C24, C25, Boiler and Water Column Liquid Level Switches
8Pages

{{requestButtons}}

Catalog excerpts

C24, C25, Boiler and Water Column Liquid Level Switches - 1

C24, C25, Boiler and Water Column Liquid Level Switches DESCRIPTION C24, C25, Boiler and Water Column Liquid Level Switches are single or multi-switch units that offer versatility and reliable operation in a variety of applications. Available with up to three switch mechanisms for level alarm, control, and shutdown functions, the boiler and water column controls are designed for use in steam boiler applications while the Models C24 & C25 are for general industrial use. FEATURES • Easy inspection of float chamber through removable head • Cast iron or fabricated steel float chambers • 316 and 316L stainless steel floats • Brass chamber liner standard in B24, B25, W24, and W25 models • Right or left hand water column mounting • Try cock tappings and sight glass tappings available • Process temperature to +1000° F (+538° C) • Multiple switch capability • Working steam pressure to 600 pounds • Choice of switch mechanisms: Pneumatic Hermetically sealed Dry contact • Choice of switch mechanism enclosures: APPLICATIONS • Condensate receiver control • Flash tank high level alarm • Water tube boiler low water cutoff NEMA 1 carbon steel for pneumatic • Boiler steam chest high level alarm TYPE 4X/7/9 Class I, Div. 1, Groups C & D, polymer coated aluminum • Boiler feedwater pump control • Day tanks TYPE 4X/7/9 Class I, Div. 1, Group B, polymer coated aluminum • Optional high temperature insulation available. See bulletin 41-106. • Boiler low water cutoff • Holding tanks

Open the catalog to page 1
C24, C25, Boiler and Water Column Liquid Level Switches - 2

TECHNOLOGY A permanent magnet ➀ is attached to a pivoted switch actuator and adjustment screw ➁. As the float ➂ rises following the liquid level, it raises the attraction sleeve ➃ into the field of the magnet, which then snaps against the non-magnetic enclosing tube ➄, actuating the switch ≈. The enclosing tube provides a static pressure boundary between the switch mechanism and the process. On a falling level, an inconel spring retracts the magnet, deactivating the switch. MOUNTING WATER The right- and left-hand mounting arrangement refers to the position of the try cock tappings in...

Open the catalog to page 2
C24, C25, Boiler and Water Column Liquid Level Switches - 3

SPECIFICATIONS SWITCH SERIES B, C & D DRY CONTACT SWITCHES SERIES F, HS, 8 & 9 HERMETICALLY SEALED SWITCHES • Dry contact for applications where mercury must be avoided • Ideal for use in salt and other corrosive atmospheres • Designs for AC and DC current applications • HS is a positively pressurized capsule for entire mechanism and contacts SERIES J & K PNEUMATIC SWITCHES SWITCH ENCLOSURES • Suited for applications where electrical power is not available • TYPE 4X/7/9 aluminum enclosures • Designed to meet Class I, Div. 1, Groups C & D and Class I, Div. 1 Group B • Bleed and non-bleed...

Open the catalog to page 3
C24, C25, Boiler and Water Column Liquid Level Switches - 4

APPRoVeD MoDeL APPRoVAL CLASSeS All with an electric switch mechanism and a housing listed as TYPE 4X/7/9 Class I, Div 1, Groups C & D Class II, Div 1, Groups E, F & G All with an electric switch mechanism and a housing listed as TYPE 4X/7/9 Class I, Div 1, Group B Class I, Div 1, Groups B, C & D Class II, Div 1, Groups E, F & G All with a Series HS, F, 8 or 9 electric switch mechanism and a housing listed as CSA TYPE 4X All with an electric switch mechanism and a housing listed as TYPE 4X/7/9 Class I, Div 1, Groups C & D Class II, Div 1, Groups E, F & G All with an electric switch...

Open the catalog to page 4
C24, C25, Boiler and Water Column Liquid Level Switches - 5

DIMENSIONAL INCHES Gauge glass L tappings Low water cutoff point Allow 10.00 (254) overhead clearance for cover removal. ACTUATION LEVELS * Electrical Switches: TYPE 4X/7/9: 1" NPT Group B: 1" NPT Pneumatic Switches: 1 NEMA 1: ⁄4" NPT * Single switch mechanism only. Consult factory for multiple switches. Levels are ±0.25" (6 mm) DIMENSIONS Model

Open the catalog to page 5
C24, C25, Boiler and Water Column Liquid Level Switches - 6

NUMBER Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP) MODEL NUMBER CODE, MATERIALS OF CONSTRUCTION AND TANK CONNECTION Model Code Chamber Material Attraction Sleeve Float Material Trim Material Fabricated Steel Right Hand Left Hand ELECTRIC SWITCH MECHANISM AND ENCLOSURE ➆ (Additional models on next page) Switch Description Series B Snap Switch TyPe 4X/7/9 Aluminum enclosure ≈ Class I, Div. 1, groups C & D Series F Hermetically Sealed Snap Switch Series C Snap Switch PNEUMATIC SWITCH...

Open the catalog to page 6
C24, C25, Boiler and Water Column Liquid Level Switches - 7

ELECTRIC SWITCH MECHANISM AND ENCLOSURE Switch ➄ Description Series B Snap Switch Series C Snap Switch Series D DC Current Snap Switch Series F Hermetically Sealed Snap Switch Series HS Hermetically Sealed 5-amp Snap Switch with Wiring Leads Series HS Hermetically Sealed 5-amp Snap Switch with Terminal Block All models except Model C25-2B10 only B24, C24 and C25-2B10 Process ➃ Temperature Set TyPe 4X/7/9 Aluminum enclosure Contacts Range Points ATEX ATEX Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 °F (°C) Ex II 2 G EEx Ex II 2 G EEx Groups C&D Group B Groups C&D Group B d...

Open the catalog to page 7
C24, C25, Boiler and Water Column Liquid Level Switches - 8

QUALITY The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. Magnetrol is committed to providing full customer satisfaction both in quality products and quality service. The Magnetrol quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product/service quality available. Several Level Switches are available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship...

Open the catalog to page 8

All Magnetrol - AMETEK catalogs and technical brochures

  1. Seal Pots

    4 Pages

  2. Kotron® 082

    4 Pages

  3. GEMINI™

    32 Pages

  4. Aurora®

    32 Pages

  5. Atlas™

    24 Pages

  6. Models T20/T21

    12 Pages

  7. Series 3

    24 Pages

  8. Model J52

    2 Pages

  9. Model B40

    4 Pages

  10. TUFFY® II

    12 Pages