800.727.5646 automatictiming.com Automatic Timing & Controls 366B Series Predetermining Counters // 366B Series 131 Based on a powerful built-in microcomputer, the compact 366B is the most versatile and cost-effective counter ATC has ever built. No industrial counter has ever achieved a higher level of reliability and ruggedness than the 366B. It has no moving parts in its electronic logic circuits, only plug-in circuit boards which are computer-tested for reliability and assembled virtually without hand wiring. Its few mechanical components have been selected for reliable service; long life relays with heavy-duty contacts and rotary set point selector switches with extremely low wear characteristics. CONTACT BOUNCE AND NOISE IMMUNITY: No industrial counter offers greater immunity to noise and contact bounce than the 366B. Most noise encountered in typical industrial environments is blocked by such design features as full-wave bridges and a transformer power supply... so effectively that the 366B does not have to be shielded. Furthermore the 366B’s microcomputer employs redundant sampling logic to detect and reject any noise pulse that manages to penetrate its defenses. Through the same powerful technique, the microcomputer also detects and rejects even severe contact bounce. As a result, the 366B maintains absolute count accuracy and is virtually immune to false starts and reset, even in difficult industrial environments. COMPUTATION: Through its internal microcomputer, the 366B keeps track of the set point throughout the count cycle. Whenever there is a change in set point, even during a cycle, it instantly recomputes the remaining count and accurately determines the number of counts before count-out. This unique capability is especially valuable in the count-down modes as it allows you to shorten or lengthen a cycle without loss of accuracy. PROGRAMMABLE DISPLAY: The 366B’s three-digit cycle progress display will count UP to or DOWN from the set point, depending on the position of an internal jumper. After count-out, the display will either STOP or GO. In the UP & GO program, the display counts up to the set point and continues to count after count-out; in the DOWN & GO mode, it counts down to the set point, then begins to count up (from zero) after count-out. WIDE RANGE: Each 366B Long-Ranger covers the overall span of 1 to 99,900 counts in three switch-selected ranges of 1 to 999, 10 to 9990 or 100 to 99,900. It can be optimized within any selected range simply by removing appropriate selector knobs (e.g. with the counter in the 1 to 999 range, you can obtain a tamper-proof span of 1 to 99 by setting the left selector at 0 and removing the knob.) To the right of the three-digit display, a counting bar ( ) blinks on each time a pulse is received. At left, a marker turns on when the delayed relay is energized at count-out. SELF-DIAGNOSTICS: A built-in diagnostic program lets you verify- -without using any test instrument--that the counter’s functional circuits are operating properly. Just follow the instructions on the flip-up card, using the counter’s own display for the test readout. If all self-test displays are correct, any malfunction is almost certainly due to external circuits or to the relays, not the counter. COMPACT, PLUG-IN AND DUST-TIGHT: Packaged in a 72mm2 DIN housing, the 366B occupies 40% less panel space than most other industrial counters. It is a true plug-in counter that can be replaced in seconds without disturbing housing or wiring. The 366B is also fully gasketed and O ring sealed to be dust and water-tight whether panel or surface-mounted. POSITIVE RESET TIME AND PULSE LENGTH: Digitally clocked by the microcomputer, the 366B’s reset time is consistently of the same duration, regardless of variations in line voltage, power supply or cycle length. When the 366B operates in repeat-cycle mode, the output pulse is also digitally clocked so that both the time of occurrence and its duration are consistent from cycle to cycle. Long- R a n ge r C omp u t i n g C o u n t er TERMINAL WIRING: INDICATING MODEL \\\DIMENSIONS (INCHES/MILLIMETERS) \\\WIRING
Open the catalog to page 1MODEL NUMBER >>>>>> 366B P X Range 400 Q 30 P X 1-999, 10-9990 or 100-99900 (switch selected) Special 000 Voltage & Frequency 120, 50/60 Hz 240, 50/60 Hz R 24 VAC, 50 or 60 Hz T 24 VDC N Special K Arrangement Selectable Count Up or Count Down with Display Selectable Count Up & Go or Count Down & Go with Display 50 Features Basic plug-in unit Standard unit ACCESSORIES – 0353-260-27-00: Surface mounting bracket kit 0305-265-61-70: Retrofit kit 366B Series Automatic Timing & Controls automatictiming.com 800.727.5646 132 Predetermining Counters // 366B Series As soon as power is applied to...
Open the catalog to page 2800.727.5646 automatictiming.com Automatic Timing & Controls 366B Series Predetermining Counters // 366B Series 133 \\\SPECIFICATIONS MODELS Display model only for operation at 120, 240 or 24 VAC; and 24 VDC. Unit counts on break (i.e. when count input switch opens). Unit operates in on delay mode only. RANGE Switch-selectable ranges of 1 to 999, 10 to 9990, and 100 to 99900. REPEAT ACCURACY 100% (+0 count on all ranges) RESET TIME Clocked at 40 mSEC COUNT INPUT CHARACTERISTICS AC Max. count rate 1000/MIN (symmetrical input) Min. pulse on time 20 mSEC Min. pulse off time 30 mSEC DC Max....
Open the catalog to page 3All Marsh Bellofram catalogs and technical brochures
-
Full Catalog BelGAS
307 Pages
-
5204
1 Pages
-
P627 High Flow Gas Regulator
10 Pages
-
P212 Pressure Regulator
16 Pages
-
P200 Pressure Regulator
19 Pages
-
P95H Regulator
15 Pages
-
P99 Pressure Reducing Regulator
11 Pages
-
P133 Pressure Regulator
12 Pages
-
P140 Pressure Regulator
4 Pages
-
P303 Pressure Regulator
11 Pages
-
P300 Pressure Regulator
11 Pages
-
P203 Pressure Reducing Regulator
18 Pages
-
F300 Pressure Regulator
7 Pages
-
P600 Pressure Regulator
7 Pages
-
P289RC Exhaust Booster
2 Pages
-
W627 Liquid Gas Regulator
8 Pages
-
F627 High Flow Gas Regulator
7 Pages
-
BELLOFOAM™ 7804
1 Pages
-
BELLOFOAM™ 7704
1 Pages
-
BELLOFOAM™ 7604
1 Pages
-
Marsh Catalog
84 Pages
-
P79 Air Relays
4 Pages
-
Automated Timing & Controls
142 Pages
-
Motor Protection
86 Pages
-
Digital Controllers
30 Pages
-
P630 High Flow Gas Regulator
12 Pages
-
P39 Standard Gas Regulators
4 Pages
-
P40 & P40 NACE Regulators
2 Pages
-
P912 Pressure Regulator
2 Pages
-
P119 Control Valve
4 Pages
-
BelGAS Product Overview LT5040
12 Pages
-
KING-GAGE Product Catalog
12 Pages
-
BelGas P200 Pressure Regulator
18 Pages