Electrical Specifications
  • Transmitter: The output carrier signal frequency is 125 kHz. The voltmeter function ranges from 12V to 400V DC & AC rms (50Hz to 60Hz) with an accuracy of ± 2.5%. The maximum input voltage is 400V DC or AC rms.
  • Receiver: The tracking depth varies by mode: Single pole at approximately 2m, Dual pole at approximately 0.5m, Single loop line at approximately 2.5m, and UAC at approximately 0.4m.
General Specifications
  • Temperature & Humidity: Operating conditions are 0°C to 40°C with a maximum of 80% relative humidity (non-condensing). Storage conditions are -20°C to 60°C with the same humidity constraints. The altitude limit is up to 2000m.
  • Power: The transmitter uses a single 9V IEC 6LR61 battery, while the receiver uses 6 x 1.5V AAA, IEC LR03 batteries. Current consumption for the transmitter is approximately 31mA minimum and 115mA maximum, and for the receiver, it is approximately 32mA minimum and 89mA maximum. The receiver has an auto-off time of approximately 10 minutes.
  • Dimensions & Weight: The transmitter measures 190 x 89 x 42.5mm and weighs approximately 360g without batteries and 420g with batteries. The receiver measures 241.5 x 78 x 38.5mm and weighs approximately 280g without batteries and 350g with batteries.
  • Includes: The package includes a bag, TL47 test leads with crocodile clips, an earthing rod, a 9V alkaline battery, 1.5V alkaline batteries x 6, and instructions.
Safety
  • Transmitter: Conforms to BS EN61010-1 CAT III 300V, Class II Double Insulation, Pollution degree 2.
  • Receiver: Conforms to BS EN 61010-1 CAT III 600V, Class II Double Insulation, Pollution degree 2.
  • Test Leads: Supplied test leads conform to BS EN61010-031 CAT III 1000V, 10A.
  • EMC: Conforms to BS EN61326.
See more

Catalog excerpts

CD1000-1

SpeciÀcation CD1000 Cable Detector SpeciÀcation CD1000 Cable Detector Power Transmitter: single 9V IEC 6LR61 battery Receiver: 6 x 1.5V AAA, IEC LR03 batteries Current consumption Transmitter: 31mA approx minimum 115mA approx maximum Receiver: 32mA approx minimum 89mA approx maximum Auto off time: 10 minutes approx (receiver only) Dimensions Transmitter: 190 x 89 x 42.5mm Receiver: 241.5 x 78 x 38.5mm ELECTRICAL SPECIFICATIONS Transmitter: Output carrier signal frequency: 125 kHz Voltmeter function: Range: 12V to 400V DC & AC rms (50Hz to 60Hz) Accuracy: ± 2.5% Maximum input voltage 400V DC or AC rms Receiver: Tracking Depth Weight Transmitter: 360g approx (batteries not included) 420g approx (batteries included) Receiver: 280g approx (batteries not included) 350g approx (batteries included) Includes: bag, TL47 test leads (with crocodile clips), earthing rod, 9V alkaline battery, 1.5V alkaline battery x 6 and instructions. Cable locating mode Maximum tracking depth Single pole Dual pole Single loop line GENERAL SPECIFICATIONS Temperature & Humidity Operating: 0°C to40°C max 80% R.H. (non condensing) Storage: -20°C to 60°C max 80% R.H. (non condensing) Altitude: up to 2000m Transmitter: Conforms to BS EN61010-1 CAT III 300V Class II Double Insulation Pollution degree: 2 Receiver: Conforms to BS EN 61010-1 CAT III 600V Class II Double Insulation Pollution degree: 2 Test leads supplied conform to BS EN61010-031 CAT III 1000V, 10A EMC: Conforms to BS EN61326