Manner sensor telemetry
51Pages

{{requestButtons}}

Catalog excerpts

Manner sensor telemetry - 1

Inductive Sensortelemetry 1 Channel Sensor Signal Amplifiers SunGDitolum otrio

Open the catalog to page 1
Manner sensor telemetry - 2

Position (Differential transformer) Contactless distance (µe transducer) Strain gage halve brigde Strain gage full brigde Remote control (option) Single Channel Sensor Signal Amplifier Inductive supply and transmission 13,56 MHz 0 to ±10V Single Channel Receiver Digital interface (option) Coupling Thermocouple Trace A Trace B Trace 0 PT100 RTD Shaft encoder interface (option) Incremental/ Absolut converter (option) Speed Pickup Remote shunt calibration

Open the catalog to page 2
Manner sensor telemetry - 3

Sensor Signal Amplifier Type 2a 1 Channel FM/PCM Transmitter For strain gage, PT100, Thermocouple Strain gage brigde supply: 2,5 V (3,3 V*) Strain gage bridge resistance: 350 (120, 1000) Q Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 14 Bits, 16 Bits* Zero point drift: 0,02, (0,01, 0,003 option) Remote shunt calibration Remote gain, zero, auto zero with 16 Bit resolution (option) Additonal temperature channel (option) Enviromental temperature range: -25 to +85°C (125°C, 150°C) Max load: 50 000 g (depending on fixing)

Open the catalog to page 3
Manner sensor telemetry - 4

Sensor Signal Amplifier Type 2b (End of shaft, Cartridge, Turbine) Integrated Rotor Coil GND With integrated axial antenna Sensor signal amplifier Weight: 15 g Torque of inertia: 4,2E-7 kgm2 Stator antenna (Pickup) 1 Channel FM/PCM Transmitter For strain gage, PT100, Thermocouple Sensitivity: 0,02 mV/V to 20 mV/V Bandwidth: 0 (10) Hz to 50 kHz Strain gage brigde supply: 2,5 V (3,3 V*) Strain gage bridge resistance: 350 (120, 1000) W Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 14 Bits, 16 Bits* Zero point drift: 0,02, (0,01, 0,003 option) Remote shunt...

Open the catalog to page 4
Manner sensor telemetry - 5

Sensor Signal Amplifier Type 2c (End of shaft, Miniatur Cartridge, Turbine) Sensor signal End of shaft Stator antenna (Pickup) 1 Channel FM/PCM Transmitter green black white blue HF 2 golden enamelled wires twisted For strain gage, PT100, Thermocouple Sensitivity: 0,02 mV/V to 20 mV/V Bandwidth: 0 (10) Hz to 50 kHz Strain gage brigde supply: 2,5 V (3,3 V*) Strain gage bridge resistance: 350 (120, 1000) W Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 14 Bits, 16 Bits* Zero point drift: 0,02, (0,01, 0,003 option) Remote shunt calibration Remote gain, zero, auto...

Open the catalog to page 5
Manner sensor telemetry - 6

Sensor Signal Amplifier Type 2d (End of shaft, Micro Cartridge, Turbine) End of shaft Sensor signal amplifier Integrated Rotor Coil Stator antenna (Pickup) 1 Channel FM/PCM Transmitter red green black white blue HF 2 golden enamelled wires twisted For strain gage, PT100, Thermocouple Sensitivity: 0,02 mV/V to 20 mV/V Bandwidth: 0 (10) Hz to 50 kHz Strain gage brigde supply: 2,5 V (3,3 V*) Strain gage bridge resistance: 350 (120, 1000) W Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 16 Bits Zero point drift: 0,02, (0,01, 0,003 option) Remote shunt calibration...

Open the catalog to page 6
Manner sensor telemetry - 7

Sensor Signal Amplifier Type 2e (Disk, End of shaft, Small space) (Radial coupling) 6 x M3 Inbus Solder pins 1 Channel FM/PCM Transmitter For strain gage, PT100, Thermocouple Sensitivity: 0,02 mV/V to 20 mV/V Bandwidth: 0 (10) Hz to 50 kHz Strain gage brigde supply: 2,5 V (3,3 V*) Strain gage bridge resistance: 350 (120, 1000) W Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 14 Bits, 16 Bits* Zero point drift: 0,02, (0,01, 0,003 option) Remote shunt calibration Remote gain, zero, auto zero with 16 Bit resolution (option) Additonal temperature channel (option)...

Open the catalog to page 7
Manner sensor telemetry - 8

Wheel Transmitter with integrated Signal Amplifier Type 2f Range conditioning For more information see section: Universal shaft transmitter 1 Channel FM/PCM Transmitter Beared wheel transmitter For strain gage, PT100, Thermocouple Strain gage brigde supply: 6 V (3,3 V* Strain gage bridge resistance: 120, 350, 1000 Q Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 14 Bits, 16 Bits Zero point drift: 0,02, (0,01, 0,003* option) Remote shunt calibration Speed detection: 360 pulses/turn Enviromental temperature range: -25 to +85°C (125°C,

Open the catalog to page 8
Manner sensor telemetry - 9

Universal Shaft Transmitter with Sensor Signal Amplifier Type 2La (non divisible, 1 channel,with/without RMC, without rpm sensor) UB Speed detection Option Speed 1 Channel FM/PCM Transmitter Beared wheel transmitter For strain gage, PT100, Thermocouple Sensitivity: 0,02 mV/V to 20 mV/V Bandwidth: 0 (10) Hz to 10 kHz Strain gage brigde supply: 6 V (3,3 V*) Strain gage bridge resistance: 120, 350, 1000 W Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 16 Bits Zero point drift: 0,02, (0,01, 0,003* option) Remote shunt calibration Type: SV_2La_______TC_ in mm in mm...

Open the catalog to page 9
Manner sensor telemetry - 10

Universal Shaft Transmitter with Sensor Signal Amplifier Type 2Lg (divisible, 1 channel,with/without RMC, without rpm sensor) UB Speed detection Option Speed Beared wheel transmitter For strain gage, PT100, Thermocouple Sensitivity: 0,02 mV/V to 20 mV/V Bandwidth: 0 (10) Hz to 10 kHz Strain gage brigde supply: 6 V (3,3 V*) Strain gage bridge resistance: 120, 350, 1000 W Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 16 Bits Zero point drift: 0,02, (0,01, 0,003* option) Remote shunt calibration Type: SV_2Lg_______TC_ in mm in mm 36 59 -10+85°C PCM16 1 kHz 24 65...

Open the catalog to page 10
Manner sensor telemetry - 11

Sensor Signal Amplifier Type 3a 1 Channel FM/PCM Transmitter For strain gage, PT100, Thermocouple Strain gage brigde supply: 2,5 V (3,3 V*) Strain gage bridge resistance: 350 (120, 1000) Q Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 14 Bits, 16 Bits* Zero point drift: 0,02, (0,01, 0,003 option) Remote shunt calibration Remote gain, zero, auto zero with 16 Bit resolution (option) Additonal temperature channel (option) Enviromental temperature range: -25 to +85°C (125°C, 160°C) Max load: 50 000 g (depending on fixing)

Open the catalog to page 11
Manner sensor telemetry - 12

Sensor Signal Amplifier Type 3B UB 1 Channel FM/PCM Transmitter For strain gage, PT100, Thermocouple Sensitivity: 0,02 mV/V to 20 mV/V Bandwidth: 0 (10) Hz to 50 kHz Strain gage brigde supply: 2,5 V (3,3 V*) Strain gage bridge resistance: 350 (120, 1000) W Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 14 Bits, 16 Bits* Zero point drift: 0,02, (0,01, 0,003 option) Remote shunt calibration Remote gain, zero, auto zero with 16 Bit resolution (option) Additonal temperature channel (option) Enviromental temperature range: -25 to +85°C (125°C, 160°C) Max load: 50...

Open the catalog to page 12

All Manner Sensortelemetrie catalogs and technical brochures