Group: AMETEK
Catalog excerpts
ECHOTEL® 355 Ultrasonic non contact transmitter for level, volume or open channel flow DESCRIPTION The Echotel® 355 is an integral mount, high performance ultrasonic non contact transmitter for liquid level, volume and open channel flow measurement. The electronics are housed in a single compartment cast aluminium or Lexan® housing. The intelligent electronics analyze the ultrasonic echo profile, apply temperature compensation, reject echoes from false targets, and then processes the true echo from the liquid surface. This results in an extremely reliable measurement even when application difficulties like turbulence and false echoes exist. FEATURES • 2-wire, intrinsically safe loop powered • Fast and easy configuration via 2 x 16 character display and 4-pushbutton keypad • False target rejection identifies true echo from liquid surface • Common tank shapes and 20-point custom table for volume calculations. • Flume/weir primary elements and generic equation for open channel flow. • Two 7-digit totalizers for flow: - resettable - continuous totalizer ® Consult factory for proper model numbers and classifications. APPLICATIONS • Open channel flow flumes and weirs • Paint, ink and solvent tanks • Chemical storage • Thick and viscous media • Batch and day tanks AGENCY APPROVALS Worldwide level and flow solutions
Open the catalog to page 1The level measurement is accomplished by emitting an ultrasonic pulse from the transducer face and measuring the travelling time between sending this pulse and its reflected echo from the liquid surface. Since the speed of sound is temperature dependant, the transducer also measures ambient temperature to compensate for the changing velocity. Measurement Range Calculations Ultrasonic non-contact measurement transmitters are typically rated for their maximum rangeability. Depending process conditions, their maximum range needs to be reduced for getting an optimal measuring result. Use below...
Open the catalog to page 2S E L E C T I O N D ATA 1. Order code for Echotel 355 transmitter 24 V DC 2-wire loop powered ultrasonic non contact transmitter with HART® 24 V DC 2-wire loop powered ultrasonic non contact transmitter without HART® Digital display and keypad MOUNTING / APPROVAL Integral mount, Weatherproof Integral mount, ATEX intrinsically safe Integral mount, ATEX flameproof enclosure (not available with Lexan® plastic housing) HOUSING / CABLE ENTRY Cast aluminium, 3/4" NPT cable entry (2 entries - 1 plugged) Cast aluminium, M20 x 1,5 cable entry (2 entries - 1 plugged) Lexan® plastic, 3/4" NPT cable...
Open the catalog to page 3The inside of the nozzle should be smooth. The inner rim at the end of the nozzle must be smooth and free of burrs. Standpipe 0 bytheRvA ISO-9001:2008 DNV Certification 0.V., THE NETHERLANDS QUALITY ASSURANCE - ISO 9001:2008 THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL® GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE DESIGN, THE CONSTRUCTION AND THE SERVICE OF CONTROLS. OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001:2008 AND OUR TOTAL COMPANY IS COMMITTED TO PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE. PRODUCT WARRANTY ALL...
Open the catalog to page 4All Magnetrol - AMETEK catalogs and technical brochures
-
Interface In The Field
14 Pages
-
Emulsion In The Field
9 Pages
-
PRODUCT LINE CATALOGUE
106 Pages
-
Aurora® Magnetic Level Indicator
28 Pages
-
Atlas™ Magnetic Level Indicator
24 Pages
-
STEAM DRUM LEVEL MATTERS
1 Pages
-
INTERFACE IN THE FIELD
1 Pages
-
Echotel® 335
4 Pages
-
Power Generation
16 Pages
-
Petroleum Refining
16 Pages
-
Natural Gas Processing
12 Pages
-
Seal Pots
4 Pages
-
Mass Flow Measurement
12 Pages
-
Interface Level Measurement
8 Pages
-
Heat Rate Awareness
8 Pages
-
Ethylene Applications
8 Pages
-
Thermatel® TD1/TD2
16 Pages
-
Kotron® 082
4 Pages
-
Enhanced Jupiter®
16 Pages
-
GEMINI™
32 Pages
-
Aurora®
32 Pages
-
Atlas™
24 Pages
-
Horizon TM Model 704
8 Pages
-
Eclipse® Enhanced 705 Hygienic
12 Pages
-
Eclipse® Enhanced 705
8 Pages
-
Pneumatic Tuffy®
12 Pages
-
Models T5x & T6x
8 Pages
-
Models T20/T21
12 Pages
-
Series B73 and Series 75
12 Pages
-
Series 3
24 Pages
-
Model J52
2 Pages
-
Model B40
4 Pages
-
TUFFY® II
12 Pages
-
Digital E3 Modulevel®
12 Pages
-
Floating Roof Detection
16 Pages
-
APM Pneumatic Modulevel®
12 Pages
-
Flue Gas Desulferization
8 Pages
-
Energy Management
4 Pages
-
API 2350 Overfill Prevention
8 Pages
-
PULSAR ® R96
1 Pages
-
Water & Wastewater
12 Pages
-
Displacer Switches
20 Pages
-
Displacer Transmitters
4 Pages
-
Guided Wave Radar
12 Pages
-
Magnetic Level Indicators
12 Pages
-
Magnetostrictive
16 Pages
-
Pulse Burst Radar
8 Pages
-
Thermal Dispersion
12 Pages
-
Ultrasonic Contact
4 Pages
-
Vibrating Rod Switches
4 Pages
-
R Series High Temp Switch
12 Pages
-
Series K Pneumatic Switch
8 Pages
-
J Series Pneumatic Switch
8 Pages
-
Liquid Displacer Level Switches
16 Pages
-
Crude Oil Processing
8 Pages
-
Product Line Quick Reference
8 Pages