Group: AMETEK
Catalog excerpts
TUFFY® T3Side Mounting Level Controls Tuffy liquid level switches are float actuated devices designed for horizontal mounting in a tank or vessel through threaded or flanged pipe connections. The compact size allows for installation in small vessels, while its many features provide a variety of application uses. The single switch mechanism is available in SPDT or DPDT forms on units designed for adjustable, narrow or wide differential and interface service. FEATURES * Maximum Process temperature: +400 °C (750 °F). Minimum Process temperature: -55 °C (-65 °F). * Maximum process Pressure: 150 bar abs (2160 psi). * Specific gravities as low as 0.4. * Wetted parts in 316/316L (1.4401/1.4404) or Hastelloy C (2.4819). * Available as: - Flanged - Threaded - Flanged or sealed cage mounted. ® Consult factory for proper partnumbers MODELS * Narrow differential switch (for alarm functions) - standard pressure (up to 50 bar abs (720 psi) - high pressure (up to 150 bar (2160 psi). * Wide adjustable differential switch (for control functions) * Interface switch (detection of interface level between liquids). * External cages. * Compact versions: - pneumatic narrow differential switch - electric narrow differential switch. APPLICATIONS * Sour service (NACE). * High/low alarm. * Single pump control. * Day storage tanks. * Corrosive processes. * Process vessels. * Boiler low water cut off. * Interface level. * Dirty process high level w/offset. * Installations in hazardous area. AGENCY APPROVALS
Open the catalog to page 1SWITCH MECHANISMS All TUFFY® are available with a selection of switch modules that vary in switch rating (Amp) and max process temperature allowance. The max temperature is dependent upon the housing material selected. Consult table below, before selecting the proper module in the order number structure on pages 3, 5, 7 or 9.
Open the catalog to page 2The Tuffy achieves switching action through the use of a magnetic switch mechanism and a magnet attached to the float assembly. Separating the two magnets is a non-magnetic pressure barrier. As the liquid level changes, the float, and therefore the float magnet, moves. The float and switch magnets repel each other causing movement of the switch mechanism, tripping the switch and making or breaking an electrical circuit. Float Magnet Non-magnetic Float holder (pressure boundary) Switch Magnet SELECTION DATA Narrow Differential: Wide Differential: Interface Service: Single Liquid: Adjustable...
Open the catalog to page 3T31 AND T35: THREADED NARROW DIFFERENTIAL DIMENSIONS in mm (inches) ORDER CODE Process connection: 2" NPT Max temperature: switch selection dependant – see table on page 2 Max pressure: 50 bar abs. (720 psi) / 103 bar abs. (1500 psi) Level Differential: 13 mm (0,5") T 3 1 - 0 0 2 N T 3 5 - 0 0 2 N Threaded Tuffy with 316/316L (1.4401/1.4404) float - min. S.G. 0,4 / max 50 bar abs. ( 720 psi) Threaded Tuffy with 316/316L (1.4401/1.4404) float - min. S.G. 0,6 / max 103 bar abs. (1500 psi) DESIGN CODE (All wetted parts in 316/316L (1.4401/1.4404)) Standard design ANSI/ASME B31.3 design NACE...
Open the catalog to page 4ORDER CODE Process connection: up to 600 lbs ANSI / PN 63 flanges Max temperature: switch selection dependant - see table on page 2 Max pressure: 50 bar abs. (720 psi) /103 bar abs (1500 psi), or limited to flange rating. Level Differential: 13 mm (0.5")
Open the catalog to page 5ORDER CODE Process connection: up to 900 lbs ANSI / PN 160 flanges Max temperature: switch selection dependant - see table on page 2 Max pressure: 150 bar abs. (2160 psi) Level differential: 13 mm (0,5") Flanged Tuffy with 316/316L (1.4401/1.4404) float - min. S.G. 0,6 / max 150 bar abs. (2160 psi) PROCESS CONNECTION - EN/DIN Flanges complete order code for flanged high pressure TUFFY®
Open the catalog to page 6Process connection: up to 300 lbs ANSI / PN 40 flanges Max temperature: switch selection dependant - see table on page 2 Max pressure: 50 bar abs. (720 psi) Level Differential: adjustable from 35 mm (1.36") to 464 mm (18.26") T 3 C Adjustable diff. Tuffy with 316/316L (1.4401/1.4404) float - min. S.G. 0,78 / max 50 bar abs. (720 psi) STEM EXTENSION LENGTH - DIMENSION "A" PROCESS CONNECTION - ANSI Flanges PROCESS CONNECTION - EN/DIN Flanges DESIGN CODE AND FLANGE MATERIAL
Open the catalog to page 7ORDER CODE Process connection: up to 300 lbs ANSI / PN 40 flanges Max temperature: switch selection dependant - see table on page 2 Max pressure: 50 bar abs. (720 psi) Min S.G. of lower liquid: 0,81 kg/dm3 Min S.G. difference between both liquids: 0,1 kg/dm3 Level differential: 44 mm (1.72") Interface Tuffy with 316/316L (1.4401/1.4404) float - max 50 bar abs. (720 psi)
Open the catalog to page 8039: PNEUMATIC COMPACT TUFFY (Narrow differential) DIMENSIONS in mm (inches) SP. GR. 0.4 min – 226 (8.91) Float size = 51 ø x 130 long (2.00 x 5.12) SP. GR. 0.6 min – 202 (7.96) Float size = 51 ø x 116 long (2.00 x 4.57) 1/4" NPT inlet connection standard (B) 1/4" NPT inlet connection standard (A) NPT outlet connection standard (C) Switch actuates rising level Switch actuates falling level float minimum clearance 95 (3.75) ORDER CODE Process connection: 2" NPT Max temperature: 150 °C (300 °F) @ 103 bar (1500 psi) - S.G: 0,6 and 34 bar (500 psi) - S.G: 0,4 Max pressure: 103 bar (S.G: 0,6), 34...
Open the catalog to page 9CAGE - STYLE Flanged type 035 cage Sealed type 033 cage chamber flange CAGE - PROCESS CONNECTION
Open the catalog to page 10ORDER CODE complete order code for external cage
Open the catalog to page 11QUALITY ASSURANCE - ISO 9001:2000 THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE DESIGN, THE CONSTRUCTION AND THE SERVICE OF CONTROLS. OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001:2000 AND OUR TOTAL COMPANY IS COMMITTED TO PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE. PRODUCT WARRANTY ALL MAGNETROL MECHANICAL LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR FIVE FULL YEARS FROM THE DATE OF ORIGINAL FACTORY SHIPMENT. IF RETURNED WITHIN THE WARRANTY...
Open the catalog to page 12All Magnetrol - AMETEK catalogs and technical brochures
-
Interface In The Field
14 Pages
-
Emulsion In The Field
9 Pages
-
PRODUCT LINE CATALOGUE
106 Pages
-
Aurora® Magnetic Level Indicator
28 Pages
-
Atlas™ Magnetic Level Indicator
24 Pages
-
STEAM DRUM LEVEL MATTERS
1 Pages
-
INTERFACE IN THE FIELD
1 Pages
-
Echotel® 355
4 Pages
-
Echotel® 335
4 Pages
-
Power Generation
16 Pages
-
Petroleum Refining
16 Pages
-
Natural Gas Processing
12 Pages
-
Seal Pots
4 Pages
-
Mass Flow Measurement
12 Pages
-
Interface Level Measurement
8 Pages
-
Heat Rate Awareness
8 Pages
-
Ethylene Applications
8 Pages
-
Thermatel® TD1/TD2
16 Pages
-
Kotron® 082
4 Pages
-
Enhanced Jupiter®
16 Pages
-
GEMINI™
32 Pages
-
Aurora®
32 Pages
-
Atlas™
24 Pages
-
Horizon TM Model 704
8 Pages
-
Eclipse® Enhanced 705 Hygienic
12 Pages
-
Eclipse® Enhanced 705
8 Pages
-
Models T5x & T6x
8 Pages
-
Models T20/T21
12 Pages
-
Series B73 and Series 75
12 Pages
-
Series 3
24 Pages
-
Model J52
2 Pages
-
Model B40
4 Pages
-
TUFFY® II
12 Pages
-
Digital E3 Modulevel®
12 Pages
-
Floating Roof Detection
16 Pages
-
APM Pneumatic Modulevel®
12 Pages
-
Flue Gas Desulferization
8 Pages
-
Energy Management
4 Pages
-
API 2350 Overfill Prevention
8 Pages
-
PULSAR ® R96
1 Pages
-
Water & Wastewater
12 Pages
-
Displacer Switches
20 Pages
-
Displacer Transmitters
4 Pages
-
Guided Wave Radar
12 Pages
-
Magnetic Level Indicators
12 Pages
-
Magnetostrictive
16 Pages
-
Pulse Burst Radar
8 Pages
-
Thermal Dispersion
12 Pages
-
Ultrasonic Contact
4 Pages
-
Vibrating Rod Switches
4 Pages
-
R Series High Temp Switch
12 Pages
-
Series K Pneumatic Switch
8 Pages
-
J Series Pneumatic Switch
8 Pages
-
Liquid Displacer Level Switches
16 Pages
-
Crude Oil Processing
8 Pages
-
Product Line Quick Reference
8 Pages