Description
The Eclipse® Model 706 High Performance Transmitter is a 24 VDC loop-powered level transmitter using Guided Wave Radar (GWR) technology. It features diode switching technology and a comprehensive probe offering, suitable for applications ranging from light hydrocarbons to water-based media. The transmitter is designed for easy wiring, configuration, and viewing with its angled, dual compartment enclosure.
Applications
This transmitter is suitable for measuring liquids, solids, or slurries in most process or storage vessels. It can handle conditions with visible vapors, foam, surface agitation, and varying dielectric media.
Technology and Operation
The Eclipse Model 706 operates on Time Domain Reflectometry (TDR), using electromagnetic pulses transmitted down a waveguide. It measures liquid levels by detecting reflections from surfaces with higher dielectric constants, capable of measuring both upper and interface liquid levels.
Features
- Multivariable, two-wire transmitter for level, interface, volume, or flow.
- Compatible with Model 705 probes using a unique adapter.
- Diode switching technology for enhanced signal strength.
- No need for level movement during calibration.
- Overfill capable probes for accurate measurement up to the process seal.
- 4-button keypad and graphic LCD for configuration and diagnostics.
- Proactive diagnostics with troubleshooting tips.
- Supports various digital outputs including Foundation fieldbus™, PROFIBUS PA, and Modbus.
Special Applications
- Emulsion Layers: Detects the top of emulsion layers with measurement algorithms.
- Saturated Steam Applications: Compensates for vapor space dielectric changes using a mechanical steam target.
- Overfill Capability: Measures accurate levels up to the process flange without a non-measurable zone.
Probe Overview
Two styles of GWR probes are available: coaxial and single element (rigid rod or flexible cable). Coaxial probes are efficient and immune to proximity effects, suitable for clean liquids. Enlarged coaxial probes handle difficult liquids with higher viscosities. Caged GWR probes use existing cages for dirty liquids. Single rod probes operate differently, with energy efficiency related to the metallic surface at the top of the vessel.
Model 705/706 Adapter
The Model 706 transmitter can be used with legacy Model 705 probes using an adapter, providing performance advantages and diagnostics of the latest generation.
Probe Specifications
Details specifications for different probe models used for level/interface applications in tanks. Key materials include 316/316L, Hastelloy C, and Monel. Probes operate under specific temperature and pressure conditions, with a dielectric range of 1.7 to 100. Transition zones affect measurement accuracy, and vacuum service is possible with certain limitations.
Temperature/Pressure Ratings
Provides detailed charts for maximum pressure ratings across various temperatures for different probe materials (316/316L SST, Hastelloy C276, Monel 400).
O-Ring (Seal) Selection Chart
Lists specifications for various o-ring materials, including maximum and minimum process temperatures and pressures. Recommendations and limitations for each material are provided based on application suitability.
Replacement of Displacer Transmitters
Discusses the advantages of replacing torque tube transmitters with Eclipse Model 706 Guided Wave Radar transmitters, highlighting cost-effectiveness, ease of installation, and improved performance.
Overview
Provides technical specifications and guidelines for AMETEK LMS chambers and related equipment, focusing on their use with Guided Wave Radar (GWR) level transmitters.
Specifications
Lists various models of chambers and probes, specifying materials like carbon steel and stainless steel, and dimensions in both inches and millimeters.
Procedures
Installation guidelines emphasize preventing ignition risks due to impact or friction, minimizing electrostatic discharge, and ensuring proper temperature management to maintain safety codes.
Standards and Compliance
The equipment complies with several directives, including EMC-directive 2014/30/EU, PED-directive 2014/68/EU, and ATEX directive 2014/34/EU.
Recommendations
Advises on the use of factory pre-configured models for ease of installation and highlights the need for transient over-voltage protection.
Agency Approvals
The equipment is approved by multiple agencies, including FM, CSA, ATEX, IECEx, and InMetro.
Model Numbering
Detailed model numbering systems are provided for both enlarged and small coaxial probes, outlining options for technology, measurement systems, process connections, construction codes, and material specifications.
Specifications and Standards
Outlines various specifications for flanges and probes, referencing standards such as EN 1092-1 Type A and B2.
Mounting Considerations
Guidelines for mounting probes in tanks are provided, emphasizing the importance of avoiding turbulence and ensuring proper nozzle dimensions.
Aurora Chamber
The Aurora chamber combines a Guided Wave Radar transmitter with a Magnetic Level Indicator for redundancy.
Warranty and Quality Assurance
Includes warranty information, stating that AMETEK LMS products are warranted against defects for eighteen months.
See more

Catalog excerpts

Eclipse® Model 706 High Performance-1

Eclipse® Model 706 High Performance Guided Wave Radar Level Transmitter DESCRIPTION The Eclipse® Model 706 High Performance Transmitter is a loop-powered, 24 VDC level transmitter that is based upon the proven and accepted technology of Guided Wave Radar (GWR). Encompassing a number of significant engineering accomplishments, this leading edge level transmitter is designed to provide measurement performance well beyond that of many of the more traditional technologies. Utilizing patented “diode switching” technology, along with the most comprehensive probe offering on the market, this single transmitter can be used in a wide variety of applications ranging from very light hydrocarbons to water-based media. The innovative angled, dual compartment enclosure is now a common sight in the industry. This enclosure, first brought to the industry by Magnetrol® in 1998, is angled to maximize ease of wiring, configuration, and viewing of the versatile graphic LCD display. One universal Model 706 transmitter can be used and interchanged with all probe types, and offers enhanced reliability as it is certified for use in critical SIL 2 hardware safety loops. With the use of a unique adapter, the model 706 transmitter can even operate with older Model 705 probes. The Eclipse Model 706 supports both the FDT/DTM and Enhanced DD (EDDL) standards, which allow viewing of valuable configuration and diagnostic information such as the echo curve in tools such as PACTware™, AMS Device Manager, and various HART® Field Communicators. Measures Level, Interface, Volume, and Flow APPLICATIONS MEDIA: Liquids, solids, or slurries; hydrocarbons to water-based media (Dielectric Constant εr = 1.2–100) VESSELS: Most process or storage vessels up to rated probe temperature and pressure. CONDITIONS: All level measurement and control applications including process conditions exhibiting visible vapors, foam, surface agitation, bubbling or boiling, high fill/empty rates, low level and varying dielectric media or specif

 Open the catalog to page 1
Eclipse® Model 706 High Performance-2

FEATURES • Multivariable, two-wire, 24 VDC loop-powered transmitter for level, interface, volume, or flow. • 30-point custom strapping table for uncommonlyshaped tanks. • Unique adapter allows operation with Model 705 probes • Generic flow equation for non-standard channels. • Diode switching technology offers best-in-class signal strength and signal-to-noise ratio (SNR) resulting in enhanced capability in difficult low dielectric applications. • 360° rotatable housing can be separated from probe without depressurizing the vessel. • Probe designs up to +850 °F/6250 psi (+450 °C/ 431 bar). • Level...

 Open the catalog to page 2
Eclipse® Model 706 High Performance-3

SPECIAL APPLICATIONS EMULSION LAYERS As emulsion layers, also called “rag layers,” can decrease the strength of the reflected signal in an interface application, GWR transmitters are typically recommended for applications that have clean, distinct layers. However, the Eclipse Model 706, with its powerful internal measurement algorithms, will tend to detect the top of an emulsion layer. Contact the factory for application assistance regarding emulsion layers in your specific application. SATURATED STEAM APPLICATIONS (Boilers, Feedwater Heaters, etc.) As the temperature of a saturated steam application...

 Open the catalog to page 3
Eclipse® Model 706 High Performance-4

PROBE OVERVIEW TWO STYLES OF GWR PROBES With one basic Eclipse Model 706 transmitter that operates with all probes, choosing the proper Guided Wave Radar (GWR) probe is the most important decision in the application process. The probe configuration establishes fundamental performance characteristics. Both of these probe configurations has specific strengths and weaknesses. Although there can be overlap, and different probes can certainly be used in similar applications, it is important to understand their basic differences so that one can choose the probe type that will offer optimal performance....

 Open the catalog to page 4
Eclipse® Model 706 High Performance-5

PROBE OVERVIEW continued OPTIONAL FLUSHING CONNECTION The maintenance of coaxial GWR probes in applications suffering from buildup or crystallization can be significantly improved by using an optional flushing connection. This flushing connection is a metal extension with a port welded above the process connection. The port allows the user to purge the inside of the coaxial GWR probe during routine maintenance. Note: The best approach to eliminate the effects of condensation or crystallization is to install adequate insulation or heat tracing (steam or electrical). A flushing connection is no...

 Open the catalog to page 5
Eclipse® Model 706 High Performance-6

PROBE OVERVIEW continued SINGLE ROD PROBES Single element GWR probes operate quite differently from the coaxial design. With only one conductor to work with, the pulses of energy develop between the single rod probe and the mounting nut or flange. In other words, the pulse propagates down and around the rod as it references its ground at the top of the tank. The energy and efficiency of the pulse are directly related to how much metallic surface exists around it at the top of the vessel. This metallic surface at the top of the probe is called the “launch plate” The larger the launch plate, the...

 Open the catalog to page 6
Eclipse® Model 706 High Performance-7

signal propagation signal propagation © 2nd digit A=English, C=Metric © Minimum Sr 1.2 with end of probe analysis enabled. © Single rod probes mounted directly into the vessel must be within 3-6 inches of metal tank wall to obtain minimum dielectric of 1.4, otherwise Sr min = 1.7. © Depends on the probe spacer material. Refer to Model Selection for spacer options. © Eclipse probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seals are hermetically sealed to <10-8 cc/sec @ 1 atmosphere helium. © When installed in side-mounted chamber....

 Open the catalog to page 7
Eclipse® Model 706 High Performance-9

© Single rod probes must be used in metallic vessel or stillwell to maintain CE noise immunity © Specifications will degrade in Fixed Threshold mode. © Linearity in top 18 inches (46 cm) of single rod probes in tanks will be application dependent. © Accuracy may degrade when using manual or automatic compensation.

 Open the catalog to page 9

Archived catalogs

  1. Model B40

    12  Pages

  2. Model J52

    2  Pages

  3. Series 3

    24  Pages

  4. Models T20/T21

    12  Pages

  5. GEMINI™

    20  Pages

  6. Seal Pots

    4  Pages

  7. Echotel® 355

    8  Pages

  8. E4 Modulevel®

    12  Pages

  9. TUFFY® II

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.