Product catalog summary
Overview: The ASC-500 Series by Diversified Electronics provides short cycle protection for compressors by locking them out for a set period after a voltage or thermostat interruption. This prevents the delay period from increasing with subsequent interruptions and ensures that temperature control remains unaffected. The typical compressor off time exceeds five minutes, so these timers do not extend the off cycle under normal conditions.
Features: These are two-terminal Short Cycle Timers that are easy to install and connect in series with the control voltage and relay. The 24 VAC model includes a built-in bypass circuit for continuous flow through the thermostat's cooling anticipator when the timer output is off.
Ordering Information: The series includes three models: ASC-500-5, ASC-501-5, and ASC-502-5, all of which are Delay-On-Break Timers.
Specifications:
  • Control Voltage: ASC-500-5 operates at 24 VAC, ASC-501-5 at 110/120 VAC, and ASC-502-5 at 208/240 VAC.
  • Output Rating: ASC-500-5 has an inrush of 250 VA and a run of 25 VA at 24 VAC. ASC-501-5 and ASC-502-5 both have an inrush of 1250 VA and a run of 125 VA at their respective voltages.
  • Time Delay: 5 minutes with a tolerance of ±20%.
  • Dimensions: 2.0" x 2.0" x 0.75" high.
  • Weight: 3 oz.
See more

Catalog excerpts

Marsh Bellofram Diversified Electronics Division ASC-500 Series HVAC Delay-on-Break Timer -1

ASC-500 Series Diversified Electronics atcdiversified.com 800.727.5646 268HVAC Controls // ASC-500 Series This family of controls provides short cycle protection by locking out the compressor for a period of time after a voltage or thermostat interruption. Subsequent interruptions will not increase the delay period. Since the delay begins when the interruption occurs, the temperature control is not affected. Under normal operating conditions, the compressor off time is longer than five (5) minutes. In this case, the use of these timers will not lengthen this off cycle. These are easy to install two (2) terminal Short Cycle Timers that connect in series with the control voltage and control relay. The 24 VAC model employs a built-in bypass circuit for allowing continuous flow through the thermostat’s cooling anticipator while the timer output is off. D e l a y - O n - B r ea k T ime r \\\ORDERING INFORMATION MODEL NUMBER DESCRIPTION ASC-500-5 Delay-On-Break Timer ASC-501-5 Delay-On-Break Timer ASC-502-5 Delay-On-Break Timer \\\SPECIFICATIONS CONTROL VOLTAGE ASC-500-5 24 VAC ASC-501-5 110/120 VAC ASC-502-5 208/240 VAC OUTPUT RATING ASC-500-5 250 VA Inrush; 25 VA Run @ 24 VAC ASC-501-5 1250 VA Inrush; 125 VA Run @ 120 VAC ASC-502-5 1250 VA Inrush; 125 VA Run @ 240 VAC TIME DELAY 5 min. ±20% DIMENSIONS 2.0" x 2.0" x .75" high WEIGHT 3 oz. \\\WIRING

 Open the catalog to page 1

All Marsh Bellofram catalogs and technical brochures

  1. 5204

    1  Page

  2. P95H Regulator

    15  Pages

  3. Marsh Catalog

    84  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.