Power generation Selection guide - Low voltage
66Pages

{{requestButtons}}

Catalog excerpts

Power generation Selection guide - Low voltage - 1

Selection guide - Low Voltage

Open the catalog to page 1
Power generation Selection guide - Low voltage - 2

Content Generator applications Rating definition Operating conditions Connections ODP generators: MXB - MJB | 50 Hz 2. Standard winding 6 poles (rating: 380 - 400 - 415 V) 3. Standard winding 8 poles (rating: 380 - 400 - 415 V) 4. Single phase - parallel star - std. winding 4 poles (rating: 190 - 200 - 208 V) 5. Single phase - zig-zag - std. winding 4 poles (rating: 220 -230 V) TEAAC generators: MJV | 50 Hz TEWAC generators: MJR | 50 Hz 1. 4 poles (rating: 380 - 400 - 415 - 440 V) ODP generators: MXB - MJB | 60 Hz 1. Standard winding 4 poles (rating: 380 - 416 - 440 - 460 - 480 V) 2....

Open the catalog to page 2
Power generation Selection guide - Low voltage - 3

Key TEWAC Totally Enclosed Water to Air Cooled ODP Open Drip Proof TEAAC Totally Enclosed Air to Air Cooled

Open the catalog to page 3
Power generation Selection guide - Low voltage - 4

Operating conditions Rating definition Prime rating Prime rating is the maximum power available at a variable load for an unlimited number of hours. Marelli Motori low voltage generators are class H insulated as a standard feature. Under these conditions three different classes of temperature rise are allowed and are here below represented as over-temperature above the reference ambient temperature (ref. amb. Temp. is 40°C as defined in IEC 60034): Class B temperature rise: generator can reach a temperature rise of 80° above 40° ambient temperature. Class F temperature rise: generator can...

Open the catalog to page 4
Power generation Selection guide - Low voltage - 5

Overloads The nominal power factor is 0,8 lagging. For different power factor values the following derating factors must be applied. This overloads must be occasional and followed by one hour of running at normal load or less. Stand-by ratings are based on conti-nuos supply of loads for any utility power failure. No overloads are allowed in stand-by duty. 10% for 1 hour Overload during S1 15% for 10 minutes continuous duty 30% for 4 minutes Single phase operation MXB The rated outputs of MXB three-phase (12-wire) wound generators, when reconnected for single phase operation, can be obtained...

Open the catalog to page 5
Power generation Selection guide - Low voltage - 6

12 Leads / Winding code M0 Voltages L-L Voltages Frequency Series Delta (High Delta) Voltages Frequency Series Star (High Wye) Key * Voltage not available on MJB 400 frame - neutral not available

Open the catalog to page 6
Power generation Selection guide - Low voltage - 7

Key * voltage not available on MJB355MB4, MJB400MB4 - neutral not available (l) Voltage not availabe on MXB generators

Open the catalog to page 7
Power generation Selection guide - Low voltage - 8

6 Leads / Winding code 17 - 80 Voltages

Open the catalog to page 8
Power generation Selection guide - Low voltage - 10

ODP Generators MXB - MJB - Standard winding 4 poles (1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 10
Power generation Selection guide - Low voltage - 11

(1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 11
Power generation Selection guide - Low voltage - 12

ODP Generators MXB - MJB - Standard winding 4 poles (1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 12
Power generation Selection guide - Low voltage - 13

(1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 13
Power generation Selection guide - Low voltage - 14

ODP Generators MXB - MJB - Standard winding 6 poles

Open the catalog to page 14
Power generation Selection guide - Low voltage - 16

ODP Generators MXB - MJB - 4 poles - Single phase - parallel star - std. winding (1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 16
Power generation Selection guide - Low voltage - 17

(1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 17
Power generation Selection guide - Low voltage - 18

ODP Generators MXB - MJB - 4 poles - Single phase - parallel star - std. winding (1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 18
Power generation Selection guide - Low voltage - 19

(1' Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 19
Power generation Selection guide - Low voltage - 20

ODP Generators MXB - MJB - 4 poles - Single phase - zig-zag - std. winding MXB - MJB - 4 POLES - single phase 50 Hz (1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 20
Power generation Selection guide - Low voltage - 22

TEAAC Generators MJV - LV 4 poles

Open the catalog to page 22
Power generation Selection guide - Low voltage - 24

TEAAC Generators MJV - LV 6 poles

Open the catalog to page 24
Power generation Selection guide - Low voltage - 25

Continuous duty rating kVA @ Temp. rise over 40 °C ambient temp. 125 AT 105 AT

Open the catalog to page 25
Power generation Selection guide - Low voltage - 26

TEWAC Generators MJR - LV 4 poles Continuous duty rating kVA @ Temp. rise over 40 °C ambient temp. 125 AT 105 AT

Open the catalog to page 26
Power generation Selection guide - Low voltage - 27

Continuous duty rating kVA @ Temp. rise over 40 °C ambient temp. 105 AT Cl. F

Open the catalog to page 27
Power generation Selection guide - Low voltage - 28

TEWAC Generators MJR - LV 6 poles

Open the catalog to page 28
Power generation Selection guide - Low voltage - 30

ODP Generators MXB - MJB - Standard winding 4 poles standard winding Moment of Inertia Weight Continuous duty rating Efficiency (1) Stand-by duty rating kVA @ Temp. rise over 40 °C ambient temp. 125 AT 105 AT 80 AT (1' Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 30
Power generation Selection guide - Low voltage - 31

(1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 31
Power generation Selection guide - Low voltage - 32

ODP Generators MXB - MJB - Standard winding 4 poles (1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 32
Power generation Selection guide - Low voltage - 33

(1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 33
Power generation Selection guide - Low voltage - 34

ODP Generators MXB - MJB - Standard winding 4 poles (1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 34
Power generation Selection guide - Low voltage - 36

ODP Generators MJB - Standard winding 6 poles MJB - 6 POLES 460 V standard winding Continuous duty rating kVA @ Temp. rise over 40 °C ambient temp. Stand-by duty rating Moment of Inertia Weight J

Open the catalog to page 36
Power generation Selection guide - Low voltage - 38

ODP Generators MJB - Standard winding 8 poles

Open the catalog to page 38
Power generation Selection guide - Low voltage - 39

MJB - 4 POLES380 V dedicated winding R3 Leads Continuous duty rating kVA @ Temp. rise over 40 °C ambient temp.

Open the catalog to page 39
Power generation Selection guide - Low voltage - 40

ODP Generators MXB - MJB - 60 Hz dedicated winding

Open the catalog to page 40
Power generation Selection guide - Low voltage - 42

ODP Generators MXB - MJB - 4 poles - Single phase - parallel star - std. winding (1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 42
Power generation Selection guide - Low voltage - 43

(1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 43
Power generation Selection guide - Low voltage - 44

ODP Generators MXB - MJB - 4 poles - Single phase - parallel star - std. winding (1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 44
Power generation Selection guide - Low voltage - 45

(1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 45
Power generation Selection guide - Low voltage - 46

ODP Generators MXB - MJB - 4 poles - Single phase - parallel star - dedicated winding

Open the catalog to page 46
Power generation Selection guide - Low voltage - 47

(1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 47
Power generation Selection guide - Low voltage - 48

ODP Generators MXB - MJB - 4 poles - Single phase - zig-zag - std. winding (1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 48
Power generation Selection guide - Low voltage - 49

(1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 49
Power generation Selection guide - Low voltage - 50

ODP Generators MXB - MJB - 4 poles - Single phase - zig-zag - std. winding (1) Value referred to continuous duty rating / 125 AT / Temperature rise class H

Open the catalog to page 50

All Marelli Motori S.p.A. catalogs and technical brochures

  1. B4V B4VH

    4 Pages

  2. B4W

    4 Pages

  3. A5M B5M

    4 Pages

  4. MJRM

    7 Pages

  5. B4JH B5JH

    4 Pages

  6. D5U

    4 Pages

  7. D5H

    4 Pages

  8. Services

    7 Pages