Group: AMETEK
Catalog excerpts
Magnetrol ECLIPSE* 705 Guided Wave Radar Level Transmitter FOR HYGIENIC USE DESCRIPTION The Eclipse® 705 Transmitter is a loop-powered, 24 V DC I iquid-level transmitter based on the revolutionary Guided Wave Radar (GWR) technology. Encompassing a number of significant engineering accomplishments, this leading edge level transmitter is designed to provide measurement performance well beyond that of many traditional technologies, including “through-air” radar. The Eclipse® 705 offers enhanced reliability, as demonstrated by a Safe Failure Fraction of 91 %. Measures real «Level, Volume, Interfaced FEATURES * “Real Level”, measurement not affected by media variables eg. dielectrics, pressure, density, pH, viscosity, ... * Can measure reliably to very top of vessel and to the bottom of the probe. * Two-wire, intrinsically safe loop powered level transmitter. * 20-point custom strapping table for volumetric output. * Housing can be removed without depressurising the vessel. * Two-line, 8-character LCD and 3-button keypad. * Suitable design for CIP/SIP cleaning. * Integral or remote electronics. * Suited for SIL 2 / SIL 3 Loops (full FMEDA report and certificate available). * Designed to Bio Processing Equipment (BPE) standards. * The certificate of conformity includes certification of 'O'-rings, TFE, and PEEK as 21CFR-177 GRAS and USP <88> Class VI at 121 °C, and metallic material CMTR's and surface finish specification. APPLICATIONS MEDIA: From non conductive liquids up to water-based media (dielectric 1,9 - 100). VESSELS: Most process or storage vessels. CONDITIONS: All level measurement and control applications including process conditions exhibiting visible vapours, foam, surface agitation, bubbling or boiling, high fill/empty rates, low level and varying dielectric media or specific gravity. q /S fit mi# 13 BPE AGENCY APPROVALS Agency ® Foundation Fieldbus™ and Profibus PA™ units ® Consult factory for proper model numbers and classifications Worldwide level and flow solutions
Open the catalog to page 1Eclipse® Guided Wave Radar is based upon the technology of TDR (Time Domain Reflectometry). TDR utilises pulses of electromagnetic energy transmitted down a wave guide (probe). When a pulse reaches a liquid surface that has a higher dielectric constant than the air (εr of 1) in which it is traveling, the pulse is reflected. The travelling time of the pulse is measured via ultra high speed timing circuitry that provides an accurate measure of the liquid level. Principle of operation Reflected Pulse Initial Pulse signal propagation P A C T w a r e ™ P C S O F T WA R E P R O G R A M FDT...
Open the catalog to page 2P R O B E & H O U S I N G F E AT U R E S Stainless steel housing with probe Eclipse model 705 transmitter in a 304 stainless steel housing for use in a variety of hygienic applications. The probe has a 0,4 µm Ra (15 Ra) electropolished surface finish and is available with 3/4" through 3" TriClamp® process connections. Other process connections are available upon request. 1 1/2" Tri-Clamp® connection with bend Multiple bending allows the rod to be profiled to any tank shape. Measurement is possible down to the probe tip, eliminating the “dead” volume in the bottom of a tank that cannot usually...
Open the catalog to page 31. Turbulence The bottom of the probe should be stabilised if turbulence will cause a deflection of more than 75 mm at 3 m (3" at 10') of length. The probe should not make contact with the side wall of a metal tank. The use of a capture ring at the lowest point on the probe will prevent unwanted probe movement, while maintaining cleanability. 2. Nozzles: do not restrict the performance by ensuring the following: 1. Nozzle must be 19 mm (3/4") diameter (A) or larger. 2. Nozzle inside diameter (A) should be a to nozzle height (B). If this is not the case, it is recommended to adjust BLOCKING...
Open the catalog to page 4The model 705 transmitters are presently installed in a variety of media systems including bioreactors, fermenters, media storage, crystallisers, decanters, ultra filtration skid receivers, cook kettles, CIP systems, balance tanks, mixing tanks, storage tanks, etc. Buffers systems including: • primary mix tanks • hold tanks • day tanks • bulk tanks CIP systems including: • day tanks • bulk tanks • skid delivery tanks Tulip tank Utility systems including: • ammonia storage • CO2 storage • inlet water • dearator systems • condensate receivers • boiler drums • fuel oil storage • various sumps •...
Open the catalog to page 5Cable entry Integral Electronics Cable entry Remote Electronics ELECTRICAL WIRING Standard shielded twisted cable recommended. Galvanic Barrier (only needed for intrinsically safe units): Foundation Fieldbus™ / Profibus PA™: max. 17,5 V DC @ 380 mA
Open the catalog to page 6A complete measuring system consists of: 1. Eclipse 705 transmitter head/electronics 2. Eclipse 705 GWR probe 3. Free of charge: Eclipse 705 DTM (PACTware™) can be downloaded from www.magnetrol.com. 4. Option: MACTek Viator USB HART® interface: order code: 070-3004-002 1. Order code for ECLIPSE 705 transmitter head/electronics BASIC MODEl NUMBER Eclipse 705 guided wave radar transmitter 24 V DC, two wire loop powered 4-20 mA with HART® – standard electronics (SFF of 84,5 %) 4-20 mA with HART® – SIl enhanced electronics (SFF of 91 %) – certied Foundation Fieldbus™ communication Probus PA™...
Open the catalog to page 7Process Connection Probe Insertion Length Probe Insertion Length All except 3/4" Tri-Clamp® connection max. 6,10 m (240") NEUMO BioControl
Open the catalog to page 82. Order code for ECLIPSE 705 - hygienic GWR probe for liquids BASIC MODEl NUMBER Hygienic single rod with PTFE seal See mounting considerations on page 4 for ε ≥ 1,9 and < 10. r PROBE MATERIAl (0,4 µm Ra (15 Ra) electropolished surface nish) 316/316l (1.4401/1.4404) stainless steel Al-6XN stainless steel (UNS N08367) Hastelloy® C22 (2.4602) PROCESS CONNECTION - SIZE/TYPE 2 P N 3/4" Tri-Clamp® 3 P N 1" - 11/2" Tri-Clamp® 4 P N 2" Tri-Clamp® 9 P N 21/2" Tri-Clamp® 5 P N 3" Tri-Clamp® 6 P N 4" Tri-Clamp® minimum 30 cm (12") maximum 180 cm (72") for 3/4" process conn. size maximum 610 cm...
Open the catalog to page 9All Magnetrol - AMETEK catalogs and technical brochures
-
Interface In The Field
14 Pages
-
Emulsion In The Field
9 Pages
-
PRODUCT LINE CATALOGUE
106 Pages
-
Aurora® Magnetic Level Indicator
28 Pages
-
Atlas™ Magnetic Level Indicator
24 Pages
-
STEAM DRUM LEVEL MATTERS
1 Pages
-
INTERFACE IN THE FIELD
1 Pages
-
Echotel® 355
4 Pages
-
Echotel® 335
4 Pages
-
Power Generation
16 Pages
-
Petroleum Refining
16 Pages
-
Natural Gas Processing
12 Pages
-
Seal Pots
4 Pages
-
Mass Flow Measurement
12 Pages
-
Interface Level Measurement
8 Pages
-
Heat Rate Awareness
8 Pages
-
Ethylene Applications
8 Pages
-
Thermatel® TD1/TD2
16 Pages
-
Kotron® 082
4 Pages
-
Enhanced Jupiter®
16 Pages
-
GEMINI™
32 Pages
-
Aurora®
32 Pages
-
Atlas™
24 Pages
-
Horizon TM Model 704
8 Pages
-
Eclipse® Enhanced 705
8 Pages
-
Pneumatic Tuffy®
12 Pages
-
Models T5x & T6x
8 Pages
-
Models T20/T21
12 Pages
-
Series B73 and Series 75
12 Pages
-
Series 3
24 Pages
-
Model J52
2 Pages
-
Model B40
4 Pages
-
TUFFY® II
12 Pages
-
Digital E3 Modulevel®
12 Pages
-
Floating Roof Detection
16 Pages
-
APM Pneumatic Modulevel®
12 Pages
-
Flue Gas Desulferization
8 Pages
-
Energy Management
4 Pages
-
API 2350 Overfill Prevention
8 Pages
-
PULSAR ® R96
1 Pages
-
Water & Wastewater
12 Pages
-
Displacer Switches
20 Pages
-
Displacer Transmitters
4 Pages
-
Guided Wave Radar
12 Pages
-
Magnetic Level Indicators
12 Pages
-
Magnetostrictive
16 Pages
-
Pulse Burst Radar
8 Pages
-
Thermal Dispersion
12 Pages
-
Ultrasonic Contact
4 Pages
-
Vibrating Rod Switches
4 Pages
-
R Series High Temp Switch
12 Pages
-
Series K Pneumatic Switch
8 Pages
-
J Series Pneumatic Switch
8 Pages
-
Liquid Displacer Level Switches
16 Pages
-
Crude Oil Processing
8 Pages
-
Product Line Quick Reference
8 Pages