchi Pompe è la capofila di un gruppo industriale il “Gruppo Marzocchi” che occupa più di 400 persone. Il Gruppo, di proprietà e diretto da Adriano e Paolo Marzocchi, opera nei settori delle pompe e dei motori idraulici e dei sistemi di sospensione per motociclette e mountain bikes. Marzocchi Pompe ha sviluppato nel corso degli anni le sue dimensioni e la sua gamma di prodotti, arrivando ad essere oggi uno dei maggiori produttori di pompe e di motori idraulici ad...

 Open the catalog to page 2
ALP_GHP aluminium and aluminium/cast iron multiples modular pumps-3

CONTENUTO pagina / pages Informazioni generali 2 General information Progetto di base 2 Basic design Gamma di prodotto 4 Product range Versioni speciali 5 Special versions Informazioni tecniche 6 Technical information Note per l'utilizzo Note per l'installazione Pulizia dell'impianto e filtrazione Fluidi idraulici Pressione in aspirazione Condotti d'aspirazione e mandata Velocita minima di rotazione Definizione delle pressioni Senso di rotazione Traino Formule di uso corrente Elementi modulari monodirezionali 6 Reccomendation for correct use 7 Installation notes 8 Cleaning and filtering the system 9...

 Open the catalog to page 3
ALP_GHP aluminium and aluminium/cast iron multiples modular pumps-4

INFORMAZIONI GENERALI GENERAL INFORMATION PROGETTO DI BASE La pompa ad ingranaggi esterni sia in configurazione singola che multipla (a due o più stadi) è uno dei componenti maggiormente impiegato nei moderni impianti oleodinamici. Essa unisce in sé caratteristiche di versatilità, resistenza, lunga durata. La semplicità nella costruzione permette costi d'acquisto e di manutenzione contenuti. Il consolidamento di questi concetti base, uniti alla continua evoluzione dei prodotti, allo sviluppo della progettazione e della ricerca basate su decenni d'esperienza, alla precisa scelta dei materiali,...

 Open the catalog to page 4
ALP_GHP aluminium and aluminium/cast iron multiples modular pumps-6

PRODUCT RANGE GAMMA DI PRODOTTO Le pompe modulari ad ingranaggi Marzocchi sono prodotte in cinque differenti gruppi. All'interno di ognuno, le diverse cilindrate si ottengono variando lo spessore di fascia dentata dell'ingranaggio. La nostra gamma di produzione permette di poter scegliere diverse opzioni di flange, alberi e porte d'aspirazione e mandata. Esse non sono esplicitamente indicate sulla presente non esaustiva pubblicazione pertanto, fare riferimento alle tavole sinottiche presenti sulle pubblicazioni dedicate alle pompe singole della serie ALP e GHP. Per maggiori dettagli sulle disponibilita...

 Open the catalog to page 6
ALP_GHP aluminium and aluminium/cast iron multiples modular pumps-7

VERSION! SPECIAL! SPECIAL VERSIONS Limitatamente ad alcuni gruppi e ad alcuni modelli, sono anche disponibili versioni per utilizzi speciali: For some groups and models are available special version for specific uses: "V" Versione per impieghi con fluido ad alte temperature. Campo di utilizzo da -10°C a +120°C. Tra -10°C e +80°C sono permesse P1, P2 e P3 come da tabella prodotto; oltre, non eccedere P1. "VV" Versione per impieghi con fluido ad alte temperature. Campo di utilizzo da -10°C a +150°C con pressione massima 20 bar. "ST" Versione per impieghi con fluido ad alte e basse temperature....

 Open the catalog to page 7
ALP_GHP aluminium and aluminium/cast iron multiples modular pumps-8

Per ottenere dalle pompe multiple modulari Marzocchi le migliori condizioni in termini di durata e prestazioni e consigliato seguire le raccomandazioni e i suggerimenti di installazione ed utilizzo indicate nel presente catalogo. Per quanto riguarda il sistema idraulico nel quale andra inserita la pompa, valgono alcune considerazioni generali: prestare molta cura nella progettazione e nella realizzazione dell'intero impianto, in special modo per quanto riguarda i condotti d'aspirazione, di mandata, di ritorno, e la posizione dei componenti presenti (valvole, filtri, serbatoi, scambiatori di calore,...

 Open the catalog to page 8
ALP_GHP aluminium and aluminium/cast iron multiples modular pumps-9

Prima di avviare I'impianto a regime, consigliamo di osservare alcuni semplici accorgimenti. • Verificare, nel caso di pompa monodirezionale, che il senso di rotazione sia coerente con quello dell'albero dal quale deriva il moto. • Controllare l'allineamento tra l'albero della pompa e l'albero del motore: e necessario che il collegamento non induca carichi assiali o radiali. • Proteggere l'anello di tenuta dell'albero della pompa in caso di verniciatura; verificare la pulizia nella zona di contatto tra anello di tenuta ed albero: la presenza di polvere puo accelerare le usure e causare delle...

 Open the catalog to page 9
ALP_GHP aluminium and aluminium/cast iron multiples modular pumps-10

PULIZIA DELL'IMPIANTO E FILTRAZIONE E ormai universalmente riconosciuto che la maggior parte dei prematuri cali di prestazioni delle pompe e dovuta ad un loro funzionamento con fluidi contaminati; l'estrema riduzione delle tolleranze che contraddistinguono i componenti delle pompe e il loro conseguente funzionamento con giochi ridotti, possono essere irrimediabilmente compromessi se non si pone estrema cura nel mantenere il fluido pulito. E comunemente accertato che le particelle circolanti continuamente nel fluido agiscono come agente abrasivo danneggiando le superfici con cui vengono a contatto...

 Open the catalog to page 10
ALP_GHP aluminium and aluminium/cast iron multiples modular pumps-11

FLUID! IDRAULICI HYDRAULIC FLUIDS Si raccomanda I'uso di fluidi specifici per circuiti idraulici a base d'olio minerale, con buone caratteristiche antiusura e antischiuma, con proprieta di rapida disareazione, antiossidanti, anticorrosione, lubrificanti e in grado di soddisfare quanto previsto dalla norma DIN 51525, dalla norma VDMA 24317 e di superare l'11° stadio della prova FZG. Per i modelli standard, la tempertura del fluido durante il funzionamento della pompa deve essere compreso tra -10°C e +80°C. I valori di viscosita cinematica del fluido sono i seguenti: Use specific mineral oil based...

 Open the catalog to page 11
ALP_GHP aluminium and aluminium/cast iron multiples modular pumps-12

VELOCITA MINIMA DI ROTAZIONE La versatile delle pompe Marzocchi e evidenziata anche dall'ampia varieta di regimi di rotazione ai quali e possibile sottoporle. I valori massimi sono presenti nelle tabelle di prodotto e variano in funzione del modello, mentre i valori minimi sono indicati nelle seguenti tabelle: Marzocchi pump flexibility is also highlighted by the wide selection of rotation speeds they can work at. Max. values are indicated in product tables and change according to the model, while min. values are as follows:

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.