KING-GAGE® Model 5880 Multi-Point Single-Channel Set Point Control

KING-GAGE® Model 5880 Multi-Point Single-Channel Set Point Control

KING-GAGE® Model 5880 Multi-Point Single-Channel Set Point Control

Product catalog summary
Overview: The Multi-Point Process Switch is a single-channel analog set-point control device designed for continuous monitoring of process loops. It features four adjustable set-points and is compatible with process transmitters that have a 4-20 mA output.
Specifications:
  • Power Requirements: 115 Vac/60 Hz, 3.45 Watt/0.03 Amp, fused at 0.1 Amp.
  • Temperature Range: Operating: 32°F to 158°F (0°C to 70°C); Storage: -40°F to 158°F (-40°C to 70°C).
  • Input: 4-20 mA dc current with a 132 Ohm input impedance.
  • Output: Four independent SPDT relays, rated at 3.0 Amps @ 115 Vac or 24 Vdc.
  • Dimensions: 7-1/8" (H) x 2" (W) x 6" (D); Weight: 22 oz (624 g).
Key Features:
  • Adjustable Set Points: Four user-adjustable set-points with LED status indicators for visual confirmation.
  • SPDT Relay Output: Each set-point has an independent relay that energizes when the milliamp value is exceeded.
  • Adjustable Deadband Range: A single deadband potentiometer controls all set-points, adjustable from 1.0% to 12.5% FS.
  • Automatic Overload Reset: Features a PTC resistor circuit for protection against input circuit overloads, automatically resetting when current levels drop.
Applications: Suitable for controlling continuous process operations, providing fail-safe limiting, or alarm functions. It can be used in various industrial control environments to monitor process variables such as level, pressure, or temperature.
Diagram and Wiring: The device must be wired in series with the transmitter to maintain proper polarity. It includes a diagram illustrating the typical process loop setup.
See more

Catalog excerpts

KING-GAGE® Model 5880 Multi-Point Single-Channel Set Point Control-1

Effective: March, 1997 (replaces October, 1995) Supplment 1400-10 mg\e Channel Analog Set-Pomt Contro ■ 4 Adjustable Set Points ■ Simple Control Process Functions ■ Independent SPDT (Form C) Relays ■ For Process Transmitters with 4-20 mA Output Multi-Point Process Switch is a single channel analog set-point control. It provides continuous monitoring of a typical process loop with four (4) independent set-points that are user adjustable over the full range. The process Switch may be used in conjunction with any process transmitter (i.e., pressure, level, temperature) that incorporates a two-wire, 4-20 mA output. SPDT Relay Output Control output relays are included for each set-point. During operation, the relay is energized once the mil-liamp value is exceeded. Both normally-open (N.O.) and normally-closed (N.C.) contacts are provided with the Form-C type relays. These SPDT relays are rated 3.0 Amps @ 115 Vac. Adjustable Deadband Range An integral deadband is selectable for the set-point values offering up to 12.5 % F.S. adjustability. This dead-band is adjustable for the set-points as a group (i.e., not independently adjustable for each set-point). The Multi-Point Process Switch is factory preset with a nominal 1% F.S. deadband. Automatic Overload Reset This unit features protection against input circuit over-loads and automatically resets when current level drops. Using advanced PTC resistor technology, the protection circuit trips whenever the signal input current exceeds 70 mAdc. Model 5880-1 Process Switch KING-GAGE ^^BaiTlNG engineering division www.king-gage.com

 Open the catalog to page 1
KING-GAGE® Model 5880 Multi-Point Single-Channel Set Point Control-2

Multi-Point Process Switch Supplement 1400-10 Process Applications 4-20 mA Input Signal The Process Switch can be used to control continuous process operations, provide fail-safe limiting or alarm functions. In a level application, the switch can be used to actuate pumps, outlet valves or even to initiate CIP cycles. The Multi-Point Process Switch can monitor process variables within any industrial control environment. MULTI-POINT Process Switch offers greater accuracy than conventional alarm trips. Monitors and triggers simple process functions more easily as compared to PID controllers, PLCs...

 Open the catalog to page 2
KING-GAGE® Model 5880 Multi-Point Single-Channel Set Point Control-3

Multi-Point Process Switch Supplment 1400-10 Dimensions Spcifications Front View Top View Power Requirements Nominal 115 Vac./60 Hz. (unregulated) 3.45 Watt/0.03 Amp - fused @ 0.1 Amp Temperature Range (Environmental) 32° F to 158° F/0° C to 70° C - op-erating (-40° F to 158° F/-40° C to 70° C -storage) Input dc current: 4-20 mA Current Limiting (Overload) 70 mAdc maximum; automatic trip/ reset using PTC resistor (positive temperature coefficient) circuit Input Impedance 132 Ohm resistance (3 Vdc drop @ 20 mAdc) Set-Points (4) four independent user set-points; continuously adjustable over full...

 Open the catalog to page 3
KING-GAGE® Model 5880 Multi-Point Single-Channel Set Point Control-4

User Set-Points LED Status Indicators Adjustable Set-Points The Process Switch has four (4) user set-points that can be adjusted to control continuous process operations, provide fail-safe limiting or alarm functions. Front Panel - LED Status Indicators are located on the front panel of the Process Switch. Each of the four (4) LEDs correspond to "SET1, SET2, SET3, SET4" adjust-ments and output relays. When illuminated, "rie LED indicates that the set-point has been reached and corresponding relay energized. Not Energized c O Four (4) independent SPDT (single-pole/double-throw) relays are provided...

 Open the catalog to page 4