Specification CM76 AC/DC Clamp Meter Specification CM76 AC/DC Clamp Meter Measurement range: 10Hz to 10kHz Input sensitivity: ≥ 0.2V AC rms Input Impedance: 10MΩ Maximum input voltage: 600V AC rms ELECTRICAL SPECIFICATIONS All specified accuracies are at 23°C ± 5°C, <75% RH for 1 year. Temperature coefficient: <0.1 x (specified accuracy) per °C. (0°C to 18°C, 28°C to 40°C) Frequency measurement using Hz/Duty ranges AC conversion: Average responding Maximum input voltage: 400A DC Current Range Input voltage range: 200mV to 10V AC rms Overload protection: 250V DC or AC rms Duty Cycle Duty cycle accuracy: ± 3.0% Resolution: 0.1% Measurement range: 0.1% to 99.9% Duty cycle measurement using AC current ranges Frequency response: 10Hz to 1kHz Input sensitivity: ≥ 4A AC rms Maximum input current: 400A AC rms AC conversion: Average responding Duty cycle measurement using AC voltage ranges Frequency response: 10Hz to 10kHz Specification CM76 AC/DC Clamp Meter Specification CM76 AC/DC Clamp Meter Maximum input voltage: 750V AC rms Input Impedance: 10MΩ Overload Protection: 1000V DC or 750V AC rms Input sensitivity: ≥ 1V AC rms Input Impedance: 10MΩ Maximum input voltage: 750V AC rms Duty cycle measurement using Hz/Duty ranges Frequency response: 1Hz to 10MHz Input voltage range: 200mV to 10V AC rms Overload protection: 250V DC or AC rms Maximum input voltage: 1000V DC Input Impedance: 10MΩ Overload protection: 1000V DC or 750V AC rms Frequency Frequency measurement using AC current ranges Range Measurement range: 10Hz to 1kHz Input sensitivity: ≥ 4A AC rms Maximum input current: 400A AC rms Open circuit voltage: 0.4V Overload Protection: 250V DC or AC rms Capacitance Range Frequency measurement using AC voltage ranges Range
Open the catalog to page 1Specification CM76 AC/DC Clamp Meter Continuity Resolution: 0.1Ω Audible indication: <40Ω Open circuit voltage: ~1.2V Overload protection: 250V DC or AC rms Diode Test Resolution: 0.001V Forward DC test current: ~ 1mA Reversed DC test voltage: ~ 3.3V Overload protection: 250V DC or AC rms GENERAL Display: Liquid crystal display with a maximum reading of 4000 digits and analog bargraph. Polarity: Automatic, positive implied, ‘-‘ for negative polarity indication. Overrange: (OL) or (-OL) is displayed Low battery indication: symbol is displayed when the battery voltage drops to ≤ 3.7V Sampling rate:...
Open the catalog to page 21 Page
2 Pages
1 Page
36 Pages
4 Pages
1 Page
3 Pages
1 Page
1 Page
1 Page
3 Pages
1 Page
35 Pages
1 Page
6 Pages
1 Page
1 Page
1 Page