Catalog excerpts
BejgAs, A DIVISION OF MARSH B£U-'N P289 P2890801500:: OUTPUT PRESSURE:4 • BEL 103826 WWW.MARSHBELLOFR- Bel gasGas Distribution / Transmission Product CatalogBcIgAs
Open the catalog to page 1BelGAS, the leader in pressure regulator design, offers the Oil, Gas and Pipeline Industry the same precision and reliability in flow control and pressure control that the control valve market has enjoyed for over 40 years. At BelGAS, we have raised the industry standard for quality, accuracy, and dependability. Even more important is that we provide this value to our customers at an economical price. The BelGAS product offering includes pressure regulators for gas, air and propane service; explosion-proof I/P transducers for electro-pneumatic applications; process and test gauges for...
Open the catalog to page 2P627 High Flow Gas Regulator • Wide Range of Flow Capacities • Durable Powder Coated Exterior • Installation Versatility • NACE Construction Available The P627 is a spring loaded, direct-operated regulator for both low and high pressure applications in the oil and gas industries. These regulators provide durability, from the powder-coated epoxy exterior finish, as well as installation versatility, from the multi-position body and spring case configurations. These regulators are also available in an external pressure registration model (P627M), and NACE construction. Applications • Farm Tap...
Open the catalog to page 3P627 Regulator Rebuild Kits Kit Includes Part Number Nitrile diaphragms (2), Nitrile valve disk, O-rings, back-up rings, and retaining pin Nitrile diaphragms (2), Nylon valve disk, O-rings, back-up rings, and retaining pin. Part Number Nitrile diaphragms (2), SS Nitrile valve disk, O-rings, back-up rings, and retaining pin Nitrile diaphragms (2), SS Nylon valve disk, O-rings, back-up rings, and retaining pin NOTE: Nitrile or FKM is recommended for 5-20, 15-40 and 10-95 PSIG. Nylon is recommended for pressures above 150 PSIG or low pressure 3/32" & 1/8" orifice. Steel, LCC Steel or Stainless...
Open the catalog to page 4P627 Flow Capacities of Natural Gas (0.6 S.G.) in SCFH1 Outlet Pressure Range Outlet Pres 1" Body Size Port Diameter, inches 1. Capacity is based on 20 percent droop unless otherwise noted below. 2. For pressure setting under 10 PSIG (0.69 BAR) limit the input pressure to 100 PSIG (6.9 BAR) to obtain the setpoint. 3. For 5 PSIG (0.34 BAR) pressure set point, the droop is 2 PSIG (0.14 BAR)
Open the catalog to page 5P627 Flow Capacities of Natural Gas (0.6 S.G.) in SCFH1 Outlet Pressure Range Outlet Pressure Setting Inlet Pressure Outlet Pressure Range Outlet Pressure Setting Inlet Pressure 1. Capacity is based on 20 percent droop unless otherwise noted below. 2. For pressure setting under 10 PSIG (0.69 BAR) limit the input pressure to 100 PSIG (6.9 BAR) to obtain the setpoint. 3. For 5 PSIG (0.34 BAR) pressure set point, the droop is 2 PSIG (0.14 BAR) 5. Capacities are based on 25 percent boost if setting is less than 12 PSIG (0.8 BAR), 3 PSIG (0.2 BAR) boost if setting is from 12 to 60 PSIG (0.2 to 4...
Open the catalog to page 6P627 Flow Capacities of Natural Gas (0.6 S.G.) in SCFH1 Outlet Pressure Range Outlet Pressure Setting 627 – 2" Body Size Port Diameter, inches Inlet Pressure 627M – 2" Body Size Port Diameter, inches
Open the catalog to page 7P627 Flow Capacities of Natural Gas (0.6 S.G.) in SCFH1 Outlet Pressure Range Outlet Pressure Setting 627H or HM – 3⁄4" Body Size Port Diameter, inches Inlet Pressure 627H or HM – 1" Body Size Port Diameter, inches 1. Capacity is based on 20 percent droop unless otherwise noted below. 4. Outlet pressure setting may shift ±15 PSIG. 6. Small orifices and low pressure drops may cause the set point to shift +15 PSIG (1.3 BAR).
Open the catalog to page 8P627 Flow Capacities of Natural Gas (0.6 S.G.) in SCFH1 Outlet Pressure Setting Outlet Pressure Range Inlet Pressure 627H or HM – 2" Body Size Port Diameter, inches 3/4 Inch Body Wide-Open Cg for Wide-Open Cv for External Relief External Relief Sizing Sizing 6.9 0.24 12.5 0.43 29 1.01 50 1.63 108 2.99 190 4.87 1 Inch (DIN 25) Body Wide-Open Cg Wide-Open Cv for for External Relief External Relief Sizing Sizing 6.9 0.24 12.5 0.43 29 0.93 50 1.71 108 3.42 190 5.29 2 Inch (DIN 50) Body Wide-Open Cg Wide-Open Cv for for External Relief External Relief Sizing Sizing 6.9 0.23 12.5 0.42 29 1.02 52...
Open the catalog to page 9Aluminum/Cast Ductile Iron *F Dimensions for steel P627 and P627M - 120 mm/4.7 inches P627H P627 / R627 Dimensions Flange Units
Open the catalog to page 12Body, Bonnet, Diaphragm Case Body Sizes Orifice Sizes Spring & Diaphragm Casing Style Maximum Inlet Body Pressure Outlet Range 5-20 PSIG Maximum Bonnet and Diaphragm Casing Pressure Maximum pressure to spring and diaphragm casing to prevent leak to atmosphere (internal parts damage may occur). Maximum pressure to spring and diaphragm casings to prevent burst of casings during abnormal operation (leak to atmosphere and internal parts may occur). Maximum diaphragm casing overpressure to prevent damage to internal parts. Temperature Range
Open the catalog to page 13NOTE: Nitrile or FKM is required for 5-20, 15-40 and 10-95 PSIG. Nylon is recommended only up to 1/8" orifice for these pressure ranges. Special Adders None Monitor 150 #RF* 300 #RF* 600 #RF* Socket Weld* 900 #RTJ* 150 #RF & Monitor* 300 #RF & Monitor* 600 #RF & Monitor* Socket Weld & Monitor* *Steel, LCC Steel or Stainless Steel Bodies Only
Open the catalog to page 141. The internal relief performance values are obtained by removing the disk assembly. 2. For inlet pressure in excess of 1000 PSIG (69.0 BAR) refer to the maximum body and disk pressure ratings in the specifications section. 3. For pressure settings under 10 PSIG (0.69 BAR) inlet pressure should be limited to approximately 100 PSIG (6.90 BAR) so the set point adjustment can be obtained. 4. - Shaded areas indicate maximum inlet pressures allowed during system failure only.
Open the catalog to page 15Table Continued
Open the catalog to page 16R627 Capacities for 1 and 2 Inch Body Sizes1 BelGAs Outlet Pressure Table Continued 1. Capacity is based on 20% droop unless otherwise noted below. 2. For pressure setting under 10 PSIG (06.9 BAR) inlet pressure should be limited to approximately 100 PSIF (6.90 BAR) so that setpoint adjustment can be obtained. 3. i - Blank areas indicate where maximum operating inlet pressure for a
Open the catalog to page 17All Marsh Bellofram catalogs and technical brochures
-
Full Catalog BelGAS
307 Pages
-
5204
1 Pages
-
P627 High Flow Gas Regulator
10 Pages
-
P212 Pressure Regulator
16 Pages
-
P200 Pressure Regulator
19 Pages
-
P95H Regulator
15 Pages
-
P99 Pressure Reducing Regulator
11 Pages
-
P133 Pressure Regulator
12 Pages
-
P140 Pressure Regulator
4 Pages
-
P303 Pressure Regulator
11 Pages
-
P300 Pressure Regulator
11 Pages
-
P203 Pressure Reducing Regulator
18 Pages
-
F300 Pressure Regulator
7 Pages
-
P600 Pressure Regulator
7 Pages
-
P289RC Exhaust Booster
2 Pages
-
W627 Liquid Gas Regulator
8 Pages
-
F627 High Flow Gas Regulator
7 Pages
-
BELLOFOAM™ 7804
1 Pages
-
BELLOFOAM™ 7704
1 Pages
-
BELLOFOAM™ 7604
1 Pages
-
Marsh Catalog
84 Pages
-
P79 Air Relays
4 Pages
-
Automated Timing & Controls
142 Pages
-
Motor Protection
86 Pages
-
Digital Controllers
30 Pages
-
P630 High Flow Gas Regulator
12 Pages
-
P39 Standard Gas Regulators
4 Pages
-
P40 & P40 NACE Regulators
2 Pages
-
P912 Pressure Regulator
2 Pages
-
P119 Control Valve
4 Pages
-
BelGAS Product Overview LT5040
12 Pages
-
KING-GAGE Product Catalog
12 Pages
-
BelGas P200 Pressure Regulator
18 Pages