video corpo

LCA20

LCA20

LCA20

Product catalog summary
User Benefits
  • Enhanced stability and response time for load cell inputs and analogue outputs.
  • Digital setup and calibration via keypad or PC.
  • Versatile output options including analogue, data, set point, and display capabilities.
  • Simple calibration process and easy configuration using LCA Toolkit software.
  • Available in various mounting options including DIN Rail, PCB module, or stainless steel case.
Ideal Applications
  • Civil Engineering
  • Agriculture
  • Industrial Processing
Product Overview

The LCA20 is an upgraded version of the LCA15, featuring a new microprocessor and RISC technology. It allows parameter selection via PC or keypad, eliminating the need for on-PCB switches. The LCB20 is a PCB-only version suitable for DIN rail mounting.

Key Specifications
  • RS485 and RS232 digital data output.
  • Measurement speeds of 10/80 samples per second.
  • Factory calibration in mV/V with 5 V excitation supporting up to 10 x 350 R load cells.
  • Fully isolated 4-20 mA and 0-10 V analogue outputs.
  • 6-wire input for barrier and cable loss compensation.
  • 2 set points SPCO relay outputs and sensitivity from 0.5 to 7.8 mV/V.
  • 10-point linearization and 3 configurable digital inputs.
  • Firmware supports Mantrabus 1 & 2, MANTRA ASCII 2 & MODBUS RTU.
  • ROHS Compliant and environmentally sealed to IP65/NEMA 4.
Case Study

A plant-based herbal product supplier used the LCA20 to control a chemical spray application. The system, integrated with ADP15 indicators and LCA Toolkit software, ensured precise spray application based on product flow rate measured by a load cell.

Environmental Specifications
  • Storage Temperature: -20 to +70ºC
  • Operating Temperature: -10 to +50ºC
  • Relative Humidity: 95% maximum non-condensing
  • IP Rating: IP65 / NEMA 4
Compliance
  • CE Environmental Approvals
  • European EMC Directive 2004/108/EC
  • Low Voltage Directive 2006/95/EC
See more

Catalog excerpts

LCA20-1

LCA20 & LCB20 Load Cell Amplifier with Data Outputs RS232 & RS485 New Design PCB User Benefits The ROHS Compliant LCA20 flexible digital signal conditioning amplifier for multiple or single load cell applications, offering very easy one-pass calibration and fast set-up Improved stability of load cell input Improved analogue output response time Full digital set-up and calibration using keypad or PC Easy load cell sensitivity selection set by PC or keypad Analogue and data output, set point and display capabilities AC or DC powered Simple one pass calibration Easy configuration using LCA Toolkit software Available with DIN Rail mounting or PCB module or a stainless steel case Introduction The LCA15 has been redesigned to become the LCA20 taking advantage of new technology with improved performance and increased functionality. The external appearance and dimensions of the LCA20 remains the same as the LCA15. In addition to the introduction of a new microprocessor and using the latest RISC technology, the LCA20 has many new features such as the selection of device parameters via a PC or keypad rather than using the traditional on-PCB switches. A PCB only version, which can be DIN rail mounted, is also available as the LCB20. RS485 and RS232 digital data output for communications and printing Measurement speeds 10 / 80 samples per sec Factory calibration in mV/V 5 V excitation supports up to 10 x 350 R load cells Fully isolated 4-20 mA and 0-10 V analogue outputs 6 wire input to compensate for barrier and cable losses 2 set points SPCO relay outputs Sensitivity from 0.5 to 7.8 mV/V 10 pt linearization 3 x configurable digital inputs e.g. for auto tare, peak hold and reset Firmware now supports Mantrabus 1 & 2, MANTRA ASCII 2 & MODBUS RTU ROHS Compliant & Environmentally sealed to IP65 / NEMA 4 enclosure dimensions 200 x 120 x 75 mm Civil Engineering Industrial Processing

 Open the catalog to page 1
LCA20-2

Related Product LCB20 Digital load cell amplifier with data & relay outputs ADP15 Universal digital panel meter for measuring 4-20 mA, 0-10 V RS485/232 Communications (supports MODBUS RTU, ASCII, MANTRABUS 1 & MANTRABUS 2) Related Software LCA Toolkit Quick set up software event monitoring, data logging, calibration and configuration Instrument Explorer Quick set up software event monitoring, data logging, calibration and configuration Case Study The Application: The supplier of a plant based herbal product had a problem with potential decay-causing organisms affecting the quality of the material...

 Open the catalog to page 2

All Mantracourt Electronics Ltd catalogs and technical brochures

  1. UAB

    2  Pages

  2. X24-SAe

    2  Pages

  3. B24

    2  Pages

  4. T24-ACM

    2  Pages

  5. T24-WSS

    2  Pages

  6. ADW-BW

    2  Pages

  7. ADW-SP16

    2  Pages

  8. ADP15

    2  Pages

  9. ADP-SP16

    2  Pages

  10. LVDT

    2  Pages

  11. SGA

    2  Pages

  12. SMW

    2  Pages

  13. SMW-HR

    2  Pages

  14. SMP

    2  Pages

  15. LCI

    2  Pages

  16. LCD20

    4  Pages

  17. PSD

    2  Pages

  18. DS485DIS

    2  Pages

  19. DSJ4

    2  Pages

  20. DSJ1

    2  Pages

  21. DCell & DSC

    2  Pages

  22. DCell

    2  Pages

  23. DSCUSB

    2  Pages

  24. ICA H&S

    2  Pages

  25. T24-RA

    4  Pages

  26. PP1 & SP1

    2  Pages

  27. T24-HR

    2  Pages

  28. T24-BSue

    2  Pages

  29. T24-PA

    4  Pages

  30. T24-PR1

    2  Pages

  31. T24LOG100

    1  Page

  32. T24-LD1

    2  Pages

  33. T24-IA

    4  Pages

  34. T24-HS

    2  Pages

  35. T24-HA

    2  Pages

  36. T24-GW1

    2  Pages

  37. T24-BSi

    2  Pages

  38. T24-BSu

    2  Pages

  39. T24-BC1

    2  Pages

  40. T24-AR

    2  Pages

  41. T24-ANT

    1  Page

  42. T24-AO1

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.