Laboratory Freeze Dryers Routine Applications - 1

Laboratory freeze drying systems Routine applications Reliable and versatile – LSCbasic

Open the catalog to page 1
Laboratory Freeze Dryers Routine Applications - 2

Process reliability and versatility For your application Experience, expertise and versatility for your freeze drying Benefit from our experience as a leading manufacturer of freeze drying systems for more than 75 years. We offer you a closely graduated series of systems for product-specific freeze drying with a wide range of optimization options. The highly diverse, modularly structured range of accessories allows the laboratory freeze drying systems to be used for a wide variety of tasks. Assured results in daily routine use Routing operations in particular make high demands on system...

Open the catalog to page 2
Laboratory Freeze Dryers Routine Applications - 3

Graduated condenser temperatures and drying capacities Our product line for daily routine applications Laboratory freeze drying systems are available in various sizes with a wide range of accessories. Product designation format Alpha 1-4 LSCbasic "T L System type Controller type Ice capacity Temperature level Different ice condenser temperatures are available for each base model, depending on the solvents used: Temperature level Temperature Typical application area 2 -85 °C Products with low freezing points 3 -105 °C Products containing solvents Alpha 1-2 LSCbasic Alpha 1-4 LSCbasic Alpha...

Open the catalog to page 3
Laboratory Freeze Dryers Routine Applications - 4

New EntryPackage at a special priceYour start into efficient lyophilisation with our EntryPackage The Alpha 1-2 LSCbasic with high quality equipment is a universal tool for your successful processes, day after day. Innovative technology for outstanding results • Small, high-performance benchtop unit • Drying chamber above the ice condenser chamber for high sublimation performance and short process times • Ice condenser chamber with internal condenser coils, entirely made of high-grade stainless steel • Display of ice condenser temperature and vacuum, indirect product temperature...

Open the catalog to page 4
Laboratory Freeze Dryers Routine Applications - 5

Example configurations Wide range means numerous possibilities 1) For round-bottom flasks, wide-mouth filter bottles or ampoule distributors 2) Sealing device Typical applications • Excrement • Plant material for DNA analysis • Colloids from cider or wine • Content analytics For round-bottom flasks, wide-mouth filter bottles or ampoule distributors Sealing device

Open the catalog to page 5
Laboratory Freeze Dryers Routine Applications - 6

Intuitive touchscreen user interface Quick and easy front loading LSCbasic system controller LyoCube acrylic glass Cutting-edge technologies are brought together in the LSCbasic system controller to make an easy-to-use, intuitive user interface. Automatic process sequences ensure reproducible results. Front loader for extremely simple operation with large capacity LyoCube is the ideal solution when fast and convenient loading is a primary consideration or bulky products have to be freeze dried. • Manual or automatic process continuation • It is compatible with every Martin Christ laboratory...

Open the catalog to page 6
Laboratory Freeze Dryers Routine Applications - 7

Specialized system for organic solvents Two system configurations For more information about Alpha 3-4 LSCbasic, see the webpage: Freeze drying is not only used for water-based materials. Typical examples include HPLC fractions with organic or inorganic solvents, such as acetonitrile, TFA and other alcohols, or other products with t-butanol, DMSO, etc. The Alpha 3-4 LSCbasic is available in two defined packages, fully aligned to the requirements of freeze drying with solvents. Increased safety considerations require special system configurations: • Safe: No sources of ignition, such as...

Open the catalog to page 7
Laboratory Freeze Dryers Routine Applications - 8

Technical data Our product range Technical data Ice condenser • Max. capacity • Temperature • Chamber volume approx. -55 °C approx. -55 °C approx. -85 °C approx. -55 °C approx. -85 °C approx. 3.5 l approx. 6.5 l approx. 6.5 l approx. 11 l approx. 11 l With a unique and broad graduated range of devices and accessories, we can supply freeze drying systems and vacuum concentrators for every application. Let us show what we can do! approx. 28 kg approx. 42 kg approx. 55 kg approx. 63 kg approx. 78 kg approx. 80 kg Electrical connection (other variants available upon request) Noise level as per...

Open the catalog to page 8
Laboratory Freeze Dryers Routine Applications - 9

Martin Christ Gefriertrocknungsanlagen GmbH An der Unteren Sose 50 37520 Osterode am Harz info@martinchrist.de www.martinchrist.de