
/ AMETEK LEVEL MEASUREMENT SOLUTIONS Float level switches for single or dual level alarm DESCRIPTION T20 and T21 units are simple, reliable float switches designed for top mounting into tanks or vessels. T20 units utilize a single switch mechanism and float. T21 units utilize two switch mechanisms and two separate floats when widely spaced actuating levels are required. T20 and T21 models are available for any type of open or closed vessel with either threaded or flanged type mounting and actuating depths up to 1219 mm (48 inches). FEATURES • Carbon or stainless steel process connection materials (other materials available at request) • Flanged and threaded process connections • Wide choice of housings and switch mechanisms • Standard anti corrosive protection • Custom calibrated - NACE construction - Interface calibration - Special tank connections - Elevated temperature - Special exterior surface preparation and finish - Stilling well - Tropicalized switch mechanism - Submersible housing • Condensate Receivers • Fuel Storage Tanks • Cooling Towers • Flash Tanks • High and high/high alarm from single tan
Open the catalog to page 1PRINCIPLE OF OPERATION A permanent magnet ➀ is attached to a pivoted switch actuator and adjustment screw ➁. As the float ➂ rises following the liquid level, it raises the attraction sleeve ➃ into the field of the magnet, which then snaps against the non-magnetic enclosing tube ➄, actuating the switch ≈. The enclosing tube provides a static pressure boundary between the switch mechanism and the process. On a falling level, an inconel spring retracts the magnet, deactivating the switch. process liquid process liquid rising level falling level T20 – SINGLE SWITCH MODEL T21 – DUAL SWITCH MODEL Level...
Open the catalog to page 2Other approvals are available, consult factory for more details
Open the catalog to page 3Series B, C, D, R & U Dry contact switches ® • Series B and C switches are general purpose units with a selection of maximum liquid temperature ratings • Series D switch is designed for high DC current applications • Series U switches have gold alloy contacts • Series R switches are designed for the highest temperature applications up to +540 °C (+1000 °F) • Suited for process industry applications in hazardous locations or where electrical power is not available • Series J bleed type switch is intended for general purpose applications • Series K switch is specially designed to provide nonbleed...
Open the catalog to page 4Note: On model T21, the lower float actuates the upper switch mechanism. The upper float actuates the lower switch mechanism. Housing type Allow 200 mm (7.87") overhead clearance / All housings are 360 ° rotatable
Open the catalog to page 5Order code for T20 models (each unit is factory calibrated to operate on a given specific gravity within the min and the max values listed per model) 1 - 4 I MODEL NUMBER CODE AND MATERIALS OF CONSTRUCTION complete order code for T20 models ■>- X = product with a specific customer requirement
Open the catalog to page 6® Process temperature based on max. 40 °C (100 °F) ambient temperature and for non steam applications. © On steam applications, temperature down-rated to +200 °C (+400 °F) process at +40 °C (+100 °F) ambient. © Upon prolonged exposure to temperatures above 425 °C (800 °F), the carbide phase of steel may be converted to graphite. Permissible but not recommended for prolonged use above 425 °C (800 °F). (Applies to models T20-A & T20-B.)
Open the catalog to page 7Order code for T21 models (each unit is factory calibrated to operate on a given specific gravity within the min and the max values listed per model) 1 - 4 I MODEL NUMBER CODE AND MATERIALS OF CONSTRUCTION ® Flanges are threaded onto 1" NPT bushing ® Float cannot pass S160 nozzle or greater | 9 - 10 I SWITCH MECHANISM & HOUSING (next page) —► X = product with a specific customer requirement
Open the catalog to page 8© Process temperature based on max. 40 °C (100 °F) ambient temperature and for non steam applications. © Upon prolonged exposure to temperatures above 425 °C (800 °F), the carbide phase of steel may be converted to graphite. Permissible but not recommended for prolonged use above 425 °C (800 °F). (Applies to models T20-A & T20-B.)
Open the catalog to page 9PHYSICAL SPECIFICATIONS ELECTRICAL CONNECTION
Open the catalog to page 10QUALITY ASSURANCE - ISO 9001 THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE DESIGN, THE CONSTRUCTION AND THE SERVICE OF CONTROLS. OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001 AND OUR TOTAL COMPANY IS COMMITTED TO PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE. PRODUCT WARRANTY ALL MAGNETROL MECHANICAL LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR 3 FULL YEARS FROM THE DATE OF ORIGINAL FACTORY SHIPMENT. IF RETURNED WITHIN THE WARRANTY PERIOD; AND, UPON...
Open the catalog to page 128 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
20 Pages
2 Pages
2 Pages
28 Pages
28 Pages
12 Pages
8 Pages
8 Pages
16 Pages
8 Pages
8 Pages
12 Pages
4 Pages
12 Pages
12 Pages
12 Pages
4 Pages
12 Pages
1 Page
8 Pages
4 Pages
8 Pages
12 Pages
20 Pages
16 Pages
12 Pages
2 Pages
24 Pages
12 Pages
12 Pages
12 Pages
20 Pages
8 Pages
8 Pages
12 Pages
4 Pages
16 Pages
16 Pages
1 Page
1 Page
8 Pages
28 Pages
28 Pages
106 Pages
9 Pages
14 Pages
12 Pages
8 Pages
16 Pages
12 Pages
12 Pages
12 Pages