Assembly and Installation Instructions
The unit comprises four main assemblies: ADAPTOR frame, SLIDE assembly, HOPPER assembly, and CONTROLLER/Drive unit. Key steps include attaching the CONTROLLER to the SLIDE assembly, mounting the ADAPTOR frame under the hopper, and ensuring proper alignment for the removable hopper and controller.
Startup Instructions
Connect the "CONTINUOUS POWER" cord to a 120-volt source and the "SIGNAL" cord to an outlet that activates with the screw. Use the provided formula to set the counter for different colors and metering rates. The controller adjusts auger speed automatically with the process machine screw.
Normal Operation
During normal operation, the display should read zero without power to the SIGNAL cord. The motor starts at about 10 RPMs when powered, counting down from the set number. Motor speed adjusts based on cycle length, with blinking indicating speed discrepancies.
Formulas for Setting the Counter
For injection molding, calculate the counter setting using shot weight, pounds per 100 of color required, and metering rate. For extrusion, use extruder output, pounds of color per 100 pounds natural, and metering rate.
Determining Metering Rate
Metering rates vary by color due to differences in bulk densities and flow characteristics. This can be determined with the feeder mounted or on a bench top using the CALIBRATION knob.
Technical Support and Contact Information
Contact Maguire Products Inc. at 11 Crozerville Road, Aston, PA, or visit www.maguire.com for assistance.
Specifications and Setup
Plug the SIGNAL cord into a standard outlet and switch from OFF to CYCLE to initiate a cycle of 100 counts. Run calibration cycles to stabilize the metering rate, recording the gram weight metered each cycle.
Controller Operation
The MAGUIRE Digital Controller ensures precise speed regulation and metering control. It divides each full motor rotation into 159 increments, with a digital counter predetermining the rotation degree.
Regrind Feeder Integration
The MAGUIRE Color Feeders can integrate with a REGRIND Feeder to adjust color metering when regrind is added, preventing double coloring.
Concentrate Feeder Operation
The MAGUIRE CONCENTRATE AUGER FEEDER meters precise color concentrate quantities. It features a removable hopper for easy color changes and cleaning.
Powder Feeder Option
An optional powder feeder is available for materials prone to bridging, featuring a special hopper with an agitator.
Controls Description
  • CYCLE-OFF-CONTINUOUS SWITCH: Controls metering cycle and motor speed.
  • MOTOR FORWARD/REVERSE SWITCH: Allows reverse operation to verify metered color quantity.
  • THUMBWHEEL SWITCHES: Control color metering per cycle or motor speed in continuous mode.
  • MODE SWITCH: Offers special functions like fractional metering and calibration.
  • DIGITAL DISPLAY WINDOW: Displays countdown or motor speed.
  • SIGNAL LIGHT: Indicates power presence at the signal cord.
  • MOTOR LIGHT: Indicates motor operation.
Changing Colors
To change colors, remove the vacuum pickup line, unlock and slide back the controller-drive unit, remove and empty the hopper, clean the auger and hopper, and reassemble with the new color.
Troubleshooting Controller Problems
Guidance is provided for addressing issues with controllers, including reading about normal operation and documenting unresolved issues for repair.
Specifications for Output Problems
Details for injection molding and extrusion specifications are provided, advising users to check tube sizes and liquid color viscosity.
Electronic Failure Troubleshooting
Instructions for diagnosing electronic failures include checking voltage conditions and testing results.
Erratic or Incorrect Operation
Addresses issues with cycle settings, screw return times, and display behavior, advising users to check signal and motor lights.
In-House Repairs
Guidelines for inspecting internal electronics and cable connections are provided, with a caution against repairing printed circuit boards.
Troubleshooting Loss of Color
Users are instructed to verify color supply and auger rotation, with specific counts per auger turn provided for different models.
Maximum Output Specifications
Specifications for various models include auger size, RPMs, and metering rates, with recommendations for model selection based on extrusion rates.
MCF Features
Features include stainless steel construction, low profile adaptors, removable hoppers, and clear viewing windows.
Warranty Information
Maguire Products offers a five-year warranty covering defects in material and workmanship, limited to factory repairs.
Technical Support and Contact Information
Contact details for Maguire Products in the USA, Europe, and Asia are provided for technical support.
See more

Catalog excerpts

MCF Concentrate Auger Feeder-1

Concentrate Auger Feeder with Automatic Speed Control and Removable Hopper INSTRUCTION MANUAL Copyright © Maguire Products, Inc. 2013

 Open the catalog to page 1
MCF Concentrate Auger Feeder-3

Maguire Products Inc. Model MCF CONCENTRATE AUGER FEEDER with AUTOMATIC SPEED CONTROL Table of Contents Assembly and Installation Instructions __________________________ 5 Startup Instructions__________________________________________ 7 Normal Operation____________________________________________ 8 Formulas for Setting the Counter______________________________ 10 Determining Metering Rate ___________________________________ 11 Principle of Controller Operation ______________________________ 12 Controller Operation in Conjunction with Regrind Feeder _________ 13 Principle of Operation – Mechanical...

 Open the catalog to page 3
MCF Concentrate Auger Feeder-4

Copyright © 2010 Maguire Products Inc. The information contained within this manual including any translations thereof, is the property of Maguire Products Inc. and may not be reproduced, or transmitted in any form or by any means without the express written consent of Maguire Products Inc. To every person concerned with use and maintenance of the Model MCF Concentrate Auger Feeder with Automatic Speed Control it is recommended to read thoroughly these operating instructions. Maguire Products Inc. accepts no responsibility or liability for damage or malfunction of the equipment arising from non-observance...

 Open the catalog to page 4
MCF Concentrate Auger Feeder-5

ASSEMBLY AND INSTALLATION INSTRUCTIONS Your unit consists of 4 separate assemblies: 1. 2. 3. 4. The ADAPTOR frame assembly; 10" square, painted black. The SLIDE assembly; stainless steel. The HOPPER assembly; with feed auger. The CONTROLLER / Drive unit. 1. A locking latch is located on each side of the SLIDE assembly. Lift these latches up and rotate them forward until they fall freely. Grasp the heavy steel cross bar in one hand and with your other hand slide the motor mount frame straight back until it stops (5 inches). Lift the HOPPER assembly up and out and put aside. 2. Bolt the CONTROLLER...

 Open the catalog to page 5
MCF Concentrate Auger Feeder-6

CONCENTRATE FEEDER ASSEMBLY PICTURE

 Open the catalog to page 6
MCF Concentrate Auger Feeder-7

START UP PROCEDURE 1. Plug the "CONTINUOUS POWER" (black) cord into a standard 120-volt continuous power source. 2. Plug the "SIGNAL" (gray) cord into outlet that is energized only when the screw is turning. This SIGNAL outlet will provide a voltage signal to an internal electronic relay. Signal voltages from 18 to 250 can be handled. For more information about the signal that you must provide, see "SIGNAL SPECS", below. The main switch should now be set on "CYCLE". The "screw return", or "SIGNAL ON" time, must be at least one (1) second. If you are not sure that this is always the case, then...

 Open the catalog to page 7
MCF Concentrate Auger Feeder-8

NORMAL OPERATION The following is what to expect during normal operation. With MAIN POWER cord plugged in, NO power to the SIGNAL cord, Switch on CYCLE: The display should read zero ( 0) The motor light and signal lights are OFF The motor is NOT running. IN CYCLE: Nothing will run until the SIGNAL cord gets power. When the signal cord is powered, the signal light will be lit. The first time the signal cord gets power, the unit will start running at about 10 rpms and will count down starting from the number set on the counter. When the count reaches zero ( 0), the motor will stop. On all successive...

 Open the catalog to page 8
MCF Concentrate Auger Feeder-9

CYCLE TIME: The motor will start to run about 1/3 (.3) second after a signal is received. If the Signal is less than about 2/3 (.6) seconds long, then the motor will stop and the processor will NOT consider this as a valid cycle. No recalculation of motor speed will occur. If the signal is over 2/3 (.6) seconds long, then the motor will run for at least 2 seconds even if the signal goes away. This allows time for speed adjustments to occur. On longer cycles, over 2 seconds, the counter should count down to zero and the motor should stop within the 1/2 second before the end of the signal. If you...

 Open the catalog to page 9
MCF Concentrate Auger Feeder-10

FORMULAS FOR SETTING THE COUNTER CONCENTRATE FEEDER INJECTION MOLDING (Cycle Mode): 1. Determine the WEIGHT of the entire shot IN GRAMS. This is the combined weight of the part or parts plus the runner, if any, that is molded each cycle. 2. Determine the POUNDS per 100 of color required. This is the pounds of color that you use for each 100 pounds of natural material used. 3. Determine the METERING RATE for each color in grams/100 counts. Metering rate is the weight in grams of color that is metered when the counter is set to 100. See the next page for instructions on determining Metering Rates....

 Open the catalog to page 10
MCF Concentrate Auger Feeder-11

DETERMINING METERING RATE Different colors have different bulk densities and different flow characteristics. To compensate for these variations and insure ACCURACY, a METERING RATE must be determined for EACH COLOR. 1. You may use a feeder mounted on a machine or you may remove it from its mounting frame and set it on a bench top. You may use one feeder to determine metering rate and apply this information to all feeders that are the same model, (i.e. same auger size and same gearbox drive motor). 2. Have the black power cord plugged in. The process machine does not have to run. The Gray Cycle...

 Open the catalog to page 11
MCF Concentrate Auger Feeder-12

PRINCIPLE OF CONTROLLER OPERATION The MAGUIRE Digital Controller provides the precise speed regulation and metering control necessary to assure absolute accuracy over color usage. The Controller signal cord is plugged into an outlet that is energized only when the process machine screw runs. During each screw return cycle, the motor runs and color is metered into the throat of the process machine. Since metering rate is directly related to motor output shaft rotation, accuracy is obtained by controlling the exact degree of rotation of the drive motor. The unique Maguire Products Digital Controller...

 Open the catalog to page 12
MCF Concentrate Auger Feeder-13

CONTROLLER OPERATION IN CONJUNCTION WITH OUR REGRIND FEEDER All MAGUIRE Color Feeders are designed to work in conjunction with our REGRIND Feeder which may be purchased separately at some later date if the handling of REGRIND at-the-throat becomes a concern. This Regrind Feeder would be installed on the process machine at the base of the material hopper just above the throat. When used with our CONCENTRATE COLOR Feeder, the REGRIND Feeder adaptor frame would be mounted directly on top of our COLOR Feeder adaptor frame. The regrind would then enter the flow of virgin resin at the same height above...

 Open the catalog to page 13