Group: AMETEK
Catalog excerpts
Get one thing straight Digital E3 MODULEVEL Liquid Level Displacer Transmitter Outstanding output stability, structural integrity and ease of use make range spring technology a better level control solution than torque tubes.
Open the catalog to page 1Avoid the twists and turns of torque tube technology, which can’t equal the Electronics Enclosure performance, durability and ease of use of a range spring. The E3 MODULEVEL linear variable differential transformer (LVDT) transmitter, with range spring technology, is the straightforward choice for accurate,LVDT reliable liquid level Moving measurement and control. LVDT Core Printed Circuit Board • Changing buoyancy forces caused by liquid level variation act upon the range-spring-supported displacer, causing vertical motion of the core within a linear variable differential transformer...
Open the catalog to page 2Pressure Boundary Integrity Electronics Enclosure LVDT Enclosing Tube Wall Moving LVDT Core • The enclosing tube that forms the pressure boundary seal of the E3 MODULEVEL is at least 0.035” thick, compared to the torque tube’s 0.01” thickness. • Torsion of the torque tube may result in fatigue failure of this pressure-retaining component, as well as opportunity for accelerated corrosion as a result of the shear stresses induced in the tube. The static-pressure-retaining enclosing tube on the E3 MODULEVEL is not susceptible to either of these failure effects. Printed Circuit Board Display...
Open the catalog to page 3Digital E3 Modulevel® Liquid Level Displacer Transmitter Features • SIL 2 suitable with the highest Safety Failure Fraction (SFF) of any displacer transmitter at 92.3%. • No calibration required; configuration only. • Available with 4 – 20 mA and HART® 6.x with PACTware™ PC software and the Field Device Tool (FDT); AMS ready. • FOUNDATION fieldbus™ option with PID block and Link Active Scheduler (LAS) capability. • Comprehensive diagnostics with faults, warnings and status history. • Range spring suppresses effects of turbulence to produce stable output signal. • Suitable for process...
Open the catalog to page 4All Magnetrol - AMETEK catalogs and technical brochures
-
Interface In The Field
14 Pages
-
Emulsion In The Field
9 Pages
-
PRODUCT LINE CATALOGUE
106 Pages
-
Aurora® Magnetic Level Indicator
28 Pages
-
Atlas™ Magnetic Level Indicator
24 Pages
-
STEAM DRUM LEVEL MATTERS
1 Pages
-
INTERFACE IN THE FIELD
1 Pages
-
Echotel® 355
4 Pages
-
Echotel® 335
4 Pages
-
Power Generation
16 Pages
-
Petroleum Refining
16 Pages
-
Natural Gas Processing
12 Pages
-
Seal Pots
4 Pages
-
Mass Flow Measurement
12 Pages
-
Interface Level Measurement
8 Pages
-
Heat Rate Awareness
8 Pages
-
Ethylene Applications
8 Pages
-
Thermatel® TD1/TD2
16 Pages
-
Kotron® 082
4 Pages
-
Enhanced Jupiter®
16 Pages
-
GEMINI™
32 Pages
-
Aurora®
32 Pages
-
Atlas™
24 Pages
-
Horizon TM Model 704
8 Pages
-
Eclipse® Enhanced 705 Hygienic
12 Pages
-
Eclipse® Enhanced 705
8 Pages
-
Pneumatic Tuffy®
12 Pages
-
Models T5x & T6x
8 Pages
-
Models T20/T21
12 Pages
-
Series B73 and Series 75
12 Pages
-
Series 3
24 Pages
-
Model J52
2 Pages
-
Model B40
4 Pages
-
TUFFY® II
12 Pages
-
Digital E3 Modulevel®
12 Pages
-
Floating Roof Detection
16 Pages
-
APM Pneumatic Modulevel®
12 Pages
-
Flue Gas Desulferization
8 Pages
-
Energy Management
4 Pages
-
API 2350 Overfill Prevention
8 Pages
-
PULSAR ® R96
1 Pages
-
Water & Wastewater
12 Pages
-
Displacer Switches
20 Pages
-
Guided Wave Radar
12 Pages
-
Magnetic Level Indicators
12 Pages
-
Magnetostrictive
16 Pages
-
Pulse Burst Radar
8 Pages
-
Thermal Dispersion
12 Pages
-
Ultrasonic Contact
4 Pages
-
Vibrating Rod Switches
4 Pages
-
R Series High Temp Switch
12 Pages
-
Series K Pneumatic Switch
8 Pages
-
J Series Pneumatic Switch
8 Pages
-
Liquid Displacer Level Switches
16 Pages
-
Crude Oil Processing
8 Pages
-
Product Line Quick Reference
8 Pages