Modulevel® Pneumatic and APM Liquid Level Control Modulevel pneumatic liquid level controls are displacement actuated level sensors that provide output signals in direct proportion to changes in liquid level. Simple modular design and the Magnetrol proven magnetic coupling make Modulevel controls versatile, highly stable, vibration resistant and adaptable to extremes in temperature and pressure. Features • Standard models handle service temperatures from -150 to +700 °F (-101 to +371 °C) and pressure to 4265 PSIG (318 Bar). • Stable output signal is unaffected by surface turbulence. Prevents control valve “hunting” and extends valve life. • Controller head may be removed without disturbing pressure boundary. Permits service or replacement without shutdown of process. • Simple calibration prior to installation, by substituting weights for displacer or by controller head calibration with displacer. • Accurate output signal provided over a wide specific gravity range. • Controller head rotates 360°, simplifies pneumatic piping hookup. • 316 SS displacer and trim. Inconel & 316SS range springs. (Consult factory for Hastelloy displacer.) • Easily calibrated without moving tank liquid level, for reduced installation time and cost. • Pilot relay provides a 4 to 1 amplification of pilot pressure signal to speed value response. • Built-in visual level indicator is independent of air supply. • Optional pneumatic-tocurrent interface transducer for use in electronic control applications. • Optional proportional plus integral control. • Optional differential gap (on-off) control. • Optional High-Low electronic alarm signal provides inexpensive backup alarm. • Fabricated construction. Applications Modulevel pneumatic liquid level controls are widely used in utility power generation, chemical and petroleum processing operations, such as: • Steam generator feedwater heater regulation • Vent gas scrubber level control • Fractionating column level transmitter • Drip pot condensate level control • Ethanolamine level transmitter • Flash tank level transmitter • Boiler lev
Open the catalog to page 1Zero adjustment The key elements of the Modulevel pneumatic control are the magnetic coupling, which allows the controller to be mechanically isolated from the sealed sensing unit; the range spring, which dampens the action of the displacer; and the controller head, which provides a modulated pneumatic signal in direct proportion to the input from the vertical motion of the displacer. As the liquid level in the vessel increases or decreases, the buoyant displacer rises or falls. This motion, dampened by the action of the range spring to prevent response to the rapid fluctuations of turbulence,...
Open the catalog to page 2Mounting arrangements Modulevel® pneumatic instruments Flanged top P51, P61 and P62 displacer models Modulevel pneumatic instruments are available in a variety of functions and styles to handle different application requirements. For mounting on top of the tank, flanged top models are available. They are used extensively in interface control applications where non-standard size displacers become necessary. An adjustable stainless steel displacer suspension cable is also available. Top mounting models are directly interchangeable with the external cage models. Choose from carbon steel or stainless...
Open the catalog to page 3Expedite ship plan (ESP) Model number construction Many standard Modulevel pneumatic level controls are available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP). Models covered by ESP service are conveniently color coded in the selection data charts which follow. To take advantage of ESP, simply match color coded model number codes and options (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volue orders as well as other...
Open the catalog to page 4Model number construction Selection data Modulevel controls are identified by a ten-digit alphanumeric model numbering system. The model number describes model configuration, materials of construction, level ranges and other options vital to the performance and function of the instrument. Example: P51-5H6A-PAA Mounting & materials 1 of construction Specific gravity 2 and temperature 3 Tank connection 4 Level range 5 Pneumatic instrument High pressure flanged cage displacer models 1 Mounting and materials of construction Model ➀ External Flanged Cage Body Material Carbon Steel Mounting Connection...
Open the catalog to page 5Selection data Model number construction Modulevel controls are identified by a ten digit alphanumeric model numbering system. The model number describes model configuration, materials of construction, level ranges and other options vital to the performance and function of the instrument. Example: P71-1C9A-PAA Mounting Arrangement Body Material External Sealed Cage Carbon Steel Mounting & materials 1 of construction 1 Mounting and materials of construction Style *For 600 lb. pressure rating, refer to chart at right. 4 Level range/displacer diameter Code Mounting Connection Code NPT, socket weld,...
Open the catalog to page 6Selection data Model number construction Modulevel controls are identified by a ten-digit alphanumeric model numbering system. The model number describes model configuration, materials of construction, level ranges and other options vital to the performance and function of the instrument. Example: P68-2F2A-PAJ 1 Mounting and materials of construction Mounting Arrangement Body Material Carbon Steel Mounting & materials 1 of construction Tank connection 3 & level range Float & Trim *Maximum pressure rating with 600 lb. flange is 800 psi at 100° F. 2 Specific gravity and temperature Liquid Specific...
Open the catalog to page 7Dimensional specifications NOTE: Controller head may be rotated through 360°. 1/4" NPT x 2.00 (51) long minimum nipple required 1/4" NPT x 2.00 (51) long minimum nipple required Optional nipple mounted filter regulator (4) 1/4" NPT Optional nipple mounted filter regulator 6.50 (165) ANSI standard flange Level range Level range Optional 3/4" NPT gauge glass tapping (2) 1 1/2" or 2" NPT or socket weld (2) 1 1/2" or 2" ANSI standard flange P61 and P62 Series Top Mounting 150, 300, 600 lb. Class P63 and P64 Series with Side/Bottom Connections 150, 300, 600 lb. Class Swing radius Outlet Size Outlet...
Open the catalog to page 812 Pages
12 Pages
12 Pages
16 Pages
8 Pages
12 Pages
14 Pages
9 Pages
106 Pages
28 Pages
24 Pages
4 Pages
1 Page
1 Page
16 Pages
16 Pages
4 Pages
12 Pages
8 Pages
8 Pages
32 Pages
12 Pages
8 Pages
12 Pages
12 Pages
24 Pages
2 Pages
4 Pages
16 Pages
20 Pages
8 Pages
4 Pages
8 Pages
1 Page
12 Pages
4 Pages
12 Pages
12 Pages
12 Pages
4 Pages
12 Pages
8 Pages
8 Pages
16 Pages
8 Pages
8 Pages