The document provides technical specifications for cold light sources models MA 1100, MA 1200, and MA 1300, which are used in precision optical instruments across various fields such as industry, science, medicine, criminology, and photography. These light sources are designed to function optimally with fiber-optic light guides.

Specifications
  • Power Rating: MA 1100 - 10.8V/30W, MA 1200 - 12V/100W, MA 1300 - 21V/150W.
  • Power Consumption: MA 1100 - 50 VA, MA 1200 - 120 VA, MA 1300 - 190 VA.
  • Voltage: Compatible with 100-120V/60 Hz or 230-240V/50 Hz.
  • Illumination: MA 1100 - 8Mlx, MA 1200 - 18Mlx, MA 1300 - 26Mlx.
  • Intensity Control: Infinitely variable via potentiometer and diaphragm for fine adjustment.
  • Color Temperature: Standard max position - 3200 K (MA 1100), 3250 K (MA 1200 and MA 1300); with daylight filter - 5500 K for all models.
  • Lamp Life: Varies by control position, with position 4 offering longer life (770 h for MA 1100, 3000 h for MA 1200, 1500 h for MA 1300) compared to position 6 (70 h for MA 1100, 360 h for MA 1200, 160 h for MA 1300).
  • Additional Features: Heat protection filter, side filter insert, stackability, and overheating protection.
  • Fuses: MA 1100 - 315/630 mA, MA 1200 - 630 mA/1.5 A, MA 1300 - 1 A/2.5 A.
  • Dimensions: 168x120x268 mm for all models.
  • Weight: MA 1100 - 1.3 kg, MA 1200 - 1.5 kg, MA 1300 - 1.6 kg.
See more

Catalog excerpts

   Cold light sources-1

OPTISCHE MESSTECHNIK OPTICAL MEASURING SYSTEMS SYSTEMES DE MESURE OPTIQUE Perfekt funktionierende Kaltlichtquellen in Verbindung mit ausgekl騼gelten faseroptischen Lichtleitern sind die ideale Voraussetzung fr optische Gerte mit h줶chstem Anspruchsniveau, wie sie in Industrie, Wissenschaft, Medizin, Kriminalistik, Fotografie etc. Verwendung finden. Sources de lumire froide combines avec guides de lumi詨re fibres optiques correspondant aux demandes exigeantes en matire de prcision pour instruments optiques utilis詩s dans l'industrie, science, mdecine, criminologie, photographie etc. Perfectly functioning cold light sources combined with sophisticated fiber-optic light guides meet the demands for the precision optical instruments used in industry, science, medicine, criminology, photography etc. > z01_ma1100_1300 / 280308 size="-2">

 Open the catalog to page 1
   Cold light sources-2

Leistung 10.8V/30W 12V/100W 21V/150W Leistungsaufnahme 50 VA 120 VA 190 VA Spannung : 100 - 120V / 60 Hz oder 230 - 240V / 50 Hz Beleuchtungsstrke 8Mlx 18Mlx 26Mlx Helligkeitsregulierung durch Potentiometer stufenlos stufenlos stufenlos Helligkeitsregulierung durch Blende (Feineinstellung) stufenlos stufenlos stufenlos Farbtemperatur : bei max. Standardposition 3200 K 3250 K 3250 K mit Tageslichtfilter 5500 K 5500 K 5500 K Lampenlebensdauer : Reglerposition 4 770 h 3000 h 1500 h Reglerposition 6 70 h 360 h 160 h W褤rmeschutzfilter Filtereinschub seitlich Stapelbarkeit berhitzungsschutz Sicherungen...

 Open the catalog to page 2

All Marcel Aubert S.A. catalogs and technical brochures

  1. Catalog

    24  Pages

  2. Catalog

    25  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.