Group: II-VI Incorporated
Catalog excerpts
Thermoelectric Cooler TYPICAL PERFORMANCE VALUES MECHANICAL CHARACTERISTICS SOLID TINNED COPPER NEGATIVE LEAD CERAMIC MATERIAL: ALUMINA (AC) ORDERING OPTIONS AVAILABLE MODIFICATIONS Model Number Description NL2011T-01 both surfaces are metallized NL2011T-02 hot side exterior is metallized Pretinned metallized ceramic surface(s) with 117°C solder. Thermistor mounted on edge of cold side ceramic. (Calibration Elevated temperature burn-in with test data provided.
Open the catalog to page 1ENVIRONMENT: ONE ATMOSPHERE DRY NITROGEN Hot Side Temperature 27°C TYPICAL PERFORMANCE CURVES For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, consult one of our Applications Engineers. Installation Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional information, please refer to our TEC Installation Guide. Operation Cautions For maximum reliability, storage and operation below 85°C in a non-condensing environment is recommended. To minimize thermal stress, use linear/proportional...