CM82/CM84

CM82/CM84

CM82/CM84

Product catalog summary
Specifications Overview:
The document provides detailed specifications for the CM82 and CM84 digital clamp meters. All specified accuracies are valid at 23°C ± 5°C and less than 70% relative humidity for one year. The temperature coefficient is 0.1 times the specified accuracy per °C within the range of 0°C to 18°C and 28°C to 50°C.

DC Voltage:
- Range: 400mV to 1000V
- Resolution: 0.1mV to 1V
- Input Impedance: >100M to 9.1M
- Accuracy: 0.5% + 2 digits
- Overload Protection: 1000V DC or 750V AC rms

AC Voltage:
- Range: 400mV to 750V
- Resolution: 0.1mV to 1V
- Input Impedance: >100M to 9.1M
- Accuracy: 1.5% + 5 digits
- Overload Protection: 1000V DC or 750V AC rms

AC Current:
- Range: 40A to 1000A
- Resolution: 0.01A to 1A
- Accuracy varies with frequency and current range
- Overload Protection: 1000A AC rms

DC Current (CM84 only):
- Range: 400A to 1000A
- Resolution: 0.1A to 1A
- Accuracy: 2.0% + 5 digits
- Overload Protection: 1000A DC

Resistance:
- Range: 400Ω to 40MΩ
- Resolution: 0.1Ω to 0.01MΩ
- Accuracy: 1.0% + 5 to 3.5% + 5 digits
- Overload Protection: 600V DC or AC rms

Capacitance (CM82 only):
- Range: 4nF to 4mF
- Resolution: 0.001nF to 0.001mF
- Accuracy: 3.0% + 15 to 5.0% + 10 digits
- Overload Protection: 600V DC or AC rms

Frequency:
- Range: 4kHz to 1MHz
- Resolution: 0.001kHz to 0.001MHz
- Accuracy: 0.1% + 3 digits
- Overload Protection: 600V DC or AC rms

Continuity and Diode Test:
- Continuity: Audible indication with a response time of approx. 500ms
- Diode Test: Test current of 0.8mA with an accuracy of 1.5% + 5 digits
- Overload Protection: 600V DC or AC rms

General Features:
- Display: 4000 count LCD, updates 2/sec
- Power: 9V battery, with auto power off after 10 minutes
- Dimensions and Weight: CM82 - 279 x 103 x 53mm, 515g; CM84 - 281 x 108 x 53mm, 570g
- Includes carrying case, test leads, and battery

Environmental and Safety:
- Operating Temperature: 0°C to 50°C
- Storage Temperature: -20°C to 60°C
- Altitude: Up to 2000m
- Safety Standards: Conforms to BS EN 61010-1 & 61010-2-032, CAT IV 600V, CAT III 1000V
- EMC: Conforms to BS EN 61326-1

Test Leads (TL16):
- Maximum Voltage: 1000V AC/DC
- Maximum Current: 10A continuous
- Safety: Conforms to BS EN 61010-031

Additional Products:
Martindale offers a range of other testing equipment including 17th Edition Testers, Calibration Equipment, and more.
See more

Catalog excerpts

CM82/CM84-1

Input impedance Overload Protection: 1000V DC or 750V AC rms AC Current Range All specied accuracies are at 23°C ± 5°C, <70% RH for 1 year Temperature Coefcient: 0.1 x (specied accuracy) per °C (0°C to 18°C, 28°C to 50°C) Input impedance All accuracies below are expressed as ± (percentage of reading + digits) * CM82 only Overload Protection: 1000A AC rms DC Current (CM 84 only) Range Resistance Range Open circuit voltage Sensitivity (10Hz to 1 MHz): >3.5V AC rms Minimum input frequency: 10Hz Minimum pulse width: >1μs Duty cycle limits: >30% and <70% Overload protection: 600V DC or AC rms Response time Open circuit voltage Test current Open circuit voltage Audible indication

 Open the catalog to page 1
CM82/CM84-2

CM82/CM84 GENERAL Display: Liquid crystal display Digital, 4000 counts, updates 2/sec Polarity: automatic, positive implied, ‘-‘ for negative polarity indication Overrange: (OL) or (-OL) is displayed Power: 9V, PP3 carbon-zinc battery (IEC 6F22, NEDA 1604D) Battery life: 150 hours (CM82), 75 hours (CM84), typical with carbon zinc symbol displayed Low battery indication: Auto power off: after 10 minutes Jaw opening capability: conductor diameter 51mm (CM82), 57mm (CM84) bus bar: 70 x 18mm Dimensions: 279 x 103 x 53mm (CM82), 281 x 108 x 53mm (CM84) Weight: approx. 515g (CM82), 570g (CM84), including...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.