Products and prices - 1

Products and prices All prices in this catalogue are gross prices without VAT and valid until 01-07-2020. The prices shown following are in Euro. For UK customers please convert the Euro prices using the conversion rate available on www.fxcentre.com. Prices quoted using the rate on quotation date will remain valid for 30 days. Our prices are subject to change. Copyright © 2019 Mark Climate Technology, Veendam. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without prior written permission of the publisher.

Open the catalog to page 1
Products and prices - 3

Contents Gas-fired air heaters GS+ Gas-fired high performance air heater with axial fan   High efficiency air heater with modulating premix burner for unrestricted outlet into the room. Output from 13,6 to 142,2 kW. Gas-fired air heater with axial fan   Air heater with premix burner for unrestricted outlet into the room. Output from 16,7 to 83,9 kW. G as-fired air heater with axial fan and compact design     Compact air heater with atmospheric burner and electrical ignition for unrestricted outlet into the room. Output from 13,1 to 35,9 kW. Gas and oil-fired heat air heater    Vertical or...

Open the catalog to page 3
Products and prices - 4

TANNER FBA ULTRA Design water-supplied air heater with axial fan Design water-supplied air heater for ceiling installation with RAL9010 coating, suitable for heating and cooling. Powers from 21,4 to 46,2 kW. Water-supplied air heater for recessed ceiling system   Water-supplied air heater for system ceiling with a RAL9010 coating, suitable for heating and cooling. Water-supplied air heater with EC-fan Water-supplied air heater with copper/aluminium heat exchanger. Air amounts from 500 to 2000 m3/h. Water-supplied decentral unit with EC-fan   Water-supplied decentral unit with EC-fan for...

Open the catalog to page 4
Products and prices - 5

Water-supplied radiant heating INFRA AQUA DESIGN Water-supplied aluminium radiation panel  Aluminium radiation panel with a RAL 9010 coating. Water-supplied steel radiation panel Steel radiation panel, available in 4 or 6 metres as standard. Water-supplied radiation panel for grid type ceiling Steel radiation panel, available in standard grid ceiling dimensions. Ventilation and recirculation equipment ECOFAN W Recirculation fan with thermostatic control and isolator switch. Air displacement 4,000 to 14,000m³/h. Roof fan with centrifugal fan. Air displacement 300 to 15,000 m³/h....

Open the catalog to page 5
Products and prices - 6

Modular air handling unit, aluminium. Double-walled insulation. Condensing high efficiency air heater with centrifugal fan     High efficiency air heater with modulating premix burner including for duct connection. Output from 15 to 150 kW. Gas-fired make-up air heater   158 Air heater with burner located directly in the air flow. Output from 64 to 896 kW. Adiabatic cooling  Sustainable ventilation and adiabatic cooling Air displacement 20.000 and 25.000 m3/h. Heat pumps HEAT PUMPS DX-heat pumps Wide range of DX heat pumps with various applications V-Dry coolers with a single row of fans

Open the catalog to page 6
Products and prices - 7

Boilers ECOFLEX High efficiency boiler High efficiency boiler High efficiency boiler High efficiency boiler Hydraulic bending machine BENDER Hydraulic pipe bending machine   Hydraulic pipe bending machine for bending thick-walled pipes. Miscellaneous CONTROL EQUIPMENT     Overview of the control options provided by Mark.

Open the catalog to page 7
Products and prices - 8

The European Commission has determined requirements in the directive 2009/125/EG for the energy consumption of products regarding ecological design. The goal of this directive is to realise a considerable saving on the energy consumption and therewith a reduction of CO2 emissions. This has resulted in the establishment of regulation 1253/2014, which imposes requirements for the ecological design of ventilation units. These requirements have come into force by January 1st 2016 and will be further defined by January 1st 2018. Ecodesign The new regulation 1253/2014 for ventilation products...

Open the catalog to page 8
Products and prices - 9

The new regulation is applicable to the following ventilation units: - Residential ventilation units (RVU): ventilation units with a maximum air flow of not more than 250m3/h or with a maximum air flow between 250 and 1000 m3/h, which according to the producer are exclusively intended for residential ventilation. - Non-residential ventilation units (NRVU): ventilation units with a maximum air flow of more than 250 m3/h, or with a maximum air flow of the ventilation unit between 250 and 1000 m3/h, which according to the producer are not exclusively intended for residential ventilation. Mark...

Open the catalog to page 9
Products and prices - 10

Environmentally friendly heating with the GS+ Mark manufactures a gas-fired, highperformance air heater with an axial fan. This condensing equipment provides efficiency greater than 106% (lower value). Heat is generated via a modulating premixburner which results in very low gas consumption. The GS+ is operated using an Optitherm+ clock thermostat or an Interface+ module that allows a connection with the BMS (building management system) via Modbus or a 0-10V contact. The Optitherm+ also makes it possible to control the GS+ units remotely with an app for mobile phone and tablet (available...

Open the catalog to page 10
Products and prices - 11

Horizontal louvres Gas connection Combustion air inlet Flue gas exhaust Electrical connection Axial fan Condensation connection diam. 40 mm

Open the catalog to page 11
Products and prices - 12

Type Nominal load (upper value) Maximal power Minimal load (upper value) Minimal power Flue efficiency at maximum load (lower value) on/off fan Flue efficiency at maximum load (lower value) modulating fan Flue efficiency at minimum load (lower value) on/off fan Flue efficiency at minimum load (lower value) modulating fan Burner turndown ratio Gas consumption G20 (I5°C) Gas consumption G25 (I5°C) Air displacement (20°C) on/off fan Air displacement (20°C) modulating fan Delta T (AT) on/off fan Delta T (AT) modulating fan Throw Weight of GS+ Noise level (5 m, side) on/off fan Noise level (5 m,...

Open the catalog to page 12

All Mark Climate Technology catalogs and technical brochures

  1. MDV Blue

    14 Pages

  2. ERV

    3 Pages

  3. AHU

    8 Pages

  4. GC+

    6 Pages

  5. CALFLO

    4 Pages

  6. ColdStream

    5 Pages

  7. HEAT PUMPS

    4 Pages

  8. ECOFLEX

    3 Pages

  9. POWERFLEX

    3 Pages

  10. MEGAFLEX

    3 Pages

  11. MAXIFLEX

    1 Pages

  12. Bender

    2 Pages