DS DECONTACTOR-1

► Automatic IP54/55 ► Optional IP66 from 90 A ► Integrated load break switch: AC-22 and AC-23 breaking capacity ► Chemical resistant GRP UL 94 casing up to 150 A ► Metal casing (IK09) from 90 A to 400 A with epoxy paint

 Open the catalog to page 1
DS DECONTACTOR-2

TECHNICAL FEATURES Plugs and sockets with integral load-break switching capability complying with IEC/EN 60309-1 and IEC/EN 60309-4 standards DS1 DS3 DS6 DS9 DS2 DS4 Auxiliary contacts (optional) 2 4 4 6 6 UNDERWRITERS LABORATORIES STANDARDS AUSTRALIA DS DECONTACTOR™ complies with: • IEC/EN 60309-1 & IEC/EN 60309-4 European and International standards (plugs and socket-outlets for industrial purposes), • The European Low Voltage Directive 2014/35/EU, conformity with the CE marking, • The European 'Machine Directive' 2006/42/CE regarding equipment isolation, • The...

 Open the catalog to page 2
DS DECONTACTOR-3

DECONTACTOR™ GRP 30 AIP55 WALL MOUNTING SOCKET DSl Wall box poly 30° Socket-outlet512B3M20 3114017 PLUG DSl Maximum voltage 690 V Flexible wiring (min-max) IP55 Stranded wiring (min-max) IP protection plug connected Shock resistance Keying positions Load-break capability of the DECONTACTOR™ Comply with IEC/EN 60309-1 and IEC/EN 60309-4 standards Load-break capability according to IEC/EN 60947-3/AC-22 A Load-break capability according to IEC/EN 60947-3/AC-23 A Short-circuit current Icc Power kW AC-22/AC-23 Dual-voltage socket-outlet (see p. 7) SOCKET-OUTLET female DSl (30 A) ► Other voltages,...

 Open the catalog to page 3
DS DECONTACTOR-4

Straight handle poly 513P0D30 MAIN FEATURES Rated current (with wiring according to standard) Maximum voltage Ambient temperature Flexible wiring (min-max) Stranded wiring (min-max) IP protection plug connected Other wiring Shock resistance Keying positions Load-break capability of the DECONTACTOR™ Comply with IEC/EN 60309-1 and IEC/EN 60309-4 standards Load-break capability according to IEC/EN 60947-3/AC-22 A Load-break capability according to IEC/EN 60947-3/AC-23 A Other voltages, frequencies and contact configurations are available (see page 10). OPTIONS AND ACCESSORIES Find the boxe

 Open the catalog to page 4
DS DECONTACTOR-5

DECONTACTOR™ GRP 90 AIP55 WALL MOUNTING SOCKET DS6 Wall box poly 30° Socket-outlet514B3M32 3164017 PLUG DS6 Maximum voltage 1 000 V Flexible wiring (min-max) IP55 Stranded wiring (min-max) IP protection plug connected Shock resistance (poly casing) Keying positions Load-break capability of the DECONTACTOR™ Comply with IEC/EN 60309-1 and IEC/EN 60309-4 standards Load-break capability according to IEC/EN 60947-3/AC-22 A Load-break capability according to IEC/EN 60947-3/AC-23 A Short-circuit current Icc Power kW AC-22/AC-23 Auxiliaries 5 A/500 V AC + 4 contacts Ref. + 264 Ref. + 264...

 Open the catalog to page 5
DS DECONTACTOR-6

90 AIP55 WALL MOUNTING SOCKET DS6 Wall box metal 30° Socket-outlet594B2M25 3964017Straight handle poly Inlet514P0D35 3968017MAIN FEATURESRated current (with wiring according to standard) 90 A Ambient temperature -40 °C to +60 °C Maximum voltage 1 000 V Flexible wiring (min-max) 10-25 mm2 IP55 Stranded wiring (min-max) IP protection plug connected Shock resistance (metal casing) Load-break capability of the DECONTACTOR™ Comply with IEC/EN 60309-1 and IEC/EN 60309-4 standards Load-break capability according to IEC/EN 60947-3/AC-22 A Load-break capability according to IEC/EN 60947-3/AC-23...

 Open the catalog to page 6
DS DECONTACTOR-7

Straight elastomer 555P0D35 Inlet 3198017 MAIN FEATURESRated current (with wiring according to standard) 150 A Ambient temperature -40 °C to +60 °C Maximum voltage 1 000 V Flexible wiring (min-max) 25-70 mm2 IP66/IP67 Stranded wiring (min-max) IP protection plug connected Shock resistance (poly casing) Load-break capability of the DECONTACTOR™ Comply with IEC/EN 60309-1 and IEC/EN 60309-4 standards Load-break capability according to IEC/EN 60947-3/AC-22 A Load-break capability according to IEC/EN 60947-3/AC-23 A Short-circuit current Icc Power kW AC-22/AC-23 Dual-voltage socket-outlet (see p....

 Open the catalog to page 7
DS DECONTACTOR-8

DECONTACTOR™ METAL WALL MOUNTING SOCKET DS9 595C7M40 3994017 Straight elastomer Inlet 555P0D35 3998017MAIN FEATURESRated current (with wiring according to standard) 150 A Ambient temperature -40 °C to +60 °C Maximum voltage 1 000 V Flexible wiring (min-max) 25-70 mm2 IP55 Stranded wiring (min-max) IP protection plug connected Shock resistance (metal casing) Load-break capability of the DECONTACTOR™ Comply with IEC/EN 60309-1 and IEC/EN 60309-4 standards Load-break capability according to IEC/EN 60947-3/AC-22 A Load-break capability according to IEC/EN 60947-3/AC-23 A Short-circuit current...

 Open the catalog to page 8
DS DECONTACTOR-9

DECONTACTOR™ METAL MAIN FEATURES Rated current (with wiring according to standard) Maximum voltage Ambient temperature Flexible wiring (min-max) Stranded wiring (min-max) IP protection plug connected Keying positions Shock resistance Load-break capability of the DECONTACTOR™ Comply with IEC/EN 60309-1 and IEC/EN 60309-4 standards Load-break capability according to IEC/EN 60947-3/AC-22 A Load-break capability according to IEC/EN 60947-3/AC-23 A Other voltages, frequencies and contact configurations are available (see page 10). For more than 2 auxiliary contacts, please contact us.

 Open the catalog to page 9
DS DECONTACTOR-10

MAIN FEATURES Rated current (with wiring according to standard) Stranded wiring (min-max) Shock resistance Ambient temperature Keying positions Connector only: not to be disconnected while energised Pilot contacts 5 A/400 V AC for electrical interlock Mechanical interlock Inlet closing device in stainless steel REMEMBER TO ORDER AN OPTIONAL SPACER Creates more space for easier wiring, thickness 68 mm : 577M0-68, thickness 115 mm : 577M0-115. Flexible wiring (min-max) Maximum voltage OPTIONS AND ACCESSORIES Find the boxes, sleeves and handles at the e

 Open the catalog to page 10
DS DECONTACTOR-11

OPTIONS (DETAILS ON PAGE 216) DS1 size 2 INDUSTRIAL-DOMESTIC ADAPTERS Industrial inlet MARECHAL® 1P+N+E domestic socket-outlet 10/16 A 230 V fuse protection 10 A and 16 A. * ll these plug adapters are available to foreign standards: replace D11 by D40 for UK, D30 for Germany/NL/Lux, D06 for Italy. A LOCKING PIN FOR 2 PADLOCKS Ø 8 mm (PADLOCKS NOT SUPPLIED) Socket-outlet Socket-outlet Socket-outlet Socket-outlet Socket-outlet Socket-outlet ref. + 843 ref. + 843 ref. + 843 ref. + 843 ref. + 843 ref. + 843 SAFETY HASP FOR UP TO 6 PADLOCKS 873A541 LARGER RELEASE BUTTON Socket-outlet Socket-outlet...