1. Catalogs
  2. Magnetrol - AMETEK
  3. TOP MOUNTING Liquid Displacer Level Switches

TOP MOUNTING Liquid Displacer Level Switches

TOP MOUNTING Liquid Displacer Level Switches
1 / 20 PagesView full catalog

TOP MOUNTING Liquid Displacer Level Switches

Product catalog summary
Description: Magnetrol's displacement type level switches are designed for industrial applications, offering various alarm and control configurations. They operate on a buoyancy principle, suitable for both simple and complex applications, including foaming or surging liquids, and are cost-effective compared to other level switches.
Features:
  • Adjustable narrow or wide level ranges with multiple switch mechanisms.
  • Maximum process temperature of +260 °C (500 °F) and pressure of 55.1 bar (800 psi).
  • Suitable for specific gravities as low as 0.4 kg/dm³.
  • Displacers can be adjusted along the suspension cable.
  • Anti-surge design to prevent switch short cycling.
  • Standard 3 m (10 ft) suspension cable included.
  • Field adjustable set point and switch differential.
  • Variety of displacer materials and housings available.
  • Standard anti-corrosive protection and optional high temperature, high pressure, and special exterior finishes.
Applications: Suitable for foaming or surging liquids, paints, varnishes, sewage handling, heavy oils, dirty liquids, and liquids with solids.
Principle of Operation: The operation is based on buoyancy, where weighted displacers immersed in liquid cause a buoyancy force change, moving a spring and actuating a switch mechanism through a magnetic sleeve and pivoted magnet system.
Proof-er® Controls: Allows checking of displacer control operation without raising tank levels by simulating high-level conditions through a cable mechanism.
Floating Roof Controls: Designed for barrier tanks, with options for brass or stainless steel displacers to prevent sparking.
Agency Approvals: Models are approved under various standards including ATEX, FM, IECEx, CSA, and EAC, conforming to directives like ATEX 2014/34/EU and PED 2014/68/EU.
Switch Models:
  • Single, dual, and triple switch models available with narrow or wide differential types for alarms and pump controls.
  • Models A10 and A15 are factory calibrated for specific applications, with adjustable differential bands.
Switch Mechanisms and Housings:
  • Various series of switches available, including hermetically sealed, inductive proximity, pneumatic, and dry contact switches.
  • Switch housings available in die-cast aluminum, cast iron, and stainless steel, with optional heaters and drains.
Selection Data: Detailed specifications for selecting the appropriate switch mechanism and housing based on application requirements, including temperature ranges and contact types.
Flange Specifications: ASME and EN flanges are specified with various sizes and pressure ratings. ASME flanges range from 3" to 6" with pressure ratings of 150 lbs and 300 lbs. EN flanges are specified for DN 80 and DN 100 with pressure ratings of PN 16 and PN 25/40.
Selection Data for Dual Switch Floating Roof Model: Materials used include Inconel 600, 316 SST, carbon steel, and 400 series SST. The construction is standard across different codes.
Electric Switch Mechanism and Housing: Various series of snap switches are available, each with different temperature ranges and contact types. The switches are weatherproof and suitable for hazardous areas, with options for hermetically sealed and gold or silver plated contacts.
Physical and Electrical Specifications: The measured variable is liquid level with a standard cable length of 3 m. Process temperature and pressure specifications vary based on the displacer material and connection type. Switch ratings are up to 15 A at 240 V AC and 10 A at 120 V DC.
Dimensions: Dimensions for housings and displacers are provided in mm and inches. Models A10/A15/B10/B15 and C10/C15 have specific dimensions for threaded and flanged mountings.
Quality Assurance and Warranty: The quality assurance system is ISO 9001 certified, ensuring high-quality design, construction, and service. A 3-year warranty covers defects in materials and workmanship, with certain exclusions.
Contact Information: European Headquarters & Manufacturing Facility is located in Zele, Belgium, with contact details provided for further inquiries.
See more

Catalog excerpts

TOP MOUNTING Liquid Displacer Level Switches-1

/ AMETEK LEVEL MEASUREMENT SOLUTIONS Magnetrol's displacement type level switches offer the industrial user a wide choice of alarm and control configurations. Each unit utilizes a simple buoyancy principle and is well suited for simple or complex applications, such as foaming or surging liquids or agitated fluids, and usually costs less than other types of level switches. • Narrow or wide level ranges achieved through multiple switch mechanism capability • Maximum process temperature: +260 °C (500 °F). • Maximum process pressure: 55,1 bar (800 psi). • Displacers adjustable at any point along the suspension cable. • Anti-surge design eliminates the possibility of switch short cycling. • Standard 3 m (10 ft) of suspension cable, included for all models. • Field adjustable set point and switch differential. • Wide choice of displacer materials. • Wide choice of housings and switch mechanisms • Standard anti-corrosive protection. • Proof-er® ground check • Floating roof models • NACE construction - high temperature models - high pressure models - special exterior surface preparation and finish. • Foaming or surging liquids • Paints • Agitated fluids • Varnishes • Sewage handling • Heavy oils • Dirty liquids • Liquids with solids

 Open the catalog to page 1
TOP MOUNTING Liquid Displacer Level Switches-2

Standard controls Operation is based upon simple buoyancy, whereby a spring is loaded with weighted displacers which are heavier than the liquid. Immersion of the displacers in the liquid results in buoyancy force change, which moves the spring upward. Since the spring moves only when the level moves on a displacer, spring movement (1) is always a small fraction of the level travel between displacers (2). A magnetic sleeve (3) is connected to the spring and operates within a non-magnetic barrier tube (4). Spring movement causes the magnetic sleeve to attract a pivoted magnet (5), actuating a...

 Open the catalog to page 2
TOP MOUNTING Liquid Displacer Level Switches-3

AGENCY APPROVALS AGENCY APPROVED MODEL AREA CLASSIFICATION All with electric switch mechanism and housing listed as ATEX Ex d All with electric switch mechanism and housing listed as ATEX Ex ia All with electric switch mechanism and housing listed as NEMA 7/9 Class I, Div 1, groups C & D Class II, Div 1, Groups E, F & G Consult factory for proper model numbers Class I, Div 1, groups B, C & D Class II, Div 1, Groups E, F & G All with electric switch mechanism and housing listed as IECEx Ex d All with electric switch mechanism and housing listed as IECEx Ex ia Consult factory for proper model numbers...

 Open the catalog to page 3
TOP MOUNTING Liquid Displacer Level Switches-4

Models A15 -Level alarm applications Narrow differential type These instruments are factory calibrated to operate over a narrow level differential band and are ideally suited for liquid level alarm applications, on either high or low level. The operating level is fully adjustable by simply repositioning the displacer along its suspension cable. The differential band is ± 51 mm (2") in water and varies with liquid specific gravity. Models A10 -Pump or valve control Wide differential type These wide differential units are factory calibrated to actuate as a liquid level reaches a given displacer...

 Open the catalog to page 4
TOP MOUNTING Liquid Displacer Level Switches-5

Series B, C, D, O, Q & U Dry contact switches ® • Series B, C, O and Q switches are general purpose units with a selection of maximum liquid temperature ratings • Series D switch is designed for high DC current applications • Series U switches have gold alloy contacts Series J & K Pneumatic switches ® • Suited for process industry applications in hazardous locations or where electrical power is not available • Series J bleed type switch is intended for general purpose applications • Series K switch is specially designed to provide nonbleed operation with a high degree of vibration resistance...

 Open the catalog to page 5
TOP MOUNTING Liquid Displacer Level Switches-6

Order code for standard models (each unit is factory calibrated to operate on a given specific gravity within the min and the max values listed per model) 1 - 3 I PART NUMBER CODE AND SPECIFIC GRAVITY LIMITS complete order code for standard models X = product with a specific customer requirement

 Open the catalog to page 6
TOP MOUNTING Liquid Displacer Level Switches-7

SELECT ELECTRIC SWITCH MECHANISM & HOUSING: MODEL A15 © Process temperature based on max. 40 °C (100 °F) ambient temperature and for non steam applications. © On steam applications, temperature down-rated to +200 °C (+400 °F) process at +40 °C (+100 °F) ambient.

 Open the catalog to page 7
TOP MOUNTING Liquid Displacer Level Switches-8

Order code for standard models (each unit is factory calibrated to operate on a given specific gravity within the min and the max values listed per model) 1 - 3 I PART NUMBER CODE AND SPECIFIC GRAVITY LIMITS complete order code for standard models X = product with a specific customer requirement

 Open the catalog to page 8
TOP MOUNTING Liquid Displacer Level Switches-9

SELECT ELECTRIC SWITCH MECHANISM AND HOUSING: MODELS B10 & B15 © Process temperature based on max. 40 °C (100 °F) ambient temperature and for non steam applications. OPERATING SEQUENCES Model B10 units are available factory calibrated with a choice of switch operating sequence. Five of the most popular sequences are described below. cmD—cn> -cm—tnrn> ccmed — Top switch, narrow differential fixed _ Bottom switch, wide Bottom switch, narrow differential fixed When ordering B10 units, an operating sequence and specific gravity must be provided. PUMP CONTROL PLUS ALARM Arrangement N° 1 — fill with...

 Open the catalog to page 9
TOP MOUNTING Liquid Displacer Level Switches-10

Note: Each C10 and C15 instrument is factory calibrated to operate for a given specific gravity within the minimum and maximum values listed. 1 - 3 I PART NUMBER CODE AND SPECIFIC GRAVITY LIMITS —► X = product with a specific customer requirement complete order code for standard models 10

 Open the catalog to page 10
TOP MOUNTING Liquid Displacer Level Switches-11

OPERATING SEQUENCES When ordering C15 units, a specific gravity MUST be provided. Upper switch narrow diff. fixed Middle switch narrow diff. fixed Lower switch narrow diff. fixed Model C10 units are available factory calibrated with a choice of switch operating sequence. Seven of the most popular sequences are described below. Upper switch wide diff. adjustable Middle switch wide diff. adjustable Lower switch wide diff. adjustable Upper switch wide diff. adjustable Middle switch wide diff. adjustable Lower switch wide diff. adjustable Lower switch narrow diff. fixed Lower switch wide diff. adj. Middle...

 Open the catalog to page 11

Archived catalogs

  1. Model B40

    12  Pages

  2. Model J52

    2  Pages

  3. Series 3

    24  Pages

  4. Models T20/T21

    12  Pages

  5. GEMINI™

    20  Pages

  6. Seal Pots

    4  Pages

  7. Echotel® 355

    8  Pages

  8. E4 Modulevel®

    12  Pages

  9. TUFFY® II

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.