Marsh Bellofram Diversified Electronics Division SLU-100 Series Universal Phase Monitor
1Pages

{{requestButtons}}

Catalog excerpts

Marsh Bellofram Diversified Electronics Division SLU-100 Series Universal Phase Monitor - 1

SLU-100 Series Diversified Electronics atcdiversified.com 800.727.5646 208 Phase Voltage Monitors // SLU-100 Series Phase Monitor Relays (3-Phase Monitors) provide cost-effective protection against premature equipment failure caused by voltage faults on 3-Phase systems (Wye or Delta). The SLU Series multi-mode phase monitoring relay, was designed for the convenience of electrician's, maintenance managers and engineers. A single SLU Phase Monitoring Relay can be easily adjusted for the voltage, imbalance percentage and time delay requirements to protect against unbalanced voltages or single phasing regardless of any regenerative voltages. Both Delta and Wye systems may be monitored. In Wye systems, connections to neutral are NOT required. NOTE: Not recommended for generator or variable frequency drive applications. Call technical support for application assistance. U n i v e r s a l P h a s e Mo n i t o r \\\SPECIFICATIONS AUTO RANGING SCALES Frequency Nominal Line-to- Line Voltages Adjustable Range 60Hz 208, 220, 240 200-250 380, 415, 440, 460, 480 360-500 50Hz 208, 220, 240 200-250 346, 380, 415 330-430 VOLTAGE BAND Drop-out ±10% of Range Setting (Under/Over) Pick-up ±7% of Range Setting (Under/Over) MAXIMUM VOLTAGE 550 VAC (Line-to-Line) PHASE SEQUENCE ABC (Will Not Operate On CBA Sequence) POWER REQUIRED 90VA Max. PHASE UNBALANCE 2% to 10%, Adjustable Drop-out Hysteresis 10% of Setting PHASE SHIFT 13° Drop-out, 12° Pick-up (Ø-Loss) FREQUENCY SHIFT 50/60 Hz Drop-out ± 4% Pick up ± 3% RESET Automatic or Manual Mode RELAY OUTPUT SPDT, 10A @ 240VAC Resistive, 1/2 HP @240VAC INDICATORS Flashing Continuous Normal (Green LED) Fault Delay Active Relay Energized Fault (Red LED) Restart Delay Active Relay De-energized RESPONSE TIMES Power Up 2.5 S Minimum Fault Delay 0.1 to 25 S, Adjustable Severe Fault 100mS (Phase-Loss, Unbalance or Phase Reversal) Restart 0.5 to 300 S, Adjustable (Auto Reset) TEMPERATURE RATINGS Operate 32° to 131°F (0° to +55°C) Storage -49° to 185°F (-45° to +85°C) REPEAT ACCURACY 1% @ Fixed Condition TERMINALS (DIN) Slotted Screw Terminal Clamps, 12AWG Max. ENCLOSURE Style “A” LEXAN® Dust Cover DIN 35mm DIN Rail, 14 Term Polycarbonate Housing WEIGHT 0.35 to 0.5 lbs. \\\TOP LABELS Plug-In DIN Rail DIN Rail \\\DIMENSIONS (INCHES) SLU-100-ASA SLU-100-ASD \\\ORDERING INFORMATION MODEL NUMBER DESCRIPTION SLU-100-ASA Universal Phase Monitor SLU-100-ASD Din Rail Mount Universal Phase Monitor

Open the catalog to page 1

All Marsh Bellofram catalogs and technical brochures

  1. 5204

    1 Pages

  2. P95H Regulator

    15 Pages

  3. Marsh Catalog

    84 Pages

Archived catalogs