The MM42 Digital Multimeter features a 3½ digit LCD with a maximum reading of 1999. It automatically indicates polarity and displays overrange with (1) or (-1). The device has an automatic zero function and a low battery indicator. It measures at a rate of 2.5 times per second and operates in environments from 0°C to 50°C with less than 70% relative humidity. It can be stored at temperatures from -20°C to 60°C with the battery removed. The multimeter is suitable for Category III installations within buildings and offers stated accuracy at 23°C ± 5°C with less than 75% relative humidity. It uses a single 9-volt battery with a typical life of 300 hours.

DC Volts:
Ranges include 2V, 20V, 200V, and 600V with a resolution of 1mV on the 2V range. Accuracy is ± (1.2% rdg + 1 dgt) with an input impedance of 1MΩ and overload protection up to 600VDC or AC rms.

AC Volts:
Ranges are 200V and 600V with a resolution of 100mV on the 200mV range. Accuracy is ± (2.0% rdg + 4 dgts) with an input impedance of 450kΩ and overload protection up to 600V DC or AC rms.

DC Current:
The range is 2A with a resolution of 1mA and accuracy of ± (2.5% rdg + 2 dgts). It is protected by a 2A/600V fast blow ceramic fuse.

Resistance:
Ranges include 200Ω, 2kΩ, 20kΩ, 200kΩ, and 2000kΩ with a resolution of 100mΩ on the 200Ω range. Accuracy varies from ± (1.5% rdg + 3 dgts) on the 200Ω range to ± (1.5% rdg + 1 dgt) on higher ranges. Overload protection is 500V DC or AC rms.

Diode Test:
Test current is 1.0mA ± 0.6mA with an accuracy of ± (3.0% rdg + 1 dgt) and open circuit volts of 3.3V dc typical. Overload protection is 500V DC or AC rms.

Transistor hFE:
Ranges from 0 to 1000hFE with a base current of approximately 10µA dc.

Battery Test:
Ranges are 1.5V and 9V with resolutions of 1mV and 10mV respectively. Accuracy is ± (3.0% rdg + 2 dgts) with loaded currents of 150mA for 1.5V and 6mA for 9V.

Accessories:
Includes a 2A 600V ceramic fuse, replacement leads, fused test leads to GS38 specification, and a soft foam-lined carry case.

Note:
Martindale Electric reserves the right to alter specifications without notice. This document is not part of any contract unless specifically included.
See more

Catalog excerpts

ENTRY LEVEL - MM42-1

DC VOLTSRanges: 2V, 20V, 200V, 600V Resolution: 1mV (on 2V range) Accuracy: (1.2% rdg + 1 dgt) Input impedance: 1M ѢĦ Overload protection: 600VDC or AC rms AC VOLTS: (50Hz - 500Hz) Ranges: 200V, 600V Resolution: 100mV (on 200mV range) Accuracy: (2.0% rdg + 4 dgts) Input impedance: 450k ѢĦ Overload protection: 600V DC or AC rms DC CURRENTRanges: 2A Resolution: 1mA Accuracy: (2.5% rdg + 2 dgts) Input protection: 2A/600V fast blow ceramic fuse > Accuracy: (1.5% rdg + 3 dgts) on 200 ѢĦ range (1.5% rdg + 1 dgt) on 2k > Open Circuit volts: 0.3V dc (3.0V dc on 200 Ω range) > DIODE TEST Test current: > Accuracy: ñ (3.0% rdg + 1 dgt) Open circuit volts: 3.3V dc typical Overload protection: 500V DC or AC rms TRANSISTORhFERanges: 0 - 1000hFE Base current: 10A dc approx. (Vce = 3.0V dc) BATTERY TESTRanges: 1.5V, 9V Resolution: 1mV, 10mV Accuracy: ձ (3.0% rdg + 2 dgts) Loaded Current: 150mA typical for 1.5V range6mA typical for 9V rangePower is supplied by a 9 volt "transistor" battery.(NEDA 1604, IEC 6F22, PP3) Accessories F1 - 1 x > 1 / > 4 2A 600V ceramicFUSE2600 (pack of 3) Replacement original leads - TL16 Fused test leads to GS38 specification - TL55 Soft foam lined carry case - TC55 > Due to policy of continuous development, Martindale Electric reserves the right to alter equipment specification and description outlined in this document without prior notice. No part ofthis document shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract. ԩ Martindale Electric Co. Ltd. 2001

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.