1. Catalogs
  2. Manner Sensortelemetrie
  3. Manner sensor telemetry

Manner sensor telemetry
1 /51Pages

Manner sensor telemetry

Manner sensor telemetry
1 /51Pages

Catalog excerpts

Manner sensor telemetry-1

Inductive Sensortelemetry 1 Channel Sensor Signal Amplifiers SunGDitolum otrio

 Open the catalog to page 1
Manner sensor telemetry-2

Position (Differential transformer) Contactless distance (µe transducer) Strain gage halve brigde Strain gage full brigde Remote control (option) Single Channel Sensor Signal Amplifier Inductive supply and transmission 13,56 MHz 0 to ±10V Single Channel Receiver Digital interface (option) Coupling Thermocouple Trace A Trace B Trace 0 PT100 RTD Shaft encoder interface (option) Incremental/ Absolut converter (option) Speed Pickup Remote shunt calibration

 Open the catalog to page 2
Manner sensor telemetry-3

Sensor Signal Amplifier Type 2a 1 Channel FM/PCM Transmitter For strain gage, PT100, Thermocouple Strain gage brigde supply: 2,5 V (3,3 V*) Strain gage bridge resistance: 350 (120, 1000) Q Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 14 Bits, 16 Bits* Zero point drift: 0,02, (0,01, 0,003 option) Remote shunt calibration Remote gain, zero, auto zero with 16 Bit resolution (option) Additonal temperature channel (option) Enviromental temperature range: -25 to +85°C (125°C, 150°C) Max load: 50 000 g (depending on fixing)

 Open the catalog to page 3
Manner sensor telemetry-4

Sensor Signal Amplifier Type 2b (End of shaft, Cartridge, Turbine) Integrated Rotor Coil GND With integrated axial antenna Sensor signal amplifier Weight: 15 g Torque of inertia: 4,2E-7 kgm2 Stator antenna (Pickup) 1 Channel FM/PCM Transmitter For strain gage, PT100, Thermocouple Sensitivity: 0,02 mV/V to 20 mV/V Bandwidth: 0 (10) Hz to 50 kHz Strain gage brigde supply: 2,5 V (3,3 V*) Strain gage bridge resistance: 350 (120, 1000) W Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 14 Bits, 16 Bits* Zero point drift: 0,02, (0,01, 0,003 option) Remote shunt calibration...

 Open the catalog to page 4
Manner sensor telemetry-5

Sensor Signal Amplifier Type 2c (End of shaft, Miniatur Cartridge, Turbine) Sensor signal End of shaft Stator antenna (Pickup) 1 Channel FM/PCM Transmitter green black white blue HF 2 golden enamelled wires twisted For strain gage, PT100, Thermocouple Sensitivity: 0,02 mV/V to 20 mV/V Bandwidth: 0 (10) Hz to 50 kHz Strain gage brigde supply: 2,5 V (3,3 V*) Strain gage bridge resistance: 350 (120, 1000) W Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 14 Bits, 16 Bits* Zero point drift: 0,02, (0,01, 0,003 option) Remote shunt calibration Remote gain, zero, auto zero...

 Open the catalog to page 5
Manner sensor telemetry-6

Sensor Signal Amplifier Type 2d (End of shaft, Micro Cartridge, Turbine) End of shaft Sensor signal amplifier Integrated Rotor Coil Stator antenna (Pickup) 1 Channel FM/PCM Transmitter red green black white blue HF 2 golden enamelled wires twisted For strain gage, PT100, Thermocouple Sensitivity: 0,02 mV/V to 20 mV/V Bandwidth: 0 (10) Hz to 50 kHz Strain gage brigde supply: 2,5 V (3,3 V*) Strain gage bridge resistance: 350 (120, 1000) W Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 16 Bits Zero point drift: 0,02, (0,01, 0,003 option) Remote shunt calibration Remote...

 Open the catalog to page 6
Manner sensor telemetry-7

Sensor Signal Amplifier Type 2e (Disk, End of shaft, Small space) (Radial coupling) 6 x M3 Inbus Solder pins 1 Channel FM/PCM Transmitter For strain gage, PT100, Thermocouple Sensitivity: 0,02 mV/V to 20 mV/V Bandwidth: 0 (10) Hz to 50 kHz Strain gage brigde supply: 2,5 V (3,3 V*) Strain gage bridge resistance: 350 (120, 1000) W Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 14 Bits, 16 Bits* Zero point drift: 0,02, (0,01, 0,003 option) Remote shunt calibration Remote gain, zero, auto zero with 16 Bit resolution (option) Additonal temperature channel (option) Enviromental...

 Open the catalog to page 7
Manner sensor telemetry-8

Wheel Transmitter with integrated Signal Amplifier Type 2f Range conditioning For more information see section: Universal shaft transmitter 1 Channel FM/PCM Transmitter Beared wheel transmitter For strain gage, PT100, Thermocouple Strain gage brigde supply: 6 V (3,3 V* Strain gage bridge resistance: 120, 350, 1000 Q Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 14 Bits, 16 Bits Zero point drift: 0,02, (0,01, 0,003* option) Remote shunt calibration Speed detection: 360 pulses/turn Enviromental temperature range: -25 to +85°C (125°C,

 Open the catalog to page 8
Manner sensor telemetry-9

Universal Shaft Transmitter with Sensor Signal Amplifier Type 2La (non divisible, 1 channel,with/without RMC, without rpm sensor) UB Speed detection Option Speed 1 Channel FM/PCM Transmitter Beared wheel transmitter For strain gage, PT100, Thermocouple Sensitivity: 0,02 mV/V to 20 mV/V Bandwidth: 0 (10) Hz to 10 kHz Strain gage brigde supply: 6 V (3,3 V*) Strain gage bridge resistance: 120, 350, 1000 W Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 16 Bits Zero point drift: 0,02, (0,01, 0,003* option) Remote shunt calibration Type: SV_2La_______TC_ in mm in mm 36...

 Open the catalog to page 9
Manner sensor telemetry-10

Universal Shaft Transmitter with Sensor Signal Amplifier Type 2Lg (divisible, 1 channel,with/without RMC, without rpm sensor) UB Speed detection Option Speed Beared wheel transmitter For strain gage, PT100, Thermocouple Sensitivity: 0,02 mV/V to 20 mV/V Bandwidth: 0 (10) Hz to 10 kHz Strain gage brigde supply: 6 V (3,3 V*) Strain gage bridge resistance: 120, 350, 1000 W Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 16 Bits Zero point drift: 0,02, (0,01, 0,003* option) Remote shunt calibration Type: SV_2Lg_______TC_ in mm in mm 36 59 -10+85°C PCM16 1 kHz 24 65 -25+125°C...

 Open the catalog to page 10
Manner sensor telemetry-11

Sensor Signal Amplifier Type 3a 1 Channel FM/PCM Transmitter For strain gage, PT100, Thermocouple Strain gage brigde supply: 2,5 V (3,3 V*) Strain gage bridge resistance: 350 (120, 1000) Q Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 14 Bits, 16 Bits* Zero point drift: 0,02, (0,01, 0,003 option) Remote shunt calibration Remote gain, zero, auto zero with 16 Bit resolution (option) Additonal temperature channel (option) Enviromental temperature range: -25 to +85°C (125°C, 160°C) Max load: 50 000 g (depending on fixing)

 Open the catalog to page 11
Manner sensor telemetry-12

Sensor Signal Amplifier Type 3B UB 1 Channel FM/PCM Transmitter For strain gage, PT100, Thermocouple Sensitivity: 0,02 mV/V to 20 mV/V Bandwidth: 0 (10) Hz to 50 kHz Strain gage brigde supply: 2,5 V (3,3 V*) Strain gage bridge resistance: 350 (120, 1000) W Transmission: inductive sensortelemetry FM, PCM Integrated filter Resolution: 14 Bits, 16 Bits* Zero point drift: 0,02, (0,01, 0,003 option) Remote shunt calibration Remote gain, zero, auto zero with 16 Bit resolution (option) Additonal temperature channel (option) Enviromental temperature range: -25 to +85°C (125°C, 160°C) Max load: 50 000...

 Open the catalog to page 12

All Manner Sensortelemetrie catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.