Effective: December, 2009 Supplment 1200-30 Inventory Monitoring Process Intgration Downpipe Backflow Check Valve This engineered component will help you prevent siphoning or backflow of liquid through a downpipe installed in tank level gauging applications. Typically such level measurement employs a continuous air flow to clear the downpipe of liquid with the resulting backpressure equal to the hydrostatic head (depth). However, in the event the air supply is turned off, the loss of air pressure may allow liquid to flow back up the downpipe. This is especially true when the downpipe may be installed through the side of the tank below the point of the tank's maximum depth. With the KING-GAGE Downpipe Backflow Check Valve, you can guard against liquid traveling up through the downpipe and into the system pressure lines. It utilizes a specially designed float pin that rises up to seal the valve shut when liquid enters from the downpipe through the bottom of the unit. The advantage of a float check is that it doesn't create a pressure drop that would affect the level gauge reading. (Spring-loaded check valves can impact the accuracy of a downpipe or bubbler system if installed at the tank entry point.) This check valve is not intended to substitute for a shut off or isolation valve for the downpipe into the tank. Not recommended for use with heavy diesel fuel oil or other high viscosity liquids. Model 6563 Check Valve Air Flow No Air Flow Float Sealed Of course, proper placement and installation is important for reliable operation of the Downpipe Check Valve. It is recommended that you install the check valve in an upright position on a vertical portion of the downpipe so that the float will move freely. Do not position the check valve along any horizontal run of the downpipe as it will fail to operate as intended. Float Open Downpipe Air Flow ^KINC-C/tCi KINGENGINEERING DIVISION www.king-gage.com
Open the catalog to page 1KING-GAGE® Downpipe Backflow Check Valve Supplשment 1200-30 The Model 6563 Downpipe Check Valve is well suited for use on downpipe systems employing KING-GAGE Purge Control or LiquiSeal Purge Control liquid level transmitters. Hydrostatic pressure measurement using a downpipe (also known as a bubbler system) is a proven tank gauging technique that is both accurate and reliable. EXTERNAL INSTALLATION Recommended installation of the Downpipe Check Valve is at the top of the downpipe as it exits the tank. (Depending upon the type of tank application and purge control used, this exit may be...
Open the catalog to page 2All Marsh Bellofram catalogs and technical brochures
-
Full Catalog BelGAS
307 Pages
-
5204
1 Pages
-
P627 High Flow Gas Regulator
10 Pages
-
P212 Pressure Regulator
16 Pages
-
P200 Pressure Regulator
19 Pages
-
P95H Regulator
15 Pages
-
P99 Pressure Reducing Regulator
11 Pages
-
P133 Pressure Regulator
12 Pages
-
P140 Pressure Regulator
4 Pages
-
P303 Pressure Regulator
11 Pages
-
P300 Pressure Regulator
11 Pages
-
P203 Pressure Reducing Regulator
18 Pages
-
F300 Pressure Regulator
7 Pages
-
P600 Pressure Regulator
7 Pages
-
P289RC Exhaust Booster
2 Pages
-
W627 Liquid Gas Regulator
8 Pages
-
F627 High Flow Gas Regulator
7 Pages
-
BELLOFOAM™ 7804
1 Pages
-
BELLOFOAM™ 7704
1 Pages
-
BELLOFOAM™ 7604
1 Pages
-
Marsh Catalog
84 Pages
-
P79 Air Relays
4 Pages
-
Automated Timing & Controls
142 Pages
-
Motor Protection
86 Pages
-
Digital Controllers
30 Pages
-
P630 High Flow Gas Regulator
12 Pages
-
P39 Standard Gas Regulators
4 Pages
-
P40 & P40 NACE Regulators
2 Pages
-
P912 Pressure Regulator
2 Pages
-
P119 Control Valve
4 Pages
-
BelGAS Product Overview LT5040
12 Pages
-
KING-GAGE Product Catalog
12 Pages
-
BelGas P200 Pressure Regulator
18 Pages