Effective: August, 2011 Supplment 1100-34 KING-GAGE Tank Liquid Lev Inventory Monitoring Process Intgr驢t! ES2 Slimline Transmitter Robust protection in washdown environments Continuous liquid level measurement Two Wire Loop Powered (4-20 mA) KING-GAGE ES2 transmitters provide liquid level measurement for inventory monitoring. Add to their rug-ged reliability the major benefits of simplified service and maintenance. Performance characteristics of these transmitters include excellent stability and repeatability (better than 0.02% FS). Transmitter span accommodates a 3:1 turndown ratio* to match the application pressure range (i.e. tank depth) and the 4-20 mAdc output is compatible with PLCs or other control architecture using analog I/O. KING-GAGE ES2 transmitters are applicable to most tanks or process vessels whose contents remain at norͭmal atmospheric pressure. They measure hydrostatic head pressure created by liquid depth in the tank and are unaffected by foaming or internal obstructions such as agitators. Unlike load cells, pressure based measurement has lower installation cost and is far simpler to maintain thus ensuring more reliable readings. Transmitters used in sanitary processing must often endure cycles of rapid temperature fluctuation. Wash- down environments produce significant condensation on metallic surfaces that coupled with aggressive cleansing agents demand robust protection for these instruments. The ES2 transmitter's enhanced design uses encapsulation for full isolation of the internal electronics. This extends to the IP68 grade M12 signal connector that ensure in-tegrity and long term reliability. You can be assured of a transmitter truly built for the demands and expectations of today's processing environment. Sanitary Configurations These sensors are especially suited to a wide range of sanitary applications on storage or continuous processing vessels. The 316 stainless diaphragm is appropriate for flush mount, clean-in-place installation employing an FDA-approved silicone rubber O-ring seal to achieve the crevice-free, positive compression seal between dia-phragm and tank liner. Sanitary tank mountings include flush weld mountings with product contact surfaces of 316L stainless. (Quick disconnect sanitary adapters are also available for sensor mounting.) KING-GAGE * 3:1 turndown ratio is applicable to 0-10 and 0-30 nominal range, refer to specifications for detailed span adjustment available on specific range models. ^^͋aiTlNG engineering division www.king-gage.com
Open the catalog to page 1KING-GAGE® ES2 Slimline Transmitter Supplשment 1100-34 You can choose from a number of KING-GAGE display options to complement the ES2 for a complete tank level gauging system. These in-clude digital indicators, HMI touch panels, and integrated networking solutions. Accurate tank gauging can be achieved using KING-GAGE indicators that convert the proportional output into a volumetric measurement of tank level. Performance and Reliability Unlike some other transmitters, ES2 has virtu-ally no position sensitivity and its fast thermal recovery accommodates sanitary process environ-ments. The...
Open the catalog to page 2KING-GAGE® ES2 Slimline Transmitter Supplשment 1100-34 Specifications Span Adjustment Range Transmitter turndown ratio is 3:1 for the 0-15 psig, 0-30 psig and 0-50 psig nominal ranges. Nominal Minimum Range of Adjustment 0-5 psig 0-3 psig 0-83 in. thru 0-138 in. water / 0-2.1 m thru 0-3.5 m water 0-10 psig 0-3 psig 0-15 psig 0-3 psig 0-83 in. thru 0-277 in. water / 0-2.1 m thru 0-7.0 m water 0-83 in. thru 0-415 in. water / ES2 Slimline Transmitter in Washdown Environment 0-2.1 m thru 0-10.5 m water 0-30 psig 0-10 psig 0-277 in. thru 0-830 in. water / 0-7.0 m thru 0-21.0 m water 0-50 psig...
Open the catalog to page 3KING-GAGE® ES2 Slimline Transmitter Supplשment 1100-34 ES2 Slimline Model 5503 (Long Mount) 8.87in. 225 mm Model No. Dsignations Installation Options The KING-GAGE ES2 transmitter offers a choice of configurations to match your application needs. The integral stainless steel housing shown here includes a watertight connector for signal cable installation. Mounting lengths offered are intended to mate with tank fittings on non-insulated (single-wall) or insulated wall tanks. Adapters provide additional mounting options when retrofitting systems from other manufacturers. 550[2] -[3 - 05S...
Open the catalog to page 4All Marsh Bellofram catalogs and technical brochures
-
Full Catalog BelGAS
307 Pages
-
5204
1 Pages
-
P627 High Flow Gas Regulator
10 Pages
-
P212 Pressure Regulator
16 Pages
-
P200 Pressure Regulator
19 Pages
-
P95H Regulator
15 Pages
-
P99 Pressure Reducing Regulator
11 Pages
-
P133 Pressure Regulator
12 Pages
-
P140 Pressure Regulator
4 Pages
-
P303 Pressure Regulator
11 Pages
-
P300 Pressure Regulator
11 Pages
-
P203 Pressure Reducing Regulator
18 Pages
-
F300 Pressure Regulator
7 Pages
-
P600 Pressure Regulator
7 Pages
-
P289RC Exhaust Booster
2 Pages
-
W627 Liquid Gas Regulator
8 Pages
-
F627 High Flow Gas Regulator
7 Pages
-
BELLOFOAM™ 7804
1 Pages
-
BELLOFOAM™ 7704
1 Pages
-
BELLOFOAM™ 7604
1 Pages
-
Marsh Catalog
84 Pages
-
P79 Air Relays
4 Pages
-
Automated Timing & Controls
142 Pages
-
Motor Protection
86 Pages
-
Digital Controllers
30 Pages
-
P630 High Flow Gas Regulator
12 Pages
-
P39 Standard Gas Regulators
4 Pages
-
P40 & P40 NACE Regulators
2 Pages
-
P912 Pressure Regulator
2 Pages
-
P119 Control Valve
4 Pages
-
BelGAS Product Overview LT5040
12 Pages
-
KING-GAGE Product Catalog
12 Pages
-
BelGas P200 Pressure Regulator
18 Pages