Specification Overview
The CM100 Flexible Current Meter is designed for accurate electrical measurements under specified conditions. All accuracies are guaranteed at 23°C ± 5°C with less than 80% relative humidity for one year. The temperature coefficient is 0.1 times the specified accuracy per degree Celsius within the range of 0°C to 18°C and 28°C to 40°C.
Electrical Specifications
  • Range and Accuracy: The meter offers three ranges: 30 A with 0.01 A resolution, 300 A with 0.1 A resolution, and 3000 A with 1 A resolution. The accuracy is ± (3.0% of reading + 5 digits) for frequencies between 45 Hz and 500 Hz.
  • AC Conversion: Utilizes true RMS conversion, with accuracy specified from 2% to 100% of the range.
  • Crest Factor: Up to 1.6 at full scale and 3.2 at half scale.
  • Position Sensitivity: Measurement accuracy assumes a centrally positioned conductor. Errors increase with distance from the loop center, as detailed in the position sensitivity error table.
Environmental Conditions
  • Operating Environment: 0°C to 50°C, less than 80% RH, non-condensing.
  • Storage Temperature: -10°C to 60°C, 70% RH.
  • Altitude: Suitable for use up to 2000 meters.
General Features
  • Display: Liquid crystal display with a maximum reading of 3150 digits. Displays "–OL–" for overrange and a low battery symbol when necessary.
  • Sampling Rate: 2 times per second.
  • Auto Power Off: Activates after approximately 15 minutes of inactivity.
  • Power Supply: Operates on 2 x 1.5 V AAA batteries, with a typical battery life of 120 hours using alkaline batteries.
  • Dimensions and Weight: The meter measures 120mm x 70mm x 26mm and weighs approximately 286g including batteries. Probe cable lengths are 457mm for CM100/18 and 1524mm for CM100/60, with a nominal diameter of 8.5mm.
  • Included Accessories: Comes with 2 x 1.5V AAA batteries and instructions.
See more

Catalog excerpts

Clamp Meters: Martindale CM100-1

SpeciÀcation CM100 Flexible Current Meter Note 1: Measurement accuracy assumes a centrally positioned conductor, no external electrical or magnetic eld and within operating temperature range. See gure 2 and the position sensitivity error table below for additional errors where the conductor is not centrally positioned. Position from loop centre (refer to gure 2) A AC conversion: True rms. True rms AC current accuracy is specied from 2 % of range to 100 % of range. Crest factor: d 1.6 at full scale (30.00A/300.0A/3000A). d 3.2 at half scale (15.00A/150.0A/1500A). ELECTRICAL All specied accuracies are at 23°C ± 5°C, <80% RH for 1 year. Temperature Coefcient: 0.1 x (specied accuracy) per °C. (0°C to 18°C, 28°C to 40°C). ENVIRONMENTAL Operating environment: 0°C to 50°C, <80% RH, non-condensing Storage temperature: -10°C to 60°C, 70% RH Altitude: Up to 2000m GENERAL Display: Liquid crystal display with a maximum reading of 3150 digits. Overrange: “–OL–” is displayed Low battery indication: symbol is displayed when the battery voltage drops below the operational level Sampling rate: 2 times per second. Auto power off: After approx. 15 minutes Power: 2 x 1.5 V AAA batteries (IEC LR03, NEDA 24A) Battery life: 120 hours typical with alkaline Dimensions: Meter: 120mm (L) x 70mm (W) x 26mm (D) Probe cable length: 457mm (CM100/18), 1524mm (CM100/60) Probe cable diameter: 8.5mm nominal Cable length (probe to meter): 1.8m Weight: 286g approx. including batteries Includes: 2 x 1.5V AAA batteries and instructions

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.